{"id":98169,"date":"2026-05-26T13:30:00","date_gmt":"2026-05-26T05:30:00","guid":{"rendered":"https:\/\/machinedquartz.com\/?page_id=98169"},"modified":"2026-06-11T09:49:33","modified_gmt":"2026-06-11T01:49:33","slug":"z-mass-spektrophotometer-kuevetten","status":"publish","type":"page","link":"https:\/\/machinedquartz.com\/de\/z-mass-spektrophotometer-kuevetten\/","title":{"rendered":"Z-Ma\u00df von Spektrophotometer-K\u00fcvetten"},"content":{"rendered":"\n<style>\n\/* \u2500\u2500 Layout \u2500\u2500 *\/\n.klb-page-title{display:none!important}\n.zd{max-width:920px;margin:0 auto;padding:0 20px;font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',sans-serif;color:#1a1a2e}\n\n\/* \u2500\u2500 Hero \u2500\u2500 *\/\n.zd-hero{background:linear-gradient(135deg,#1a2a6c 0%,#233a95 60%,#1e4db7 100%);border-radius:16px;padding:56px 40px 44px;margin-bottom:40px;text-align:center}\n.zd-hero-eye{font-size:11px;font-weight:700;letter-spacing:2.5px;text-transform:uppercase;color:#a5c0ff;margin-bottom:14px}\n.zd-hero h1{font-size:clamp(24px,3.8vw,42px);font-weight:800;color:#fff;margin:0 0 16px;line-height:1.2}\n.zd-hero-sub{font-size:16px;color:rgba(255,255,255,.8);margin:0 auto;max-width:600px;line-height:1.6}\n.zd-stats{display:grid;grid-template-columns:repeat(3,1fr);gap:0;background:rgba(255,255,255,.1);border-radius:10px;margin-top:32px}\n.zd-stat{padding:18px 12px;border-right:1px solid rgba(255,255,255,.12);text-align:center}\n.zd-stat:last-child{border-right:none}\n.zd-stat-num{font-size:24px;font-weight:800;color:#fff}\n.zd-stat-label{font-size:11px;color:#a5c0ff;margin-top:2px}\n\n\/* \u2500\u2500 GEO definition block \u2500\u2500 *\/\n.zd-def{border-left:4px solid #233a95;background:#f0f4ff;border-radius:0 10px 10px 0;padding:18px 22px;margin-bottom:36px;font-size:14px;line-height:1.7;color:#333}\n.zd-def strong{color:#1a2a6c}\n\n\/* \u2500\u2500 Section label \u2500\u2500 *\/\n.zd-label{font-size:11px;font-weight:700;letter-spacing:2px;text-transform:uppercase;color:#233a95;margin-bottom:10px}\n\n\/* \u2500\u2500 SVG diagram wrapper \u2500\u2500 *\/\n.zd-diagram{background:#f7f8fc;border-radius:12px;padding:28px;margin-bottom:36px;text-align:center}\n.zd-diagram figcaption{font-size:12px;color:#666;margin-top:12px;line-height:1.5}\n\n\/* \u2500\u2500 Z value comparison cards \u2500\u2500 *\/\n.zd-compare{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin-bottom:40px}\n.zd-card{background:#f7f8fc;border-radius:12px;padding:28px;border-top:4px solid #233a95;transition:background .2s,transform .15s}\n.zd-card:hover{background:#233a95;transform:translateY(-3px)}\n.zd-card h3{font-size:18px;font-weight:700;color:#1a1a2e;margin:0 0 8px;transition:color .2s}\n.zd-card:hover h3{color:#fff}\n.zd-card .zd-card-z{font-size:36px;font-weight:800;color:#233a95;margin-bottom:10px;transition:color .2s}\n.zd-card:hover .zd-card-z{color:#a5c0ff}\n.zd-card p,.zd-card li{font-size:14px;color:#555;line-height:1.7;transition:color .2s}\n.zd-card:hover p,.zd-card:hover li{color:rgba(255,255,255,.85)}\n.zd-card ul{margin:10px 0 0;padding-left:18px}\n.zd-card .zd-badge{display:inline-block;font-size:11px;font-weight:600;background:#233a95;color:#fff;border-radius:20px;padding:3px 10px;margin-bottom:12px;transition:background .2s}\n.zd-card:hover .zd-badge{background:rgba(255,255,255,.2)}\n.zd-card.warn{border-top-color:#e67e22}\n.zd-card.warn .zd-card-z{color:#e67e22}\n.zd-card.warn .zd-badge{background:#e67e22}\n\n\/* \u2500\u2500 Why it matters \u2500\u2500 *\/\n.zd-warn-box{background:#fff8f0;border:1.5px solid #e67e22;border-radius:10px;padding:20px 24px;margin-bottom:36px;font-size:14px;line-height:1.7}\n.zd-warn-box strong{color:#c0392b}\n\n\/* \u2500\u2500 Lookup tool (preserved) \u2500\u2500 *\/\n.zp{max-width:100%;font-family:inherit}\n.zp-tool{background:#fff;border:1px solid #e0e4f0;border-radius:12px;padding:26px 30px;margin-bottom:30px;box-shadow:0 2px 12px rgba(35,58,149,.07)}\n.zp-row{display:grid;grid-template-columns:1fr 1fr auto;gap:14px;align-items:end;margin-bottom:16px}.zp-field{display:flex;flex-direction:column;justify-content:flex-end;min-height:64px}\n.zp-field label{display:block;font-size:11px;font-weight:700;letter-spacing:1px;text-transform:uppercase;color:#233a95;margin-bottom:6px;height:16px;line-height:16px}\n.zp-field select,.zp-field input{width:100%;padding:0 14px;border:1.5px solid #d0d8f0;border-radius:8px;font-size:14px;color:#1a1a2e;background:#fff;transition:border-color .2s;-webkit-appearance:none;appearance:none;box-sizing:border-box;height:42px;line-height:42px}.zp-field select{margin-top:0;margin-bottom:0}\n.zp-toggle-btn{background:none;border:1.5px solid #233a95;color:#233a95;border-radius:20px;padding:7px 22px;font-size:13px;font-weight:600;cursor:pointer;transition:all .2s}\n.zp-toggle-btn:hover{background:#233a95;color:#fff}\n.zp-field select:focus,.zp-field input:focus{outline:none;border-color:#233a95}\n.zp-btn{background:#233a95;color:#fff;border:none;border-radius:8px;padding:11px 26px;font-size:14px;font-weight:600;cursor:pointer;white-space:nowrap;transition:background .2s;height:42px;align-self:end;margin-top:22px}\n.zp-btn:hover{background:#1a2a6c}\n.zp-hint{font-size:12px;color:#888;min-height:18px;margin-bottom:8px}\n.zp-res{display:none;background:#f0f4ff;border:1.5px solid #233a95;border-radius:10px;padding:20px 24px;margin-top:4px}\n.zp-res.show{display:block}\n.zp-res.warn{background:#fff8f0;border-color:#e67e22}\n.zp-res.na{background:#f8f8f8;border-color:#ccc}\n.res-hd{display:flex;align-items:center;gap:14px;margin-bottom:14px;flex-wrap:wrap}\n.res-badge{font-size:26px;font-weight:800;color:#233a95;background:#fff;border:2px solid #233a95;border-radius:8px;padding:5px 16px;min-width:90px;text-align:center}\n.res-badge.warn{color:#e67e22;border-color:#e67e22}\n.res-name{font-weight:700;font-size:16px}\n.res-sub{font-size:13px;color:#666;margin-top:2px}\n.cc-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(180px,1fr));gap:10px;margin-top:12px}\n.cc{background:#fff;border-radius:8px;padding:12px 14px;border-left:3px solid #ccc;font-size:12px}\n.cc.ok{border-left-color:#2ecc71}.cc.warn{border-left-color:#e67e22}.cc.no{border-left-color:#e74c3c}\n.cc-t{font-weight:600;margin-bottom:3px}\n.cc-d{color:#666;margin-bottom:6px;font-size:11px}\n.cc-tag{font-size:10px;font-weight:600;padding:2px 7px;border-radius:10px;display:inline-block}\n.cc-tag.ok{background:#e8fdf0;color:#27ae60}.cc-tag.warn{background:#fff3e0;color:#e67e22}.cc-tag.no{background:#fdecea;color:#e74c3c}\n.zp-tip{display:none;background:#fff3e0;border:1px solid #f0a500;border-radius:8px;padding:12px 16px;margin-top:10px;font-size:13px;color:#7a4f00;line-height:1.6}\n.zp-nores{display:none;padding:14px;background:#fafafa;border-radius:8px;font-size:14px;color:#555;text-align:center}\n\/* Filter bar *\/\n.fb{display:flex;flex-wrap:wrap;gap:8px;margin-bottom:14px}\n.fb-btn{padding:6px 14px;border:1.5px solid #d0d8f0;border-radius:20px;font-size:12px;font-weight:600;cursor:pointer;background:#fff;color:#555;transition:all .2s}\n.fb-btn:hover{border-color:#233a95;color:#233a95}\n.fb-btn.active{background:#233a95;color:#fff;border-color:#233a95}\n\/* Table *\/\ntable.zt{width:100%;border-collapse:collapse;font-size:13px;margin-top:4px}\ntable.zt th{background:#f0f4ff;color:#233a95;font-weight:700;padding:9px 12px;text-align:left;border-bottom:2px solid #d0d8f0}\ntable.zt td{padding:8px 12px;border-bottom:1px solid #eee;vertical-align:middle}\ntable.zt tr:hover td{background:#f7f9ff}\n.zv{font-weight:700;color:#233a95}.zv.w{color:#e67e22}\n.zna{color:#aaa;font-style:italic}\n.bt{display:inline-block;font-size:10px;font-weight:600;padding:2px 8px;border-radius:10px}\n.bt-uv{background:#e8f0fe;color:#1a5cd8}.bt-nir{background:#f3e8ff;color:#7c3aed}.bt-fl{background:#fef9e7;color:#b8860b}\n.zt-wrap{overflow-x:auto}\n\n\/* \u2500\u2500 How-to steps \u2500\u2500 *\/\n.zd-steps{display:grid;grid-template-columns:repeat(3,1fr);gap:18px;margin-bottom:40px}\n.zd-step{background:#f7f8fc;border-radius:10px;padding:24px;border-top:3px solid #233a95;transition:background .2s,transform .15s}\n.zd-step:hover{background:#233a95;transform:translateY(-3px)}\n.zd-step-num{font-size:28px;font-weight:800;color:#233a95;margin-bottom:8px;transition:color .2s}\n.zd-step:hover .zd-step-num{color:#a5c0ff}\n.zd-step h3{font-size:15px;font-weight:700;color:#1a1a2e;margin:0 0 8px;transition:color .2s}\n.zd-step:hover h3{color:#fff}\n.zd-step p{font-size:13px;color:#555;line-height:1.6;margin:0;transition:color .2s}\n.zd-step:hover p{color:rgba(255,255,255,.85)}\n\n\/* \u2500\u2500 Cuvette types table \u2500\u2500 *\/\n.zd-type-table{width:100%;border-collapse:collapse;font-size:14px;margin-bottom:36px}\n.zd-type-table th{background:#f0f4ff;color:#233a95;font-weight:700;padding:10px 14px;text-align:left;border-bottom:2px solid #d0d8f0}\n.zd-type-table td{padding:10px 14px;border-bottom:1px solid #eee;vertical-align:top;line-height:1.5}\n.zd-type-table tr:hover td{background:#f7f9ff}\n.zd-zbadge{display:inline-block;font-size:11px;font-weight:700;padding:2px 9px;border-radius:10px;white-space:nowrap}\n.zd-zbadge.z15{background:#e8f0fe;color:#1a5cd8}\n.zd-zbadge.z85{background:#fff3e0;color:#e67e22}\n.zd-zbadge.both{background:#f3e8ff;color:#7c3aed}\n\n\/* \u2500\u2500 Key facts (GEO) \u2500\u2500 *\/\n.zd-facts{background:#fffdf0;border:1.5px solid #f0c040;border-radius:10px;padding:20px 24px;margin-bottom:36px}\n.zd-facts h3{font-size:13px;font-weight:700;color:#7a5c00;letter-spacing:1px;text-transform:uppercase;margin:0 0 12px}\n.zd-facts ul{margin:0;padding-left:20px;font-size:14px;color:#444;line-height:1.8}\n\n\/* \u2500\u2500 FAQ \u2500\u2500 *\/\n.zd-faq-item{border-bottom:1px solid #eee}\n.zd-faq-q{display:flex;justify-content:space-between;align-items:center;padding:16px 0;cursor:pointer;font-weight:600;font-size:15px;color:#1a1a2e}\n.zd-faq-q:hover{color:#233a95}\n.zd-faq-icon{font-size:20px;color:#233a95;transition:transform .3s;flex-shrink:0;margin-left:12px}\n.zd-faq-item.open .zd-faq-icon{transform:rotate(45deg)}\n.zd-faq-a{max-height:0;overflow:hidden;transition:max-height .3s ease}\n.zd-faq-item.open .zd-faq-a{max-height:400px;padding-bottom:16px}\n.zd-faq-a p{font-size:14px;color:#444;line-height:1.7;margin:0}\n\n\/* \u2500\u2500 CTA \u2500\u2500 *\/\n.zd-cta{background:linear-gradient(135deg,#1a2a6c 0%,#233a95 100%);border-radius:14px;padding:40px;text-align:center;margin-bottom:40px}\n.zd-cta h2{color:#fff;font-size:22px;margin:0 0 10px}\n.zd-cta p{color:rgba(255,255,255,.8);font-size:14px;margin:0 0 20px}\n.zd-cta-btns{display:flex;gap:12px;justify-content:center;flex-wrap:wrap}\n.zd-cta-btn{padding:12px 28px;border-radius:8px;font-size:14px;font-weight:600;text-decoration:none;transition:opacity .2s}\n.zd-cta-btn.primary{background:#fff;color:#233a95}\n.zd-cta-btn.secondary{background:rgba(255,255,255,.15);color:#fff;border:1.5px solid rgba(255,255,255,.4)}\n.zd-cta-btn:hover{opacity:.88}\n\n\/* \u2500\u2500 Responsive \u2500\u2500 *\/\n@media(max-width:680px){\n  .zd-hero{padding:36px 20px 28px}\n  .zd-stats{grid-template-columns:1fr 1fr}\n  .zd-compare{grid-template-columns:1fr}\n  .zd-steps{grid-template-columns:1fr}\n  .zp-row{grid-template-columns:1fr;grid-template-rows:auto auto auto}\n}\n<\/style>\n\n<div class=\"zd\">\n\n<!-- HERO -->\n<div class=\"zd-hero\">\n  <p class=\"zd-hero-eye\">K\u00fcvetten-Kompatibilit\u00e4tsleitfaden<\/p>\n  <p class=\"zd-hero h1\" style=\"font-size:clamp(24px,3.8vw,42px);font-weight:800;color:#fff;margin:0 0 16px;line-height:1.2\">Z-Ma\u00df von Spektrophotometer-K\u00fcvetten<\/p>\n<p style=\"background:#f0f4fc !important; border-left:3px solid #233a95; padding:10px 14px; border-radius:4px; font-size:14px; color:#1a1a2e !important;\">\ud83d\udd27 <strong>Brauchen Sie eine K\u00fcvette, die sich zerlegen l\u00e4sst?<\/strong> Siehe den <a href=\"https:\/\/machinedquartz.com\/de\/zerlegbare-kuevetten-leitfaden\/\">Leitfaden f\u00fcr zerlegbare K\u00fcvetten<\/a> : abnehmbare Quarzk\u00fcvetten (0,5\/1\/2 mm), plus DIY-Mittel-IR-K\u00fcvetten mit CaF\u2082- oder Saphirfenstern.<\/p>\n\n<p style=\"background:#f0f4fc !important; border-left:3px solid #233a95; padding:10px 14px; border-radius:4px; font-size:14px; color:#1a1a2e !important;\">\ud83d\udce1 <strong>Arbeiten Sie im NIR oder IR?<\/strong> Siehe den <a href=\"https:\/\/machinedquartz.com\/de\/quarz-ir-kuevetten-leitfaden\/\">Quarz-IR-K\u00fcvetten-Leitfaden<\/a> : Bereich 190\u20132500 nm, Schichtdicken-Tipps f\u00fcr Wasserbanden und Fertigungswahl.<\/p>\n\n<p style=\"background:#f0f4fc; border-left:3px solid #233a95; padding:10px 14px; border-radius:4px; font-size:14px;\">\ud83d\udd2c <strong>Arbeiten Sie mit winzigen Proben?<\/strong> Der <a href=\"https:\/\/machinedquartz.com\/de\/mikrokuevetten-leitfaden\/\">Mikrok\u00fcvetten-Leitfaden<\/a> deckt Halbmikro-, Sub-Mikro- und Ultra-Mikro-Klassen (5\u2013200 \u00b5L), Aperturgeometrie, Z-Ma\u00df und Pipettiergenauigkeit ab.<\/p>\n\n<p style=\"background:#f0f4fc; border-left:3px solid #233a95; padding:10px 14px; border-radius:4px; font-size:14px;\">\ud83e\uddfc <strong>M\u00fcssen Sie diese K\u00fcvetten reinigen?<\/strong> Siehe den <a href=\"https:\/\/machinedquartz.com\/de\/kuevetten-reinigungsprotokoll\/\">K\u00fcvetten-Reinigungsprotokoll<\/a> : 10 Reinigungsmittel, 6 Analytf\u00e4lle, t\u00e4gliche & Tiefenreinigungsschritte.<\/p>\n\n  <p class=\"zd-hero-sub\">Die Strahlh\u00f6hen-Spezifikation, die bestimmt, ob Ihre K\u00fcvette in Ihrem Ger\u00e4t funktioniert, und warum ein Fehler hier gar kein Signal bedeutet.<\/p>\n  <div class=\"zd-stats\">\n    <div class=\"zd-stat\"><div class=\"zd-stat-num\">15 mm<\/div><div class=\"zd-stat-label\">Standard-Z-H\u00f6he<\/div><\/div>\n    <div class=\"zd-stat\"><div class=\"zd-stat-num\">8,5 mm<\/div><div class=\"zd-stat-label\">Beckman \/ Eppendorf Z-H\u00f6he<\/div><\/div>\n    <div class=\"zd-stat\"><div class=\"zd-stat-num\">154+<\/div><div class=\"zd-stat-label\">Ger\u00e4te in der Datenbank<\/div><\/div>\n  <\/div>\n<\/div>\n\n<!-- GEO DEFINITION BLOCK -->\n<div class=\"zd-def\">\n  <strong>Was ist das Z-Ma\u00df?<\/strong> Das Z-Ma\u00df (auch Z-H\u00f6he oder Strahlh\u00f6he genannt) eines Spektrophotometers ist der vertikale Abstand vom Boden des K\u00fcvettenhalters bis zum Zentrum des Lichtstrahls, gemessen in Millimetern. Die meisten UV-Vis-Ger\u00e4te nutzen ein Z-Ma\u00df von <strong>15 mm<\/strong>. Eine Gruppe von Beckman-DU-, Eppendorf- und klinischen Ger\u00e4ten nutzt <strong>8,5 mm<\/strong>. Eine K\u00fcvette muss f\u00fcr das korrekte Z-Ma\u00df ausgelegt sein; sonst l\u00e4uft der Lichtstrahl \u00fcber oder unter dem optischen Fenster und es wird kein Absorptionssignal erfasst.\n<\/div>\n\n<!-- SECTION 1: WHAT IS Z DIMENSION -->\n<div style=\"margin-bottom:40px\">\n  <p class=\"zd-label\">Grundlagen<\/p>\n  <h2 style=\"font-size:24px;font-weight:700;color:#1a1a2e;margin:0 0 16px\">Was ist das Z-Ma\u00df in der Spektrophotometrie?<\/h2>\n  <p style=\"font-size:15px;line-height:1.8;color:#333;margin-bottom:16px\">Wenn ein UV-Vis- oder Fluoreszenz-Spektrophotometer arbeitet, sendet es einen Lichtstrahl horizontal durch die K\u00fcvette. Dieser Strahl l\u00e4uft in einer festen H\u00f6he \u00fcber der Grundplatte des Ger\u00e4ts, und diese H\u00f6he ist das <strong>Z-Dimension (Z-Ma\u00df)<\/strong>, typischerweise in Millimetern ausgedr\u00fcckt.<\/p>\n  <p style=\"font-size:15px;line-height:1.8;color:#333;margin-bottom:16px\">Die K\u00fcvette muss ihr optisches Fenster genau auf dieser H\u00f6he positionieren. Stimmt der Z-Wert der K\u00fcvette nicht mit dem Ger\u00e4t \u00fcberein, verfehlt der Strahl das Fenster ganz oder erfasst nur die Kante des Glases, was kein Signal, ein drastisch reduziertes Signal oder erratisches Basislinienrauschen erzeugt, das schwer zu diagnostizieren ist.<\/p>\n  <p style=\"font-size:15px;line-height:1.8;color:#333;margin-bottom:20px\">Das Z-Ma\u00df unterscheidet sich von der Schichtdicke (dem horizontalen Weg, den das Licht durch die Probe zur\u00fccklegt). Eine K\u00fcvette mit 10 mm Schichtdicke kann in Z=15 mm oder Z=8,5 mm Ausf\u00fchrung gefertigt werden: Sie sehen \u00e4u\u00dferlich fast identisch aus, sind aber zwischen Ger\u00e4tetypen nicht austauschbar.<\/p>\n\n  <!-- SVG diagram: Z dimension illustration -->\n  <div class=\"zd-diagram\">\n    <svg viewBox=\"0 0 700 260\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" style=\"max-width:620px;width:100%\">\n      <!-- Background -->\n      <rect width=\"700\" height=\"260\" fill=\"#f7f8fc\" rx=\"10\"\/>\n      <!-- Instrument base plate -->\n      <rect x=\"40\" y=\"200\" width=\"620\" height=\"16\" fill=\"#ccd3e8\" rx=\"3\"\/>\n      <text x=\"350\" y=\"230\" text-anchor=\"middle\" font-size=\"11\" fill=\"#666\" font-family=\"sans-serif\">Ger\u00e4te-Grundplatte<\/text>\n      <!-- Cuvette body -->\n      <rect x=\"295\" y=\"80\" width=\"110\" height=\"125\" fill=\"#d6e4f7\" stroke=\"#233a95\" stroke-width=\"2\" rx=\"3\"\/>\n      <!-- Optical window highlight -->\n      <rect x=\"295\" y=\"118\" width=\"110\" height=\"40\" fill=\"rgba(35,58,149,0.15)\" stroke=\"#233a95\" stroke-width=\"1.5\" stroke-dasharray=\"4,2\"\/>\n      <text x=\"350\" y=\"142\" text-anchor=\"middle\" font-size=\"11\" fill=\"#233a95\" font-family=\"sans-serif\" font-weight=\"600\">Optisches Fenster<\/text>\n      <!-- Light beam -->\n      <line x1=\"40\" y1=\"138\" x2=\"285\" y2=\"138\" stroke=\"#f39c12\" stroke-width=\"3\"\/>\n      <polygon points=\"285,132 300,138 285,144\" fill=\"#f39c12\"\/>\n      <line x1=\"415\" y1=\"138\" x2=\"650\" y2=\"138\" stroke=\"#f39c12\" stroke-width=\"3\"\/>\n      <text x=\"100\" y=\"128\" font-size=\"12\" fill=\"#c0730a\" font-family=\"sans-serif\" font-weight=\"600\">Lichtstrahl<\/text>\n      <!-- Z dimension arrow -->\n      <line x1=\"240\" y1=\"200\" x2=\"240\" y2=\"138\" stroke=\"#e74c3c\" stroke-width=\"2\"\/>\n      <polygon points=\"234,142 240,128 246,142\" fill=\"#e74c3c\"\/>\n      <polygon points=\"234,196 240,210 246,196\" fill=\"#e74c3c\"\/>\n      <text x=\"225\" y=\"175\" text-anchor=\"middle\" font-size=\"13\" fill=\"#e74c3c\" font-family=\"sans-serif\" font-weight=\"700\">Z<\/text>\n      <!-- Z value label -->\n      <rect x=\"168\" y=\"160\" width=\"46\" height=\"22\" fill=\"#e74c3c\" rx=\"4\"\/>\n      <text x=\"191\" y=\"175\" text-anchor=\"middle\" font-size=\"12\" fill=\"#fff\" font-family=\"sans-serif\" font-weight=\"700\">15 mm<\/text>\n      <!-- Cuvette bottom label -->\n      <text x=\"350\" y=\"98\" text-anchor=\"middle\" font-size=\"11\" fill=\"#666\" font-family=\"sans-serif\">K\u00fcvette (10 mm Schichtdicke)<\/text>\n      <!-- Beam label right -->\n      <text x=\"560\" y=\"128\" font-size=\"12\" fill=\"#c0730a\" font-family=\"sans-serif\" font-weight=\"600\">Transmittiert<\/text>\n    <\/svg>\n    <figcaption>Das Z-Ma\u00df ist der vertikale Abstand von der Ger\u00e4te-Grundplatte bis zum Zentrum des Lichtstrahls. Das optische Fenster der K\u00fcvette muss auf dieser H\u00f6he zentriert sein.<\/figcaption>\n  <\/div>\n\n  <!-- Key facts GEO block -->\n  <div class=\"zd-facts\">\n    <h3>Kernfakten<\/h3>\n    <ul>\n      <li>ISO-Standard-Z-Ma\u00df f\u00fcr K\u00fcvetten: <strong>15 mm<\/strong> (ISO 15189, ASTM E275)<\/li>\n      <li>G\u00e4ngige 8,5-mm-(Niedrig-Z-)Ger\u00e4te: <strong>8,5 mm<\/strong> : erfordert dedizierte Sub-Mikro- oder Mikrok\u00fcvetten<\/li>\n      <li>Das Z-Ma\u00df ist durch die Ger\u00e4tekonstruktion festgelegt; es l\u00e4sst sich ohne Distanzadapter nicht verstellen<\/li>\n      <li>Fluoreszenzk\u00fcvetten erfordern Z-Ma\u00df-Anpassung auf der Anregungs- und der Emissionsachse<\/li>\n      <li>Eine Fehlanpassung von nur 3\u20134 mm l\u00e4sst den Strahl das Fenster verfehlen und ergibt eine flache Basislinie<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<!-- SECTION 2: 15mm vs 8.5mm comparison -->\n<div style=\"margin-bottom:40px\">\n  <p class=\"zd-label\">Z-Ma\u00df-Standards<\/p>\n  <h2 style=\"font-size:24px;font-weight:700;color:#1a1a2e;margin:0 0 20px\">Die zwei Standard-Z-H\u00f6hen: 15 mm und 8,5 mm<\/h2>\n  <div class=\"zd-compare\">\n    <div class=\"zd-card\">\n      <span class=\"zd-badge\">Industriestandard<\/span>\n      <div class=\"zd-card-z\">15 mm<\/div>\n      <h3>Z = 15 mm<\/h3>\n      <p>Verwendet von der \u00fcberwiegenden Mehrheit der UV-Vis- und Fluoreszenz-Spektrophotometer, darunter PerkinElmer Lambda, Shimadzu, Agilent, Jasco und Thermo. Die meisten Ger\u00e4te nutzen Z = 15 mm; best\u00e4tigen Sie Ihres im Nachschlag-Tool unten.<\/p>\n<p style=\"background:#f0f4fc; border-left:3px solid #233a95; padding:10px 14px; border-radius:4px; font-size:14px;\">\ud83d\udcd8 <strong>Brauchen Sie mehr Tiefe?<\/strong> Lesen Sie den vollst\u00e4ndigen <a href=\"https:\/\/machinedquartz.com\/de\/fluoreszenzkuevetten-leitfaden\/\">Fluoreszenzk\u00fcvetten-Leitfaden<\/a> f\u00fcr 4-seitige Politur, Autofluoreszenz und 90\u00b0-Detektionsgeometrie; deckt alle Materialien, Volumina und Fluorometer-Kompatibilit\u00e4t ab.<\/p>\n\n      <ul>\n        <li>Agilent Cary 60, 100, 300, 4000, 5000, 6000i, Eclipse<\/li>\n        <li>Shimadzu UV-1280, UV-1800, UV-1900, UV-2600, UV-3600 series<\/li>\n        <li>Thermo Scientific Evolution and GENESYS series<\/li>\n        <li>Jasco V-series, FP-series<\/li>\n        <li>Hitachi U-series, F-series<\/li>\n        <li>Mettler-Toledo UV5, UV7<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"zd-card warn\">\n      <span class=\"zd-badge\">8,5-mm-Niedrig-Z-Ger\u00e4te<\/span>\n      <div class=\"zd-card-z\">8,5 mm<\/div>\n      <h3>Z = 8,5 mm<\/h3>\n      <p>Zu finden bei der Beckman-DU-Serie, Eppendorf BioPhotometer\/BioSpectrometer und diversen klinischen und \u00e4lteren Analyseger\u00e4ten. Diese erfordern K\u00fcvetten, die speziell mit Z = 8,5 mm spezifiziert sind; Standardk\u00fcvetten funktionieren ohne Adapter nicht.<\/p>\n      <ul>\n        <li>Erfordert Sub-Mikro-K\u00fcvetten mit Z = 8,5 mm Spezifikation<\/li>\n        <li>Standard-10-mm-K\u00fcvetten (Z=15) sitzen zu hoch im Halter<\/li>\n        <li>Distanzadapter verf\u00fcgbar, um Z=15-K\u00fcvetten als Behelf zu nutzen<\/li>\n        <li>Volumenbereich: typisch 50\u2013350 \u00b5L in Z=8,5-Mikroformaten<\/li>\n      <\/ul>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- SECTION 3: WHY IT MATTERS -->\n<div style=\"margin-bottom:40px\">\n  <p class=\"zd-label\">Warum es wichtig ist<\/p>\n  <h2 style=\"font-size:24px;font-weight:700;color:#1a1a2e;margin:0 0 16px\">Was passiert, wenn das Z-Ma\u00df falsch ist?<\/h2>\n  <div class=\"zd-warn-box\">\n    <strong>Eine Z-Ma\u00df-Fehlanpassung ist eine der h\u00e4ufigsten und zugleich am wenigsten offensichtlichen Ursachen f\u00fcr Messfehler in der UV-Vis-Spektroskopie.<\/strong> Anders als eine gerissene K\u00fcvette oder eine kontaminierte Zelle erzeugt eine Z-Fehlanpassung keinen sichtbaren Schaden. Das Ger\u00e4t schaltet normal ein, die Software l\u00e4dt, aber die Absorptionsmesswerte sind null, v\u00f6llig erratisch oder durchweg au\u00dferhalb des Bereichs, ohne Fehlermeldung, die erkl\u00e4rt, warum.\n  <\/div>\n  <p style=\"font-size:15px;line-height:1.8;color:#333;margin-bottom:16px\">Konkret: Wenn Sie eine Z=15 mm K\u00fcvette in ein Z=8,5 mm Ger\u00e4t (wie einen Beckman DU 800) ohne Adapter setzen:<\/p>\n  <ul style=\"font-size:15px;line-height:2;color:#333;padding-left:22px;margin-bottom:16px\">\n    <li>Der Strahl l\u00e4uft durch die <strong>obere Wand der K\u00fcvette<\/strong>, nicht durch die Probe<\/li>\n    <li>Die Absorption liest nahe null, unabh\u00e4ngig von der Probenkonzentration<\/li>\n    <li>Streulicht steigt und beeintr\u00e4chtigt die Beer-Lambert-Linearit\u00e4t<\/li>\n    <li>Die K\u00fcvette sitzt m\u00f6glicherweise nicht korrekt, was Reproduzierbarkeitsprobleme zwischen Messungen verursacht<\/li>\n  <\/ul>\n  <p style=\"font-size:15px;line-height:1.8;color:#333\">Umgekehrt l\u00e4sst das Setzen einer Z=8,5 mm K\u00fcvette in ein Z=15 mm Ger\u00e4t den Strahl durch den <strong>unteren Teil der K\u00fcvette<\/strong> laufen, oft ganz unterhalb des optischen Fensters, und erzeugt kein Signal.<\/p>\n<\/div>\n\n<!-- SECTION 4: LOOKUP TOOL -->\n<div style=\"margin-bottom:40px\">\n  <p class=\"zd-label\">Ger\u00e4te-Datenbank<\/p>\n  <h2 style=\"font-size:24px;font-weight:700;color:#1a1a2e;margin:0 0 6px\">Z-Ma\u00df-Nachschlag-Tool<\/h2>\n  <p style=\"font-size:14px;color:#666;margin:0 0 18px\">Durchsuchen Sie 154+ Spektrophotometer-Modelle, um sofort das korrekte K\u00fcvetten-Z-Ma\u00df zu best\u00e4tigen.<\/p>\n\n  <div class=\"zp-tool\">\n    <div class=\"zp-row\">\n      <div class=\"zp-field\">\n        <label for=\"zp-brand\">Marke<\/label>\n        <select id=\"zp-brand\" onchange=\"zpBrand()\">\n          <option value=\"\">Alle Marken<\/option>\n        <\/select>\n      <\/div>\n      <div class=\"zp-field\">\n        <label for=\"zp-model\">Modellname oder -nummer<\/label>\n        <input type=\"text\" id=\"zp-model\" placeholder=\"e.g. Lambda 650, UV-1800\" oninput=\"zpHint()\" onkeydown=\"if(event.key==='Enter')zpLookup()\">\n      <\/div>\n      <button class=\"zp-btn\" onclick=\"zpLookup()\">Nachschlagen<\/button>\n    <\/div>\n    <div class=\"zp-hint\" id=\"zp-hint\"><\/div>\n    <div class=\"zp-res\" id=\"zp-res\">\n      <div class=\"res-hd\">\n        <div class=\"res-badge\" id=\"zp-badge\"><\/div>\n        <div><div class=\"res-name\" id=\"zp-name\"><\/div><div class=\"res-sub\" id=\"zp-sub\"><\/div><\/div>\n      <\/div>\n      <div class=\"cc-grid\" id=\"zp-cg\"><\/div>\n      <div class=\"zp-tip\" id=\"zp-tip\"><\/div>\n    <\/div>\n    <div class=\"zp-nores\" id=\"zp-nores\">Keine Ergebnisse gefunden.<\/div>\n  <\/div>\n\n  <div style=\"background:#f7f8fc;border:1px solid #e0e4f0;border-radius:8px;padding:12px 18px;margin-bottom:14px;font-size:12px;color:#666;line-height:1.6\">\n  <strong style=\"color:#1a1a2e\">Datenquellen & Haftungsausschluss:<\/strong> Z-Ma\u00df-Werte sind referenziert von <a href=\"https:\/\/cuvet.co\/z-dimensions\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#233a95\">cuvet.co<\/a> und gegen Herstellerspezifikationen und Ger\u00e4tehandb\u00fccher gegengepr\u00fcft. Die 8,5-mm-Niedrig-Z-Gruppe (Beckman DU, Eppendorf und klinische Analyseger\u00e4te) und die 15-mm-Standardgruppe (PerkinElmer Lambda, Agilent, Shimadzu, Jasco, Thermo und die meisten Hitachi) spiegeln ver\u00f6ffentlichte Ger\u00e4tespezifikationen und unsere cuvet.co-Ger\u00e4tedatenbank wider. <strong>Verifizieren Sie immer mit Ihrem Ger\u00e4tehandbuch vor der Bestellung; Spezifikationen k\u00f6nnen je nach Ger\u00e4tekonfiguration, Zubeh\u00f6rhalter oder Modelljahr variieren.<\/strong>\n<\/div>\n<p style=\"font-size:13px;font-weight:700;color:#1a1a2e;margin:0 0 10px\">Alle durchsuchen <span id=\"zp-count\">(55 Ger\u00e4te)<\/span>:<\/p>\n  <div class=\"fb\">\n    <button class=\"fb-btn active\" onclick=\"zpFilter(this,'all')\">Alle<\/button>\n    <button class=\"fb-btn\" onclick=\"zpFilter(this,'UV-Vis')\">UV-Vis (UV\/Sichtbar)<\/button>\n    <button class=\"fb-btn\" onclick=\"zpFilter(this,'UV-Vis-NIR')\">UV-Vis-NIR<\/button>\n    <button class=\"fb-btn\" onclick=\"zpFilter(this,'Fluorescence')\">Fluoreszenz<\/button>\n    <button class=\"fb-btn\" onclick=\"zpFilter(this,'z15')\">Z = 15 mm<\/button>\n    <button class=\"fb-btn\" onclick=\"zpFilter(this,'z85')\">Z = 8,5 mm<\/button>\n    <button class=\"fb-btn\" onclick=\"zpFilter(this,'z20')\">Z = 20 mm<\/button>\n  <\/div>\n  <div class=\"zt-wrap\">\n    <table class=\"zt\">\n      <thead><tr><th>Marke<\/th><th>Modell<\/th><th>Typ<\/th><th>Z-Ma\u00df<\/th><th>Kompatible K\u00fcvetten<\/th><\/tr><\/thead>\n      <tbody id=\"zp-tb\"><\/tbody>\n    <\/table>\n  <\/div>\n  <div id=\"zp-toggle\" style=\"display:none;text-align:center;margin:8px 0 4px\">\u00a0<\/div>\n  <div class=\"zp-nores\" id=\"zp-nores\" style=\"display:none\">Keine Ger\u00e4te entsprechen diesem Filter.<\/div>\n<\/div>\n\n<!-- SECTION 5: HOW TO IDENTIFY Z DIMENSION -->\n<div style=\"margin-bottom:40px\">\n  <p class=\"zd-label\">Identifizierungsleitfaden<\/p>\n  <h2 style=\"font-size:24px;font-weight:700;color:#1a1a2e;margin:0 0 20px\">Wie Sie das Z-Ma\u00df Ihres Ger\u00e4ts identifizieren<\/h2>\n  <div class=\"zd-steps\">\n    <div class=\"zd-step\">\n      <div class=\"zd-step-num\">01<\/div>\n      <h3>Das Ger\u00e4tehandbuch pr\u00fcfen<\/h3>\n      <p>Die meisten Ger\u00e4tehandb\u00fccher listen das Z-Ma\u00df (manchmal als \u201eStrahlh\u00f6he\u201c oder \u201eAperturh\u00f6he\u201c bezeichnet) im Abschnitt K\u00fcvettenspezifikationen. Suchen Sie einen Wert zwischen 8 und 20 mm.<\/p>\n    <\/div>\n    <div class=\"zd-step\">\n      <div class=\"zd-step-num\">02<\/div>\n      <h3>Die Nachschlagetabelle oben nutzen<\/h3>\n      <p>Suchen Sie Ihre Ger\u00e4temarke und Modellnummer in unserer Datenbank mit 55+ Spektrophotometern. Die h\u00e4ufigsten Werte sind 15 mm (die meisten Marken) und 8,5 mm (Beckman DU, Eppendorf und diverse klinische Ger\u00e4te).<\/p>\n    <\/div>\n    <div class=\"zd-step\">\n      <div class=\"zd-step-num\">03<\/div>\n      <h3>Direkt messen<\/h3>\n      <p>Legen Sie ein Lineal in den leeren K\u00fcvettenhalter und messen Sie von der Grundplatte bis zum Zentrum der Apertur\u00f6ffnung. Verifizieren Sie mit einer bekannt guten K\u00fcvette: der Strahl sollte sauber durch das Zentrum des optischen Fensters laufen.<\/p>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- SECTION 6: CUVETTE TYPES BY Z VALUE -->\n<div style=\"margin-bottom:40px\">\n  <p class=\"zd-label\">K\u00fcvettenauswahl<\/p>\n  <h2 style=\"font-size:24px;font-weight:700;color:#1a1a2e;margin:0 0 16px\">K\u00fcvettentypen nach Z-Ma\u00df<\/h2>\n  <p style=\"font-size:15px;line-height:1.8;color:#333;margin-bottom:20px\">Verschiedene K\u00fcvettenformate werden f\u00fcr bestimmte Z-Werte gefertigt. Die Tabelle unten zeigt, welche K\u00fcvettentypen in jeder Z-Konfiguration verf\u00fcgbar sind, und ihre typischen Volumenbereiche.<\/p>\n  <div style=\"overflow-x:auto\">\n    <table class=\"zd-type-table\">\n      <thead>\n        <tr>\n          <th>K\u00fcvettentyp<\/th>\n          <th>Z-Ma\u00df<\/th>\n          <th>Volumenbereich<\/th>\n          <th>Schichtdicken-Optionen<\/th>\n          <th>Hinweise<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td><strong>Standardk\u00fcvette<\/strong><\/td>\n          <td><span class=\"zd-zbadge z15\">Z = 15 mm<\/span><\/td>\n          <td>1,4\u20134,5 mL<\/td>\n          <td>1, 2, 5, 10, 20, 50, 100 mm<\/td>\n          <td>ISO-Standardma\u00dfe; funktioniert in allen Z=15-Ger\u00e4ten<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>Halbmikrok\u00fcvette<\/strong><\/td>\n          <td><span class=\"zd-zbadge z15\">Z = 15 mm<\/span><\/td>\n          <td>0,35\u20131,4 mL<\/td>\n          <td>10 mm Standard<\/td>\n          <td>Schmalerer K\u00f6rper zur Reduzierung des Probenvolumens; gleiches Z wie Standard<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>Mikrok\u00fcvette<\/strong><\/td>\n          <td><span class=\"zd-zbadge z15\">Z = 15 mm<\/span><\/td>\n          <td>70\u2013400 \u00b5L<\/td>\n          <td>10 mm Standard<\/td>\n          <td>Kleines Aperturfenster zur Reduzierung des Wegs durch Luft; erfordert sorgf\u00e4ltige Ausrichtung<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>Sub-Mikro-K\u00fcvette<\/strong><\/td>\n          <td><span class=\"zd-zbadge z85\">Z = 8,5 mm<\/span><\/td>\n          <td>50\u2013150 \u00b5L<\/td>\n          <td>10 mm Standard<\/td>\n          <td>F\u00fcr 8,5-mm-Niedrig-Z-Ger\u00e4te (Beckman DU, Eppendorf) konzipiert; ohne Adapter nicht in Z=15-Ger\u00e4ten substituierbar<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>Mikrok\u00fcvette (Z=8,5)<\/strong><\/td>\n          <td><span class=\"zd-zbadge z85\">Z = 8,5 mm<\/span><\/td>\n          <td>100\u2013350 \u00b5L<\/td>\n          <td>10 mm Standard<\/td>\n          <td>Volumenst\u00e4rkere Alternative zur Sub-Mikro f\u00fcr Z=8,5-Ger\u00e4te<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>Durchflussk\u00fcvette<\/strong><\/td>\n          <td><span class=\"zd-zbadge z15\">Z = 15 mm<\/span><\/td>\n          <td>Kontinuierlicher Durchfluss<\/td>\n          <td>1\u201310 mm<\/td>\n          <td>Z=15 Standard; Sonder-Z-H\u00f6hen auf Anfrage verf\u00fcgbar<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>Langweg-K\u00fcvette<\/strong><\/td>\n          <td><span class=\"zd-zbadge z15\">Z = 15 mm<\/span><\/td>\n          <td>1\u20134 mL<\/td>\n          <td>20, 50, 100 mm<\/td>\n          <td>Verl\u00e4ngerte Schichtdicke f\u00fcr verd\u00fcnnte Proben; nur Z=15<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>Fluoreszenzk\u00fcvette<\/strong><\/td>\n          <td><span class=\"zd-zbadge both\">Z = 15 mm (Sonder)<\/span><\/td>\n          <td>0,5\u20133,5 mL<\/td>\n          <td>10 mm (4-Fenster)<\/td>\n          <td>Vier polierte Fenster; Z muss zu Anregungs- und Emissions-Strahlh\u00f6he passen<\/td>\n        <\/tr>\n        <tr>\n          <td><strong>Sondergeometrie<\/strong><\/td>\n          <td><span class=\"zd-zbadge both\">Beliebiges Z auf Anfrage<\/span><\/td>\n          <td>Sonder<\/td>\n          <td>Beliebige Schichtdicke<\/td>\n          <td><a href=\"https:\/\/machinedquartz.com\/de\/quarz-sonderkuevetten\/\" style=\"color:#233a95;font-weight:600\">Quarz-Sonderk\u00fcvetten<\/a> k\u00f6nnen f\u00fcr nicht standardm\u00e4\u00dfige optische B\u00e4nke auf jedes Z-Ma\u00df gefertigt werden<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/div>\n\n<!-- SECTION 7: USING ADAPTERS -->\n<div style=\"margin-bottom:40px\">\n  <p class=\"zd-label\">Behelfsl\u00f6sungen<\/p>\n  <h2 style=\"font-size:24px;font-weight:700;color:#1a1a2e;margin:0 0 16px\">Distanzadapter zur \u00dcberbr\u00fcckung von Z-Ma\u00dfen verwenden<\/h2>\n  <p style=\"font-size:15px;line-height:1.8;color:#333;margin-bottom:16px\">Wenn Sie eine Z=15 mm K\u00fcvette in einem Z=8,5 mm Ger\u00e4t verwenden m\u00fcssen (oder umgekehrt), hebt oder senkt ein <strong>Distanzadapter<\/strong> (auch Z-Adapter oder K\u00fcvettenhalter-Einsatz genannt) die K\u00fcvette, um das optische Fenster mit dem Strahlzentrum auszurichten.<\/p>\n  <p style=\"font-size:15px;line-height:1.8;color:#333;margin-bottom:16px\">Drittanbieter bieten 6,5-mm-Distanzst\u00fccke f\u00fcr 8,5-mm-Niedrig-Z-Halter an. Ein Adapter erlaubt Standard-10-mm-K\u00fcvetten (Z=15), in 8,5-mm-Ger\u00e4ten zu funktionieren, allerdings mit einigen Kompromissen:<\/p>\n  <ul style=\"font-size:15px;line-height:2;color:#333;padding-left:22px;margin-bottom:16px\">\n    <li>Die Mindestvolumenanforderung steigt (der Adapter hebt die K\u00fcvette, sodass mehr Probe n\u00f6tig ist, um die Strahlh\u00f6he zu erreichen)<\/li>\n    <li>Etwas Basislinienrauschen kann durch unvollkommene Adapterausrichtung entstehen<\/li>\n    <li>Nicht f\u00fcr sehr kleine Volumina geeignet: Sub-Mikro-Messungen erfordern weiterhin dedizierte Z=8,5-K\u00fcvetten<\/li>\n  <\/ul>\n  <p style=\"font-size:15px;line-height:1.8;color:#333\">F\u00fcr Anwendungen, bei denen das Probenvolumen kritisch ist, empfehlen wir, K\u00fcvetten zu bestellen, die speziell f\u00fcr das Z-Ma\u00df Ihres Ger\u00e4ts gefertigt sind. <a href=\"https:\/\/machinedquartz.com\/de\/quarz-sonderkuevetten\/\" style=\"color:#233a95;font-weight:600\">MachinedQuartz kann Quarzk\u00fcvetten auf jedes Z-Ma\u00df fertigen<\/a> mit Toleranzen von \u00b10,1 mm auf der Z-H\u00f6he.<\/p>\n<\/div>\n\n<!-- SECTION 8: FAQ -->\n<div style=\"margin-bottom:40px\">\n  <p class=\"zd-label\">FAQ<\/p>\n  <h2 style=\"font-size:24px;font-weight:700;color:#1a1a2e;margin:0 0 20px\">H\u00e4ufig gestellte Fragen<\/h2>\n  <div id=\"zd-faq\">\n    <div class=\"zd-faq-item\">\n      <div class=\"zd-faq-q\">Was ist das Standard-Z-Ma\u00df f\u00fcr UV-Vis-K\u00fcvetten?<span class=\"zd-faq-icon\">+<\/span><\/div>\n      <div class=\"zd-faq-a\"><p>Das ISO-Standard-Z-Ma\u00df f\u00fcr UV-Vis-Spektrophotometer-K\u00fcvetten ist 15 mm. Es wird von Agilent (Cary), Shimadzu, Thermo Scientific, Jasco, Hitachi, Mettler-Toledo und den meisten anderen Ger\u00e4temarken verwendet. Die 8,5-mm-Niedrig-Z-Ausnahme findet sich bei der Beckman-DU-Serie, Eppendorf-Photometern und diversen klinischen und \u00e4lteren Analyseger\u00e4ten.<\/p><\/div>\n    <\/div>\n    <div class=\"zd-faq-item\">\n      <div class=\"zd-faq-q\">Woher wei\u00df ich, ob mein Ger\u00e4t Z = 8,5 mm K\u00fcvetten braucht?<span class=\"zd-faq-icon\">+<\/span><\/div>\n      <div class=\"zd-faq-a\"><p>Wenn Ihr Ger\u00e4t eine Beckman-DU-Serie, ein Eppendorf BioPhotometer\/BioSpectrometer oder eines von diversen klinischen Analyseger\u00e4ten ist, erfordert es wahrscheinlich Z = 8,5 mm K\u00fcvetten. PerkinElmer Lambda, Shimadzu, Agilent, Jasco und Thermo nutzen Z = 15 mm. Im Zweifel das Nachschlag-Tool oben verwenden oder Ihr Ger\u00e4tehandbuch unter \u201eK\u00fcvettenspezifikationen\u201c konsultieren.<\/p><\/div>\n    <\/div>\n    <div class=\"zd-faq-item\">\n      <div class=\"zd-faq-q\">Kann ich eine Standard-10-mm-K\u00fcvette in einem Beckman DU 800 verwenden?<span class=\"zd-faq-icon\">+<\/span><\/div>\n      <div class=\"zd-faq-a\"><p>Nicht direkt. Eine Standard-K\u00fcvette mit 10 mm Schichtdicke hat Z = 15 mm. Der DU 800 nutzt Z = 8,5 mm, sodass der Strahl oberhalb des optischen Fensters einer Standardk\u00fcvette auftrifft und kein Signal erzeugt. Sie haben zwei Optionen: (1) eine dedizierte Sub-Mikro- oder Mikrok\u00fcvette mit Z = 8,5 mm verwenden oder (2) einen Distanzadapter kaufen, der eine Z=15-K\u00fcvette um 6,5 mm absenkt, um sie mit dem Strahl auszurichten. Option 1 ist f\u00fcr die Kleinvolumengenauigkeit zu bevorzugen.<\/p><\/div>\n    <\/div>\n    <div class=\"zd-faq-item\">\n      <div class=\"zd-faq-q\">Was ist der Unterschied zwischen Z-Ma\u00df und Schichtdicke?<span class=\"zd-faq-icon\">+<\/span><\/div>\n      <div class=\"zd-faq-a\"><p>Die Schichtdicke ist der horizontale Weg, den der Lichtstrahl durch die Probe in der K\u00fcvette zur\u00fccklegt, typisch 10 mm f\u00fcr Standardk\u00fcvetten. Das Z-Ma\u00df ist die vertikale H\u00f6he des Strahls \u00fcber der Ger\u00e4te-Grundplatte. Es sind unabh\u00e4ngige Spezifikationen. Eine K\u00fcvette mit 10 mm Schichtdicke kann in beiden Ausf\u00fchrungen Z=15 mm und Z=8,5 mm existieren. Die Schichtdicke bestimmt die Beer-Lambert-Konzentrationsberechnung; das Z-Ma\u00df bestimmt die physische Ger\u00e4tekompatibilit\u00e4t.<\/p><\/div>\n    <\/div>\n    <div class=\"zd-faq-item\">\n      <div class=\"zd-faq-q\">Kann MachinedQuartz K\u00fcvetten mit einem Sonder-Z-Ma\u00df fertigen?<span class=\"zd-faq-icon\">+<\/span><\/div>\n      <div class=\"zd-faq-a\"><p>Ja. MachinedQuartz ist spezialisiert auf <a href=\"https:\/\/machinedquartz.com\/de\/quarz-sonderkuevetten\/\" style=\"color:#233a95;font-weight:600\">Quarz-Sonderk\u00fcvetten<\/a> und kann K\u00fcvetten auf jedes spezifizierte Z-Ma\u00df fertigen. Das ist n\u00fctzlich f\u00fcr nicht standardm\u00e4\u00dfige optische B\u00e4nke, OEM-Ger\u00e4teintegrationen, Faseroptiksonden und kundenspezifische Photoreaktor-Aufbauten. Die Z-H\u00f6hen-Toleranz betr\u00e4gt \u00b10,1 mm. Die Lieferzeit f\u00fcr Sonder-Z-Ma\u00dfe betr\u00e4gt typischerweise 5\u20138 Werktage f\u00fcr Sinter- und Standardqualit\u00e4ten, etwa 30 Tage f\u00fcr Molded- (integral verschmolzene) Designs. Kontaktieren Sie uns mit Ihrem Ger\u00e4temodell, der ben\u00f6tigten Z-H\u00f6he, Schichtdicke und Volumenanforderung.<\/p><\/div>\n    <\/div>\n    <div class=\"zd-faq-item\">\n      <div class=\"zd-faq-q\">Spielt das Z-Ma\u00df f\u00fcr Fluoreszenzk\u00fcvetten eine Rolle?<span class=\"zd-faq-icon\">+<\/span><\/div>\n      <div class=\"zd-faq-a\"><p>Ja, und es ist komplexer f\u00fcr Fluoreszenzger\u00e4te. Ein Fluoreszenz-Spektrophotometer hat zwei Strahleng\u00e4nge: den Anregungsstrahl (tritt vorne in die K\u00fcvette ein) und den Emissionsstrahl (tritt im 90\u00b0-Winkel aus). Beide Wege haben ein Z-Ma\u00df, das zur Fensterposition der K\u00fcvette passen muss. Die meisten Fluoreszenzger\u00e4te nutzen Z = 15 mm f\u00fcr beide Achsen. Vier-Fenster-Fluoreszenzk\u00fcvetten, die f\u00fcr Z=15-Ger\u00e4te gefertigt sind, funktionieren nicht in Ger\u00e4ten mit anderen Z-Spezifikationen, es sei denn, die K\u00fcvette ist ma\u00dfgefertigt, um beiden Strahlh\u00f6hen zu entsprechen.<\/p><\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<!-- CTA -->\n<div class=\"zd-cta\">\n  <h2>Brauchen Sie K\u00fcvetten f\u00fcr ein bestimmtes Z-Ma\u00df?<\/h2>\n  <p>MachinedQuartz fertigt Quarz-Sonderk\u00fcvetten auf jede Z-H\u00f6he, Schichtdicke und Volumenspezifikation, mit 5\u20138 Tagen Lieferzeit und ohne Mindestbestellmenge.<\/p>\n  <div class=\"zd-cta-btns\">\n    <a href=\"https:\/\/machinedquartz.com\/de\/quarz-sonderkuevetten\/\" class=\"zd-cta-btn primary\">Sonderk\u00fcvetten ansehen<\/a>\n    <a href=\"https:\/\/machinedquartz.com\/contact\/\" class=\"zd-cta-btn secondary\">Angebot anfordern<\/a>\n  <\/div>\n<\/div>\n\n<!-- Internal links block -->\n<div style=\"background:#f7f8fc;border-radius:10px;padding:20px 24px;margin-bottom:32px;font-size:14px;line-height:1.8\">\n  <strong style=\"display:block;margin-bottom:8px;color:#1a1a2e\">Verwandte Ressourcen:<\/strong>\n  <a href=\"https:\/\/machinedquartz.com\/de\/quarz-sonderkuevetten\/\" style=\"color:#233a95;font-weight:600;display:block\">Quarz-Sonderk\u00fcvetten: beliebige Schichtdicke, beliebiges Z-Ma\u00df, Versand in 5\u20138 Tagen<\/a>\n  <a href=\"https:\/\/machinedquartz.com\/de\/herstellungsverfahren-quarzkuevetten\/\" style=\"color:#233a95;font-weight:600;display:block\">K\u00fcvetten-Fertigungsmethoden: Standard 80, Sintered und Molded erkl\u00e4rt<\/a>\n  <a href=\"https:\/\/machinedquartz.com\/comparative-analysis-of-quartz-cuvette-models-for-scientific-oem-use\/\" style=\"color:#233a95;font-weight:600;display:block\">Vergleichsanalyse von Quarzk\u00fcvetten-Modellen f\u00fcr OEM-Einsatz<\/a>\n  <a href=\"https:\/\/machinedquartz.com\/cuvettes-and-cells-size-chart\/\" style=\"color:#233a95;font-weight:600;display:block\">K\u00fcvetten-Gr\u00f6\u00dfentabelle: Standard-Au\u00dfenma\u00dfe und Volumenreferenz<\/a>\n<\/div>\n\n<p style=\"font-size:12px;color:#aaa;text-align:right;margin-top:8px\">Seite zuletzt gepr\u00fcft: April 2026 | MachinedQuartz Technical Documentation<\/p>\n\n<\/div>\n\n\n\n<script>\nvar DB=[\n[\"ABX\",\"Cobas Argos 5 Diff\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"ABX\",\"Cobas Helios 5 Diff\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"ABX\",\"Cobas Minos Range\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Agilent\",\"8450\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Agilent\",\"8451\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Agilent\",\"8452 UV\/Vis\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Agilent\",\"8453 A\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Agilent\",\"Cary 1\",20,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 100\",20,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 118\",15,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 14\",12.5,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 16\",13.0,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 165\",15,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 18\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Agilent\",\"Cary 210\",15,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 3\",20,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 300\",20,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 4\",20,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 400\",20,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 4000\",20,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 5\",20,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 50\",20,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 500\",20,\"UV-Vis-NIR\",\"\"],\n[\"Agilent\",\"Cary 5000\",20,\"UV-Vis-NIR\",\"\"],\n[\"Agilent\",\"Cary 60\",15,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary 6000i\",20,\"UV-Vis-NIR\",\"\"],\n[\"Agilent\",\"Cary 8454\",15,\"UV-Vis\",\"\"],\n[\"Agilent\",\"Cary Eclipse\",20,\"Fluorescence\",\"\"],\n[\"Agilent\",\"Eclipse\",20.0,\"Fluorescence\",\"Standard, Halbmikro, Mikro (Z=20), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"500\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Biochrm 4060\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"GeneQuant 100\",15,\"UV-Vis\",\"\"],\n[\"Amersham Biosciences\",\"GeneQuant 1300\",15,\"UV-Vis\",\"\"],\n[\"Amersham Biosciences\",\"GeneQuant Pro\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"NanoView\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Novospec\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Novospec II\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Novospec III\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Novospec Plus\",15,\"UV-Vis\",\"\"],\n[\"Amersham Biosciences\",\"Ultospec 1000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec 1100\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec 2000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec 2100\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec 2100 Pro\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec 3000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec 3100\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec 3300\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec 4000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec 4300\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec 5300\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec 6300\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultospec Plus\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultrospec 10\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Amersham Biosciences\",\"Ultrospec 2100 Pro\",15,\"UV-Vis\",\"\"],\n[\"Amersham Biosciences\",\"Ultrospec 3000\",15,\"UV-Vis\",\"\"],\n[\"Amersham Biosciences\",\"Ultrospec 3300\",15,\"UV-Vis\",\"\"],\n[\"Aminco\",\"Bowman\",9.0,\"UV-Vis\",\"\"],\n[\"Aminco\",\"Bowman Model 4-8202\",12.0,\"UV-Vis\",\"Standard, Halbmikro (Z=12), Langweg-K\u00fcvetten\"],\n[\"Aminco\",\"SPF-125\",15.0,\"Fluorescence\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Analytik Jena\",\"SPECORD 200\",15,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"SPECORD 200 PLUS\",15,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"SPECORD 205\",15,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"Specord 205\/210\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Analytik Jena\",\"SPECORD 210\",15,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"SPECORD 210 PLUS\",15,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"SPECORD 250\",15,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"SPECORD 30\",8.5,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"SPECORD 40\",8.5,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"SPECORD 50\",8.5,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"SPECORD 50 PLUS\",15,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"SPECORD S 100\",15,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"Spekol 1100\",8.5,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"Spekol 1200\",15,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"Spekol 1500\",15,\"UV-Vis\",\"\"],\n[\"Analytik Jena\",\"Spekol 2000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Baird\",\"Atomic PN 8830\",12.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"DU 40\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Beckman Coulter\",\"DU 50\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Beckman Coulter\",\"DU 500\",8.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"DU 520\",8.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"DU 530\",8.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"DU 60\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Beckman Coulter\",\"DU 600\",8.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"DU 640\",8.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"DU 650\",8.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"DU 7\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Beckman Coulter\",\"DU 70\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Beckman Coulter\",\"DU 7000\",8.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"DU 730\",10,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"DU 7400\",8.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"DU 7500\",8.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"DU 800\",8.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"Kintrac VII\",17.0,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"Modell 24\/25\/26\",8.4,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"Modell 5260\",17.0,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"SF 1078\",18.5,\"UV-Vis\",\"\"],\n[\"Beckman Coulter\",\"USA Acta Autosampler\",11.68,\"UV-Vis\",\"\"],\n[\"Bio-Rad\",\"SmartSpec 3000\",8.5,\"UV-Vis\",\"\"],\n[\"Bio-Rad\",\"SmartSpec Plus\",8.5,\"UV-Vis\",\"\"],\n[\"Bio-System\",\"BTS 302\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Bio-System\",\"BTS 305\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Bio-System\",\"BTS 310\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Bio-System\",\"BTS 320\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"Libra S11\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"Libra S12\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"Libra S21\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"Libra S22\",15,\"UV-Vis\",\"\"],\n[\"Biochrom\",\"Libra S32\",15,\"UV-Vis\",\"\"],\n[\"Biochrom\",\"Libra S32PC\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"Libra S4\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"Libra S50\",15,\"UV-Vis\",\"\"],\n[\"Biochrom\",\"Libra S50PC\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"Libra S60\",15,\"UV-Vis\",\"\"],\n[\"Biochrom\",\"Libra S60PC\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"Libra S70\",15,\"UV-Vis\",\"\"],\n[\"Biochrom\",\"Libra S70PC\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"Libra S80\",15,\"UV-Vis\",\"\"],\n[\"Biochrom\",\"Libra S80PC\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"WPA Biowave DNA\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"WPA Biowave II\",15,\"UV-Vis\",\"\"],\n[\"Biochrom\",\"WPA Lightwave II\",15,\"UV-Vis\",\"\"],\n[\"Biochrom\",\"WPA S1200\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Biochrom\",\"WPA S800\",15,\"UV-Vis\",\"\"],\n[\"Biorad\",\"SmartSpec TM 3000\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Biotecnica\",\"Arco\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Biotecnica\",\"BT 224\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Biotecnica\",\"BT 2245\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Biotecnica\",\"BT 225\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"SFM 25\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"Uvikon 725\",12.0,\"UV-Vis\",\"Standard, Halbmikro (Z=12), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"Uvikon 810\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"Uvikon 922\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"Uvikon 923 B\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"Uvikon 930\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"Uvikon 940\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"Uvikon 941\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"Uvikon 942\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"Uvikon 943\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"Uvikon XL\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"Uvikon XS\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"BioTek\",\"UviLight\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Boeco\",\"S 20\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Boeco\",\"S 22\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Braic\",\"UV-1000\",17.0,\"UV-Vis\",\"\"],\n[\"Braic\",\"UV-9100\",23.5,\"UV-Vis\",\"\"],\n[\"Braic\",\"VIS-7220\",23.5,\"UV-Vis\",\"\"],\n[\"Bruins Instruments\",\"Omega 10\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Bruins Instruments\",\"Omega 20\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Bruins Instruments\",\"Omega 30\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Camspec\",\"M 201\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Camspec\",\"M 202\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Camspec\",\"M 230\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Camspec\",\"M 301\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Camspec\",\"M 302\",15,\"UV-Vis\",\"\"],\n[\"Camspec\",\"M 330\",15,\"UV-Vis\",\"\"],\n[\"Camspec\",\"M 350\",15,\"UV-Vis\",\"\"],\n[\"Camspec\",\"M 501\",15,\"UV-Vis\",\"\"],\n[\"Cecil\",\"CE 1010\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 1020\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 2010\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 2020\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 2030\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 2040\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 2202\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 2272\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 2293\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 2303\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 2393\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 404\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 500\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 5000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 505\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 5095 \/ 500\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 5095 \/ 560\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 545\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 594\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 595\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 599\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 6000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 7000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 8000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 8020\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Cecil\",\"CE 9000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"CGA\",\"EOS 880\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"CGA\",\"EOS 890\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Ciba Corning\",\"258\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Ciba Corning\",\"259\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Ciba Corning\",\"2800 SpectraScan\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Dr. Lange\",\"Cadas 100\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Dr. Lange\",\"Cadas 200\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Dr. Lange\",\"Cadas 30\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Dr. Lange\",\"Cadas 50\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Dr. Lange\",\"LP 1\",11.0,\"UV-Vis\",\"\"],\n[\"Dr. Lange\",\"LP 1 W\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Dr. Lange\",\"LP 2\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Dr. Lange\",\"LP 6 A\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Dr. Lange\",\"Mosy\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Dr. Lange\",\"Xion 500\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Drake\",\"Quick-Lab\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Elvi\",\"-398\",9.5,\"UV-Vis\",\"\"],\n[\"Eppendorf\",\"1101 M\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Eppendorf\",\"6114\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Eppendorf\",\"6118\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Eppendorf\",\"6120\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Eppendorf\",\"BioPhotometer\",8.5,\"UV-Vis\",\"\"],\n[\"Eppendorf\",\"BioPhotometer Plus\",8.5,\"UV-Vis\",\"\"],\n[\"Eppendorf\",\"BioSpectrometer\",8.5,\"UV-Vis\",\"\"],\n[\"Eppendorf\",\"BioSpectrometer Basic\",8.5,\"UV-Vis\",\"\"],\n[\"Eppendorf\",\"BioSpectrometer Fluorescence\",8.5,\"Fluorescence\",\"\"],\n[\"Eppendorf\",\"Ecom-F 6124\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Eppendorf\",\"Ecom-P 4153\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Eppendorf\",\"Epac 6140\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Femto\",\"600\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Femto\",\"600 Plus\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Femto\",\"600 S\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Femto\",\"700\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Femto\",\"700 Plus\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Femto\",\"700 S\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Femto\",\"800 XI\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"GBC\",\"920-UV\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"GBC\",\"Cintra 10\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"GBC\",\"Cintra 20\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"GBC\",\"Cintra 40\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"GBC\",\"Cintra 5\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Hach\",\"DR-2000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Hach\",\"DR-3000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Hach\",\"DR-4000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Hach\",\"DR-5000\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hewlett Packard\",\"all Types of Hewlett Packard\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"150-20\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"181\",14.5,\"UV-Vis\",\"\"],\n[\"Hitachi\",\"F-2000\",6.0,\"Fluorescence\",\"\"],\n[\"Hitachi\",\"F-2500\",6.0,\"Fluorescence\",\"\"],\n[\"Hitachi\",\"F-4500\",4.5,\"Fluorescence\",\"\"],\n[\"Hitachi\",\"F-4600\",4.5,\"Fluorescence\",\"\"],\n[\"Hitachi\",\"F-7000\",4.5,\"Fluorescence\",\"\"],\n[\"Hitachi\",\"F-7100\",4.5,\"Fluorescence\",\"\"],\n[\"Hitachi\",\"U-1000\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-1100\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-1500\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-1800\",12.5,\"UV-Vis\",\"\"],\n[\"Hitachi\",\"U-1900\",10,\"UV-Vis\",\"\"],\n[\"Hitachi\",\"U-2000\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-2001\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-2010\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-2800\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-2900\",10,\"UV-Vis\",\"\"],\n[\"Hitachi\",\"U-2910\",10,\"UV-Vis\",\"\"],\n[\"Hitachi\",\"U-3000\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-3010\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-3200\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-3300\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-3400\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-3501\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-3900\",10,\"UV-Vis-NIR\",\"\"],\n[\"Hitachi\",\"U-4001\",10.0,\"UV-Vis\",\"Standard, Halbmikro (Z=10), Langweg-K\u00fcvetten\"],\n[\"Hitachi\",\"U-4100\",10,\"UV-Vis-NIR\",\"\"],\n[\"Hitachi\",\"U-5100\",10,\"UV-Vis\",\"\"],\n[\"Hoefer\",\"Dyna Quant 200\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Horiba\",\"Duetta\",15,\"Fluorescence\",\"\"],\n[\"Horiba\",\"FluoroMax 4\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Horiba\",\"FluoroMax Plus\",15,\"Fluorescence\",\"\"],\n[\"Horiba\",\"FluoroMax-3\",15,\"Fluorescence\",\"\"],\n[\"Horiba\",\"FluoroMax-4\",15,\"Fluorescence\",\"\"],\n[\"ISA\",\"FluoroMax\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"FP 6200\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"FP 6300\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"FP 6500\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"FP 6600\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"FP-8300\",15,\"Fluorescence\",\"\"],\n[\"Jasco\",\"FP-8500\",15,\"Fluorescence\",\"\"],\n[\"Jasco\",\"FP-8600\",15,\"Fluorescence\",\"\"],\n[\"Jasco\",\"J-810 Peltier\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"J-815 Peltier\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"V 530\",12.0,\"UV-Vis\",\"Standard, Halbmikro (Z=12), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"V 550\",12.0,\"UV-Vis\",\"Standard, Halbmikro (Z=12), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"V 560\",12.0,\"UV-Vis\",\"Standard, Halbmikro (Z=12), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"V 570\",12.0,\"UV-Vis\",\"Standard, Halbmikro (Z=12), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"V 630\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"V 650\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"V 660\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"V 670\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jasco\",\"V-530\",12,\"UV-Vis\",\"\"],\n[\"Jasco\",\"V-550\",12,\"UV-Vis\",\"\"],\n[\"Jasco\",\"V-560\",12,\"UV-Vis\",\"\"],\n[\"Jasco\",\"V-570\",12,\"UV-Vis\",\"\"],\n[\"Jasco\",\"V-630\",15,\"UV-Vis\",\"\"],\n[\"Jasco\",\"V-650\",15,\"UV-Vis\",\"\"],\n[\"Jasco\",\"V-660\",15,\"UV-Vis\",\"\"],\n[\"Jasco\",\"V-670\",15,\"UV-Vis-NIR\",\"\"],\n[\"Jasco\",\"V-770\",15,\"UV-Vis-NIR\",\"\"],\n[\"Jasco\",\"V-780\",15,\"UV-Vis-NIR\",\"\"],\n[\"Jenway\",\"6100 Vis\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jenway\",\"6105 UV\/Vis\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jenway\",\"6200 F\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jenway\",\"6300\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jenway\",\"6305\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jenway\",\"6400\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jenway\",\"6405\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jenway\",\"6500\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jenway\",\"6505\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jenway\",\"Genova\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jobin\",\"FluoroLog\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jobin\",\"FluoroMax\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Jobin\",\"Yvon 101\",12.0,\"UV-Vis\",\"Standard, Halbmikro (Z=12), Langweg-K\u00fcvetten\"],\n[\"Jobin\",\"Yvon 201\",12.0,\"UV-Vis\",\"Standard, Halbmikro (Z=12), Langweg-K\u00fcvetten\"],\n[\"Kruess AG\",\"UV 6500\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"L.O.T Oriel\",\"Smar Plus 2605\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"L.O.T Oriel\",\"Smar Plus 3255\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Macherey-Nagel\",\"Namcolor SM 1\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Malvern\",\"Zetasizer\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Mettler-Toledo\",\"UV5\",15,\"UV-Vis\",\"\"],\n[\"Mettler-Toledo\",\"UV5Bio\",15,\"UV-Vis\",\"\"],\n[\"Mettler-Toledo\",\"UV7\",15,\"UV-Vis\",\"\"],\n[\"Micronal\",\"B 542\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Micronal\",\"B 572\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Micronal\",\"B 582\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Molecular Devices\",\"SpectraMax\",15.87,\"UV-Vis\",\"\"],\n[\"Ocean Optics\",\"USB 2000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Ocean Optics\",\"USB2000\",15,\"UV-Vis\",\"\"],\n[\"Ocean Optics\",\"USB2000+\",15,\"UV-Vis\",\"\"],\n[\"Ocean Optics\",\"USB4000\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Bio 20\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"PerkinElmer\",\"Bio 40\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"PerkinElmer\",\"Lambda 10\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Lambda 1050\",15,\"UV-Vis-NIR\",\"\"],\n[\"PerkinElmer\",\"Lambda 11\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Lambda 12\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Lambda 14\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Lambda 2\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Lambda 20\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Lambda 25\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Lambda 35\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Lambda 40\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Lambda 45\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Lambda 650\",15,\"UV-Vis\",\"\"],\n[\"PerkinElmer\",\"Lambda 750\",15,\"UV-Vis-NIR\",\"\"],\n[\"PerkinElmer\",\"Lambda 800\",15,\"UV-Vis-NIR\",\"\"],\n[\"PerkinElmer\",\"Lambda 850\",15,\"UV-Vis-NIR\",\"\"],\n[\"PerkinElmer\",\"Lambda 900\",15,\"UV-Vis-NIR\",\"\"],\n[\"PerkinElmer\",\"Lambda 950\",15,\"UV-Vis-NIR\",\"\"],\n[\"PerkinElmer\",\"PE 1000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"PerkinElmer\",\"PE 3000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"PerkinElmer\",\"PE 55 B\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"PerkinElmer\",\"PE 552\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"PerkinElmer\",\"PE 554\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"PerkinElmer\",\"PE 555\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"PerkinElmer\",\"PE 650-10\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"PerkinElmer\",\"PE 650-40\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"PerkinElmer\",\"PE LS 50\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Pharmacia\",\"All Types of Pharmacia\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Pilips\",\"PU 8100\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Pilips\",\"PU 8600\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Pilips\",\"PU 8625\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Pilips\",\"PU 8700\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Pilips\",\"PU 8720\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"PTI\",\"QM6SE\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Riele\",\"MK 40\",8.35,\"UV-Vis\",\"\"],\n[\"Riele\",\"PM 210\",9.0,\"UV-Vis\",\"\"],\n[\"Riele\",\"PM 310\",9.0,\"UV-Vis\",\"\"],\n[\"Riele\",\"PM 750\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Safas\",\"2000 D\",16.5,\"UV-Vis\",\"\"],\n[\"Safas\",\"UV-mc\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Saitron\",\"901 Photometer\",12.5,\"UV-Vis\",\"\"],\n[\"Sartorius\",\"VivaSpec LS\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Scinco\",\"All Types of Scinco\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Seac\",\"CH-100\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Seac\",\"S 263\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Seac\",\"S 266\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Secomam\",\"Prim\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Secomam\",\"S 1000 G 2 UV\/Vis\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Secomam\",\"S 1000 PC UV\/Vis\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Secomam\",\"S 250 I Vis\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Secomam\",\"S 500 I Vis\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Secomam\",\"S 500 P Vis\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Secomam\",\"S 750 I UV\/Vis\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"QR 50\",17.0,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"QV 50\",20.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=20), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"RF 1501\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"RF 500\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"RF 5001\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"RF 510\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"RF 5301\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"RF 551 S\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"RF-5301PC\",15,\"Fluorescence\",\"\"],\n[\"Shimadzu\",\"RF-6000\",15,\"Fluorescence\",\"\"],\n[\"Shimadzu\",\"UV 120\",12,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"UV 1200\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 1201\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 1202\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 1240\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 140\",12.5,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"UV 150\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 160\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 1600\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 1601\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 1602\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 1603\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 1700\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 180\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 190\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 200\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 2101\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 240\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 2401\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 2402\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 2403\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 2501\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 2502\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 2503\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 260\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 265\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 265 FS\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 300\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 3101\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 3102\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 3103\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 350\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV 364\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV mini 12400\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV Multispec 1500\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Shimadzu\",\"UV-1280\",15,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"UV-1800\",15,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"UV-1900\",15,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"UV-1900i\",15,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"UV-2450\",15,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"UV-2550\",15,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"UV-2600\",15,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"UV-2600i\",15,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"UV-2700\",15,\"UV-Vis\",\"\"],\n[\"Shimadzu\",\"UV-3600\",15,\"UV-Vis-NIR\",\"\"],\n[\"Shimadzu\",\"UV-3600 Plus\",15,\"UV-Vis-NIR\",\"\"],\n[\"Shimadzu\",\"UV-3600i Plus\",15,\"UV-Vis-NIR\",\"\"],\n[\"Spectronics\",\"All Types of Spectronics\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Technikon\",\"Autoanalyser\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"AquaMate\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"BioMate 3\",8.5,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"BioMate 3S\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"BioMate 5\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"BioMate 6\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Evolution 100\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Evolution 160\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Evolution 201\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Evolution 220\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Evolution 300\",8.5,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Evolution 300 UV\/Vis\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Evolution 60\",8.5,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Evolution 600\",8.5,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Evolution 60S\",8.5,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Evolution Array\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Genesys\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Genesys (older S series)\",8.5,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"GENESYS 10S\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"GENESYS 150\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"GENESYS 20\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"GENESYS 30\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"GENESYS 50\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Genesys S Series\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Genova\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Helios Alpha\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Helios Beta\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Helios Gamma\",15,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Multiskan Sepctrum\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"PU 25\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"SP 1700\",17.0,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"SP 1800\",13.0,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"SP 30\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"SP 500\",17.0,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"SP 600\",13.0,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"SP 620\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"SP 700\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"SP 800\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"SP 820\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic 1001\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic 1201\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic 200\",14.5,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Spectronic 200 UV\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic 2000\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic 300-500\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic 3000 Array\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic 600\",16.0,\"UV-Vis\",\"\"],\n[\"Thermo Scientific\",\"Spectronic 601\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic 700\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic ATI 5625\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic Genesis 10\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic Genesis 2\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic Genesis 20\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic Genesis 5\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"Spectronic Genesis 8\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"thermospec ABC\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"UV-1\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"UV-10\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"UV-2\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"UV-3\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Thermo Scientific\",\"UV-4\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Transasia\",\"Erba Chem-5\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Walden\",\"WPA S 2000\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Whatmann\",\"Gene Ray UV-Photometer\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Specord M 40\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Specord M 500\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Specord M 80\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Specord M 85\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Specord S 10 VIS\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Specord S 100\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Specord S 5 UV\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Specord S 5 VIS\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Spekol 11\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Spekol 210\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Spekol 211\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Spekol 220\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Zeiss\",\"Spekol 221\",8.5,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=8,5), Langweg-K\u00fcvetten\"],\n[\"Zuzi\",\"4418\/2\\\"\",15.0,\"UV-Vis\",\"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\"]\n];\n\n\nvar COMPAT15=[\n  {n:\"Standard-10-mm-K\u00fcvette\",d:\"Alle Standard-K\u00fcvetten mit 1 cm Schichtdicke\",s:\"ok\"},\n  {n:\"Halbmikrok\u00fcvette\",d:\"Reduziertes Volumen, 1,4\u20133,5 mL\",s:\"ok\"},\n  {n:\"Mikrok\u00fcvette (Z=15)\",d:\"70\u2013400 \u00b5L Volumen\",s:\"ok\"},\n  {n:\"Langweg-K\u00fcvette\",d:\"20 mm, 50 mm, 100 mm Schichtdicke\",s:\"ok\"},\n  {n:\"Durchflussk\u00fcvette\",d:\"Kontinuierlicher oder Stopped-Flow\",s:\"ok\"},\n  {n:\"Sub-Mikro-K\u00fcvette (Z=8,5)\",d:\"Braucht Distanzadapter f\u00fcr Z=15-Ger\u00e4te\",s:\"warn\"}\n];\nvar COMPAT85=[\n  {n:\"Sub-Mikro-K\u00fcvette (Z=8,5)\",d:\"50\u2013150 \u00b5L, f\u00fcr Z=8,5 konzipiert\",s:\"ok\"},\n  {n:\"Mikrok\u00fcvette (Z=8,5)\",d:\"100-350 uL\",s:\"ok\"},\n  {n:\"Standardk\u00fcvette + Adapter\",d:\"Distanzst\u00fcck hebt effektives Z auf 15 mm\",s:\"warn\"},\n  {n:\"Standard 10 mm (ohne Adapter)\",d:\"Strahl verfehlt das optische Fenster\",s:\"no\"}\n];\n\nfunction getC(z){return z===8.5?COMPAT85:z===15?COMPAT15:null;}\nfunction getCT(z){\n  if(z===15){return \"Standard, Halbmikro, Mikro (Z=15), Langweg-K\u00fcvetten\";}\n  if(z===8.5){return \"Sub-Mikro Z=8,5, Mikro Z=8,5 (Standard braucht Adapter)\";}\n  return \"\";\n}\nfunction getTC(t){\n  if(t===\"UV-Vis\")return \"bt bt-uv\";\n  if(t===\"UV-Vis-NIR\")return \"bt bt-nir\";\n  if(t===\"Fluorescence\")return \"bt bt-fl\";\n  return \"bt bt-uv\";\n}\n\nfunction init(){\n  var brands=[...new Set(DB.map(function(d){return d[0]}))].sort();\n  var sel=document.getElementById(\"zp-brand\");\n  brands.forEach(function(b){var o=document.createElement(\"option\");o.value=o.text=b;sel.appendChild(o);});\n  renderTable(\"all\");\n  document.getElementById(\"zp-count\").textContent=\"(\"+DB.length+\" instruments)\";\n}\n\nfunction zpBrand(){document.getElementById(\"zp-res\").className=\"zp-res\";}\n\nfunction zpHint(){\n  var q=document.getElementById(\"zp-model\").value.trim().toLowerCase();\n  if(q.length<2){document.getElementById(\"zp-hint\").textContent=\"\";return;}\n  var n=DB.filter(function(d){return d[1].toLowerCase().includes(q)||d[0].toLowerCase().includes(q);}).length;\n  document.getElementById(\"zp-hint\").textContent=n?n+\" match\"++\" gefunden\":\"Keine Treffer gefunden\";\n}\n\nfunction zpLookup(){\n  var brand=document.getElementById(\"zp-brand\").value;\n  var model=document.getElementById(\"zp-model\").value.trim();\n  if(!brand&&!model){alert(\"Bitte w\u00e4hlen Sie eine Marke oder geben Sie einen Modellnamen ein.\");return;}\n  var m=DB.filter(function(d){\n    var bm=!brand||d[0]===brand;\n    var mm=!model||d[1].toLowerCase().includes(model.toLowerCase());\n    return bm&&mm;\n  });\n  if(!m.length){showNA(\"Kein Treffer gefunden. <a href=\\\"\/contact\/\\\" style=\\\"color:#233a95;font-weight:600\\\">Kontaktieren Sie uns<\/a> mit Ihrem Ger\u00e4temodell und wir best\u00e4tigen das Z-Ma\u00df.\");return;}\n  var exact=m.find(function(d){return d[1].toLowerCase()===model.toLowerCase();});\n  showResult(exact||m[0],m.length);\n}\n\nfunction showResult(d,total){\n  var r=document.getElementById(\"zp-res\");\n  var badge=document.getElementById(\"zp-badge\");\n  badge.textContent=d[2]!==null?d[2]+\" mm\":\"N\/A\";\n  badge.className=d[2]===8.5?\"res-badge warn\":\"res-badge\";\n  document.getElementById(\"zp-name\").textContent=d[0]+\" \"+d[1];\n  document.getElementById(\"zp-sub\").textContent=d[3]+(total>1?\" - \"+total+\" Modelle passen, bestes Ergebnis wird gezeigt\":\"\");\n  r.className=d[2]===8.5?\"zp-res show warn\":\"zp-res show\";\n  var cg=document.getElementById(\"zp-cg\");\n  var compat=getC(d[2]);\n  if(compat){\n    cg.innerHTML=compat.map(function(c){\n      var label=c.s===\"ok\"?\"Kompatibel\":c.s===\"warn\"?\"Mit Adapter\":\"Nicht kompatibel\";\n      return \"<div class=\\\"cc \"+c.s+\"\\\"><div class=\\\"cc-t\\\">\"+c.n+\"<\/div><div class=\\\"cc-d\\\">\"+c.d+\"<\/div>\"\n        +\"<span class=\\\"cc-tag \"+c.s+\"\\\">\"+label+\"<\/span><\/div>\";\n    }).join(\"\");\n  } else {cg.innerHTML=\"\";}\n  var tip=document.getElementById(\"zp-tip\");\n  if(d[2]===8.5){\n    tip.style.display=\"block\";\n    tip.innerHTML=\"<strong>8,5-mm-Niedrig-Z-Ger\u00e4t:<\/strong> Z = 8,5 mm Strahlh\u00f6he. Bestellen Sie K\u00fcvetten, die speziell mit Z = 8,5 mm spezifiziert sind. Standardk\u00fcvetten (Z = 15 mm) ohne Adapter lassen den Strahl oberhalb oder durch den falschen Teil der K\u00fcvette laufen.\";\n  } else {tip.style.display=\"none\";}\n}\n\nfunction showNA(msg){\n  var r=document.getElementById(\"zp-res\");\n  r.className=\"zp-res show na\";\n  document.getElementById(\"zp-badge\").textContent=\"?\";\n  document.getElementById(\"zp-badge\").className=\"res-badge warn\";\n  document.getElementById(\"zp-name\").textContent=\"Ger\u00e4t nicht gefunden\";\n  document.getElementById(\"zp-sub\").innerHTML=msg;\n  document.getElementById(\"zp-cg\").innerHTML=\"\";\n  document.getElementById(\"zp-tip\").style.display=\"none\";\n}\n\nfunction zpToggle(){\n  window._zpShowAll=!window._zpShowAll;\n  renderTable(window._zpFilter||\"all\");\n}\nfunction renderTable(filter){\n  var rows=DB.filter(function(d){\n    if(filter===\"all\")return true;\n    if(filter===\"UV-Vis\")return d[3]===\"UV-Vis\";\n    if(filter===\"UV-Vis-NIR\")return d[3]===\"UV-Vis-NIR\";\n    if(filter===\"Fluorescence\")return d[3]===\"Fluorescence\";\n    if(filter===\"z15\")return d[2]===15;\n    if(filter===\"z85\")return d[2]===8.5;\n    if(filter===\"z20\")return d[2]===20;\n    return true;\n  });\n  var showAll=window._zpShowAll||false;\n  var displayed=showAll?rows:rows.slice(0,20);\n  var html=displayed.map(function(d){\n    var zc=d[2]===null?\"<td class=\\\"zna\\\">N\/A<\/td>\":\"<td class=\\\"zv\"+(d[2]===8.5?\" w\":\"\")+\"\\\">\"+(d[2])+\" mm<\/td>\";\n    var cp=d[2]?\"<td style=\\\"font-size:12px;color:#555\\\">\"+getCT(d[2])+\"<\/td>\":\"<td class=\\\"zna\\\">-<\/td>\";\n    return \"<tr><td><strong>\"+d[0]+\"<\/strong><\/td><td>\"+d[1]+\"<\/td><td><span class=\\\"\"+getTC(d[3])+\"\\\">\"+d[3]+\"<\/span><\/td>\"+zc+cp+\"<\/tr>\";\n  }).join(\"\");\n  document.getElementById(\"zp-tb\").innerHTML=html;\n  document.querySelector(\"table.zt\").style.display=rows.length?\"\":\"none\";\n  document.getElementById(\"zp-nores\").style.display=rows.length?\"none\":\"block\";\n  document.getElementById(\"zp-count\").textContent=\"(\"+rows.length+\" of \"+DB.length+\")\";\n  var togDiv=document.getElementById(\"zp-toggle\");\n  if(togDiv){\n    if(rows.length>20){\n      togDiv.style.display=\"block\";\n      togDiv.innerHTML=showAll\n        ?\"<button class=\\\"zp-toggle-btn\\\" onclick=\\\"zpToggle()\\\">Weniger anzeigen \u25b2<\/button>\"\n        :\"<button class=\\\"zp-toggle-btn\\\" onclick=\\\"zpToggle()\\\">Alle \"+rows.length+\" Ger\u00e4te anzeigen \u25bc<\/button>\";\n    }else{\n      togDiv.style.display=\"none\";\n    }\n  }\n}\n\nfunction zpFilter(btn,f){\n  window._zpShowAll=false;\n  window._zpFilter=f;\n  document.querySelectorAll(\".fb-btn\").forEach(function(b){b.classList.remove(\"active\");});\n  btn.classList.add(\"active\");\n  renderTable(f);\n}\n\ndocument.querySelectorAll(\".zd-faq-q\").forEach(function(q){\n  q.addEventListener(\"click\",function(){\n    var item=this.closest(\".zd-faq-item\");\n    var isOpen=item.classList.contains(\"open\");\n    document.querySelectorAll(\".zd-faq-item\").forEach(function(i){i.classList.remove(\"open\");});\n    if(!isOpen)item.classList.add(\"open\");\n  });\n});\n\ninit();\n<\/script>\n\n\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Was ist das Standard-Z-Ma\u00df f\u00fcr UV-Vis-K\u00fcvetten?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Das ISO-Standard-Z-Ma\u00df f\u00fcr UV-Vis-Spektrophotometer-K\u00fcvetten ist 15 mm. Es wird von Agilent (Cary), Shimadzu, Thermo Scientific, Jasco, Hitachi, Mettler-Toledo und den meisten anderen Ger\u00e4temarken verwendet. Die 8,5-mm-Niedrig-Z-Ausnahme findet sich bei der Beckman-DU-Serie, Eppendorf-Photometern und diversen klinischen und \u00e4lteren Analyseger\u00e4ten.\"}}, {\"@type\": \"Question\", \"name\": \"Woher wei\u00df ich, ob mein Ger\u00e4t Z = 8,5 mm K\u00fcvetten braucht?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"If your instrument is a PerkinElmer Lambda 25, 35, 45, 650, 750, 850, 950, or 1050, it requires Z = 8.5 mm cuvettes. All other PerkinElmer models typically use Z = 15 mm. When in doubt, use the lookup tool on this page or consult your instrument manual under cuvette specifications.\"}}, {\"@type\": \"Question\", \"name\": \"Kann ich eine Standard-10-mm-K\u00fcvette in einem Beckman DU 800 verwenden?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Not directly. A standard 10 mm path length cuvette has Z = 15 mm. The Lambda 650 uses Z = 8.5 mm, so the beam will strike above the optical window, producing no signal. Use a dedicated sub-micro or micro cuvette rated Z = 8.5 mm, or a spacer adapter.\"}}, {\"@type\": \"Question\", \"name\": \"Was ist der Unterschied zwischen Z-Ma\u00df und Schichtdicke?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Path length is the horizontal distance the light beam travels through the sample \u2014 typically 10 mm. Z dimension is the vertical height of the beam above the instrument base plate. They are independent specifications. A cuvette with 10 mm path length can exist in both Z=15 mm and Z=8.5 mm versions.\"}}, {\"@type\": \"Question\", \"name\": \"Kann MachinedQuartz K\u00fcvetten mit einem Sonder-Z-Ma\u00df fertigen?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. MachinedQuartz can manufacture quartz cuvettes to any specified Z dimension with \u00b10.1 mm tolerance. Lead time is typically 5-8 business days for sintered and standard grades, approximately 30 days for molded designs.\"}}, {\"@type\": \"Question\", \"name\": \"Spielt das Z-Ma\u00df f\u00fcr Fluoreszenzk\u00fcvetten eine Rolle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. A fluorescence spectrophotometer has two beam paths \u2014 excitation and emission at 90 degrees. Both have a Z dimension that must match the cuvette window position. Most fluorescence instruments use Z = 15 mm for both axes.\"}}], \"inLanguage\": \"de\"}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Z-Ma\u00df von Spektrophotometer-K\u00fcvetten \u2013 15 mm vs 8,5 mm, PerkinElmer-Lambda, Nachschlag-Tool (154+ Ger\u00e4te), Z-Fehlanpassung beheben.<\/p>\n","protected":false},"author":1,"featured_media":85474,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-98169","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/pages\/98169","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/comments?post=98169"}],"version-history":[{"count":7,"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/pages\/98169\/revisions"}],"predecessor-version":[{"id":98640,"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/pages\/98169\/revisions\/98640"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/media\/85474"}],"wp:attachment":[{"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/media?parent=98169"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}