{"id":98491,"date":"2026-05-15T12:55:00","date_gmt":"2026-05-15T04:55:00","guid":{"rendered":"https:\/\/machinedquartz.com\/nir-quarzkuevetten-jgs3\/"},"modified":"2026-06-11T09:14:35","modified_gmt":"2026-06-11T01:14:35","slug":"nir-quarzkuevetten-jgs3","status":"publish","type":"post","link":"https:\/\/machinedquartz.com\/de\/nir-quarzkuevetten-jgs3\/","title":{"rendered":"NIR-Quarzk\u00fcvetten f\u00fcr die Spektroskopie von 700\u20132.500 nm"},"content":{"rendered":"\n<style>\n.cq-page { max-width: 860px; margin: 0 auto; padding: 0 20px; font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", sans-serif; color: #1e293b; }\n.cq-page p, .cq-page li { font-size: 16px; line-height: 1.7; }\n.cq-section { margin-bottom: 56px; }\n.cq-section h2 { font-size: 26px; font-weight: 700; color: #5b21b6; margin-bottom: 18px; line-height: 1.3; }\n.cq-section h3 { font-size: 19px; font-weight: 600; color: #6d28d9; margin: 24px 0 10px; }\n.cq-section-label { font-size: 11px; font-weight: 700; letter-spacing: 2px; text-transform: uppercase; color: #6d28d9; margin-bottom: 8px; }\n\n.cq-hero { background: linear-gradient(135deg, #4c1d95 0%, #6d28d9 60%, #8b5cf6 100%); border-radius: 16px; padding: 50px 36px; text-align: center; color: #fff; margin-bottom: 48px; }\n.cq-hero-eyebrow { font-size: 12px; font-weight: 600; letter-spacing: 2px; text-transform: uppercase; color: #ddd6fe; margin-bottom: 14px; }\n.cq-hero-h1 { font-size: clamp(26px, 4vw, 40px); font-weight: 700; line-height: 1.2; margin: 0 0 16px; color: #fff; }\n.cq-hero p.cq-hero-sub { font-size: 16px; color: #ede9fe; max-width: 640px; margin: 0 auto 28px; line-height: 1.6; }\n.cq-stats { display: grid; grid-template-columns: repeat(4, 1fr); gap: 0; background: rgba(255,255,255,0.08); border-radius: 10px; margin-top: 24px; }\n.cq-stat { padding: 16px 10px; border-right: 1px solid rgba(255,255,255,0.12); }\n.cq-stat:last-child { border-right: none; }\n.cq-stat-num { font-size: 20px; font-weight: 700; color: #fff; line-height: 1.1; }\n.cq-stat-label { font-size: 10px; color: #ddd6fe; text-transform: uppercase; letter-spacing: 1px; margin-top: 4px; }\n\n.cq-aidef { background: #faf5ff; border: 1px solid #d8b4fe; border-radius: 10px; padding: 18px 22px; margin: 0 0 24px; }\n.cq-aidef p { margin: 0; font-size: 16px; line-height: 1.65; color: #1e293b; }\n.cq-aidef strong { color: #5b21b6; }\n\n.cq-tldr { background: #f5f3ff; border-left: 4px solid #6d28d9; padding: 18px 22px; border-radius: 6px; margin-bottom: 36px; font-size: 15px; line-height: 1.65; }\n.cq-tldr strong { color: #4c1d95; }\n.cq-hl { background: #fef3c7; padding: 1px 5px; border-radius: 3px; }\n\n.cq-tbl-wrap { overflow-x: auto; margin: 16px 0 24px; }\ntable.cq-tbl { width: 100%; border-collapse: collapse; font-size: 14px; }\ntable.cq-tbl th { background: #4c1d95; color: #fff; padding: 11px 12px; text-align: left; font-weight: 600; }\ntable.cq-tbl td { padding: 11px 12px; border-bottom: 1px solid #e5e7eb; vertical-align: top; }\ntable.cq-tbl tr:nth-child(even) td { background: #faf5ff; }\n\n.cq-app-grid { display: grid; grid-template-columns: repeat(2, 1fr); gap: 16px; margin: 20px 0; }\n.cq-app-card { background: #f7f5fa; border-radius: 10px; padding: 22px; border-top: 3px solid #8b5cf6; transition: background 0.2s, transform 0.15s; }\n.cq-app-card:hover { background: #4c1d95; transform: translateY(-3px); }\n.cq-app-card h3 { color: #1a1a2e; margin-top: 0; transition: color 0.2s; }\n.cq-app-card:hover h3 { color: #fff; }\n.cq-app-card p { color: #475569; font-size: 14px; margin: 8px 0 0; transition: color 0.2s; }\n.cq-app-card:hover p { color: rgba(255,255,255,0.9); }\n.cq-app-card .cq-app-tag { display: inline-block; font-size: 10px; font-weight: 700; padding: 2px 8px; border-radius: 4px; background: #ede9fe; color: #5b21b6; text-transform: uppercase; letter-spacing: 0.5px; margin-bottom: 8px; transition: background 0.2s, color 0.2s; }\n.cq-app-card:hover .cq-app-tag { background: rgba(255,255,255,0.18); color: #ddd6fe; }\n\ntable.cq-sku { width: 100%; border-collapse: collapse; font-size: 13px; margin: 14px 0; }\ntable.cq-sku th, table.cq-sku td { padding: 9px 10px; border-bottom: 1px solid #e5e7eb; text-align: left; }\ntable.cq-sku th { background: #f3eeff; color: #4c1d95; font-weight: 700; }\ntable.cq-sku td:first-child { font-family: monospace; color: #6d28d9; font-weight: 600; }\n\n.cq-decision { background: #fef3c7; border: 1px solid #fcd34d; border-radius: 10px; padding: 18px 22px; margin: 18px 0; }\n.cq-decision strong { color: #92400e; }\n\n.cq-cta { background: linear-gradient(135deg, #4c1d95, #7c3aed); border-radius: 12px; padding: 30px 28px; text-align: center; color: #fff; margin: 40px 0; }\n.cq-cta h3 { color: #fff; font-size: 20px; margin: 0 0 10px; }\n.cq-cta p { color: #ddd6fe; margin: 0 0 18px; font-size: 15px; }\n.cq-cta a.cq-btn { display: inline-block; background: #fff; color: #4c1d95; padding: 12px 28px; border-radius: 8px; font-weight: 700; text-decoration: none; transition: background 0.15s, transform 0.15s; }\n.cq-cta a.cq-btn:hover { background: #f3eeff; transform: translateY(-1px); }\n.cq-cta a.cq-btn-2 { background: transparent; color: #fff; border: 2px solid rgba(255,255,255,0.5); margin-left: 10px; }\n.cq-cta a.cq-btn-2:hover { background: rgba(255,255,255,0.1); }\n\n.cq-faq-item { border-bottom: 1px solid #e5e7eb; }\n.cq-faq-q { display: flex; justify-content: space-between; align-items: center; padding: 16px 0; cursor: pointer; font-weight: 600; color: #4c1d95; font-size: 16px; }\n.cq-faq-q::after { content: '+'; font-size: 22px; color: #94a3b8; transition: transform 0.2s; }\n.cq-faq-item.open .cq-faq-q::after { content: '\u2212'; }\n.cq-faq-a { max-height: 0; overflow: hidden; transition: max-height 0.3s ease; color: #475569; font-size: 15px; line-height: 1.65; }\n.cq-faq-item.open .cq-faq-a { max-height: 600px; padding-bottom: 18px; }\n\n@media (max-width: 600px) {\n  .cq-app-grid { grid-template-columns: 1fr; }\n  .cq-stats { grid-template-columns: repeat(2, 1fr); }\n  .cq-stat { border-right: none; border-bottom: 1px solid rgba(255,255,255,0.12); }\n}\n<\/style>\n\n<div class=\"cq-page\">\n\n<!-- HERO -->\n<div class=\"cq-hero\">\n  <div class=\"cq-hero-eyebrow\">NIR-Quarzk\u00fcvetten<\/div>\n  <p class=\"cq-hero-h1\">NIR-Quarzk\u00fcvetten f\u00fcr die Spektroskopie von 700\u20132.500 nm<\/p>\n  <p class=\"cq-hero-sub\">Quarzk\u00fcvetten der JGS3-Qualit\u00e4t, optimiert f\u00fcr das Nahinfrarot-Fenster: Getreidefeuchte-Analysatoren, pharmazeutische Rohstoffidentifizierung, Polymerfolien-QC und biomedizinische NIR. Wo Standard-JGS1 auf OH-Absorption trifft, bleibt JGS3 bis 3.500 nm transparent.<\/p>\n  <div class=\"cq-stats\">\n    <div class=\"cq-stat\"><div class=\"cq-stat-num\">700\u20132.500 nm<\/div><div class=\"cq-stat-label\">NIR-Fenster<\/div><\/div>\n    <div class=\"cq-stat\"><div class=\"cq-stat-num\">JGS3-Qualit\u00e4t<\/div><div class=\"cq-stat-label\">OH-freies Quarzglas<\/div><\/div>\n    <div class=\"cq-stat\"><div class=\"cq-stat-num\">0,5\u201350 mm<\/div><div class=\"cq-stat-label\">Schichtdicke<\/div><\/div>\n    <div class=\"cq-stat\"><div class=\"cq-stat-num\">2-Wege \/ 4-Wege<\/div><div class=\"cq-stat-label\">Lichtgeometrie<\/div><\/div>\n  <\/div>\n<\/div>\n\n<!-- AI-QUOTABLE OPENING -->\n<div class=\"cq-aidef\">\n<p><strong style=\"color:#5b21b6;\">Eine NIR-Quarzk\u00fcvette ist<\/strong> eine K\u00fcvette f\u00fcr die Nahinfrarot-Spektroskopie aus Quarzglas der JGS3-Qualit\u00e4t, transparent von etwa 260 nm bis 3.500 nm. Sie deckt das gesamte NIR-Fenster (700\u20132.500 nm) ohne den OH-Absorptionseinbruch bei 2.200 nm ab, der Standard-JGS1\/JGS2-K\u00fcvetten begrenzt. NIR-K\u00fcvetten werden in Getreidefeuchte-Analysatoren, der pharmazeutischen Rohstoffidentifizierung (PAT), der Messung von Polymerfolien-Dicken und der biomedizinischen Gewebespektroskopie eingesetzt, mit Schichtdicken von typischerweise 1\u201310 mm, um die Signalst\u00e4rke gegen die starken NIR-Wasserbanden auszubalancieren.<\/p>\n<\/div>\n\n<!-- TL;DR -->\n<div class=\"cq-tldr\">\n<strong>TL;DR: Wann Sie eine dedizierte NIR-K\u00fcvette brauchen, nicht irgendeine Quarzk\u00fcvette:<\/strong>\nNIR \u00fcberlappt mit den Wasser- und OH-Absorptionspeaks bei 1.440 nm und 1.940 nm, Banden, die <span class=\"cq-hl\">JGS3-Quarz sauber bew\u00e4ltigt<\/span> w\u00e4hrend <span class=\"cq-hl\">JGS1 und JGS2 verzerren<\/span>. Wenn Sie einen Foss, Buchi NIRFlex, MicroNIR oder einen beliebigen Prozess-NIR-Analysator \u00fcber 1.200 nm betreiben und eine schr\u00e4ge Basislinie sehen, ist das K\u00fcvettenmaterial der erste Verd\u00e4chtige. JGS3-K\u00fcvetten werden auf Bestellung gefertigt, mit 4\u20136 Wochen Lieferzeit.\n<\/div>\n\n<!-- WHAT IS -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">Materialwahl<\/div>\n<h2>Warum JGS3-Quarz, nicht JGS1 oder JGS2<\/h2>\n\n<p>Die drei Quarzmaterialien optischer Qualit\u00e4t sehen f\u00fcr das Auge identisch aus, haben aber im Infraroten sehr unterschiedliche Transmissionsprofile. Der entscheidende Unterschied ist der OH-Gehalt (Hydroxyl) der Schmelze, und OH absorbiert stark bei 2,2 \u00b5m (2.200 nm), mitten im NIR-Fenster.<\/p>\n\n<div class=\"cq-tbl-wrap\">\n<figure style=\"margin:30px 0;text-align:center;\">\n<svg viewBox=\"0 0 720 320\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" style=\"max-width:100%;height:auto;background:#faf5ff;border-radius:10px;border:1px solid #d8b4fe;padding:14px;\" role=\"img\" aria-label=\"Transmissionskurven von JGS1-, JGS2- und JGS3-Quarz von 200 nm bis 3500 nm mit OH-Absorptionseinbruch bei 2200 nm in JGS1\/JGS2\">\n<text x=\"360\" y=\"22\" text-anchor=\"middle\" font-size=\"14\" font-weight=\"700\" fill=\"#5b21b6\">JGS1 vs. JGS2 vs. JGS3: Transmission \u00fcber das NIR<\/text>\n\n<!-- Axes -->\n<line x1=\"60\" y1=\"270\" x2=\"690\" y2=\"270\" stroke=\"#475569\" stroke-width=\"1.5\"\/>\n<line x1=\"60\" y1=\"50\" x2=\"60\" y2=\"270\" stroke=\"#475569\" stroke-width=\"1.5\"\/>\n<text x=\"375\" y=\"305\" text-anchor=\"middle\" font-size=\"11\" fill=\"#475569\">Wellenl\u00e4nge (nm)<\/text>\n<text x=\"22\" y=\"160\" text-anchor=\"middle\" font-size=\"11\" fill=\"#475569\" transform=\"rotate(-90 22 160)\">Transmission (%)<\/text>\n\n<!-- Y ticks -->\n<g font-size=\"9\" fill=\"#64748b\">\n<text x=\"55\" y=\"273\" text-anchor=\"end\">0<\/text>\n<line x1=\"56\" y1=\"225\" x2=\"64\" y2=\"225\"\/><text x=\"55\" y=\"228\" text-anchor=\"end\">25<\/text>\n<line x1=\"56\" y1=\"180\" x2=\"64\" y2=\"180\"\/><text x=\"55\" y=\"183\" text-anchor=\"end\">50<\/text>\n<line x1=\"56\" y1=\"135\" x2=\"64\" y2=\"135\"\/><text x=\"55\" y=\"138\" text-anchor=\"end\">75<\/text>\n<line x1=\"56\" y1=\"90\" x2=\"64\" y2=\"90\"\/><text x=\"55\" y=\"93\" text-anchor=\"end\">90<\/text>\n<\/g>\n\n<!-- X ticks: 200, 500, 1000, 1500, 2000, 2500, 3500 -->\n<g font-size=\"9\" fill=\"#64748b\">\n<line x1=\"60\" y1=\"268\" x2=\"60\" y2=\"276\"\/><text x=\"60\" y=\"288\" text-anchor=\"middle\">200<\/text>\n<line x1=\"120\" y1=\"268\" x2=\"120\" y2=\"276\"\/><text x=\"120\" y=\"288\" text-anchor=\"middle\">500<\/text>\n<line x1=\"225\" y1=\"268\" x2=\"225\" y2=\"276\"\/><text x=\"225\" y=\"288\" text-anchor=\"middle\">1000<\/text>\n<line x1=\"330\" y1=\"268\" x2=\"330\" y2=\"276\"\/><text x=\"330\" y=\"288\" text-anchor=\"middle\">1500<\/text>\n<line x1=\"435\" y1=\"268\" x2=\"435\" y2=\"276\"\/><text x=\"435\" y=\"288\" text-anchor=\"middle\">2000<\/text>\n<line x1=\"540\" y1=\"268\" x2=\"540\" y2=\"276\"\/><text x=\"540\" y=\"288\" text-anchor=\"middle\">2500<\/text>\n<line x1=\"690\" y1=\"268\" x2=\"690\" y2=\"276\"\/><text x=\"690\" y=\"288\" text-anchor=\"middle\">3500<\/text>\n<\/g>\n\n<!-- NIR band shaded region 700-2500 -->\n<rect x=\"162\" y=\"50\" width=\"378\" height=\"220\" fill=\"#a78bfa\" opacity=\"0.06\"\/>\n<text x=\"350\" y=\"68\" text-anchor=\"middle\" font-size=\"10\" fill=\"#5b21b6\" font-weight=\"600\">NIR-Fenster 700\u20132.500 nm<\/text>\n\n<!-- JGS1 curve: ~85% from 200 down to 2500 with dip at 2200 -->\n<path d=\"M 60,135 Q 100,100 120,95 L 225,92 L 330,93 L 380,95 Q 410,135 435,170 Q 460,200 470,160 L 540,120 Q 600,160 690,260\" stroke=\"#dc2626\" stroke-width=\"2.5\" fill=\"none\"\/>\n<text x=\"125\" y=\"83\" font-size=\"10\" fill=\"#dc2626\" font-weight=\"600\">JGS1 (UV)<\/text>\n\n<!-- JGS2 curve: starts at 220nm -->\n<path d=\"M 75,200 Q 95,110 120,100 L 225,95 L 330,95 L 380,98 Q 410,138 435,175 Q 460,205 470,165 L 540,125 Q 600,170 690,260\" stroke=\"#fbbf24\" stroke-width=\"2.5\" fill=\"none\" stroke-dasharray=\"6,3\"\/>\n<text x=\"200\" y=\"115\" font-size=\"10\" fill=\"#92400e\" font-weight=\"600\">JGS2 (UV-Vis)<\/text>\n\n<!-- JGS3 curve: starts at 260nm, FLAT through NIR no dip -->\n<path d=\"M 90,235 Q 110,115 130,108 L 225,102 L 330,100 L 435,100 L 540,102 L 600,108 L 660,125 L 690,180\" stroke=\"#10b981\" stroke-width=\"3\" fill=\"none\"\/>\n<text x=\"395\" y=\"115\" font-size=\"11\" fill=\"#047857\" font-weight=\"700\">JGS3 (NIR\/IR): flach bis 2500 nm \u2713<\/text>\n\n<!-- Highlight OH absorption dip -->\n<line x1=\"468\" y1=\"50\" x2=\"468\" y2=\"270\" stroke=\"#dc2626\" stroke-width=\"1\" stroke-dasharray=\"3,3\" opacity=\"0.5\"\/>\n<text x=\"468\" y=\"44\" text-anchor=\"middle\" font-size=\"9\" fill=\"#dc2626\" font-weight=\"600\">OH-Einbruch bei 2.200 nm<\/text>\n\n<\/svg>\n<figcaption style=\"font-size:12px;color:#64748b;margin-top:6px;\">JGS3 (gr\u00fcn) h\u00e4lt > 90 % Transmission \u00fcber das gesamte NIR-Fenster; JGS1 (rot) und JGS2 (gelb) fallen nahe 2.200 nm durch OH-Absorption steil ab, fatal f\u00fcr Messungen \u00fcber 1.800 nm.<\/figcaption>\n<\/figure>\n\n<table class=\"cq-tbl\">\n<thead><tr><th>Qualit\u00e4t<\/th><th>Transmissionsfenster<\/th><th>OH-Gehalt (ppm)<\/th><th>Am besten f\u00fcr<\/th><\/tr><\/thead>\n<tbody>\n<tr><td><strong>JGS1<\/strong><\/td><td>185 \u2013 2.500 nm<\/td><td>~150\u2013200<\/td><td>UV-Vis & Tief-UV; der OH-Einbruch bei 2.200 nm macht es schlecht f\u00fcr NIR > 2.000 nm<\/td><\/tr>\n<tr><td><strong>JGS2<\/strong><\/td><td>220 \u2013 2.500 nm<\/td><td>~80\u2013150<\/td><td>Standard-UV-Vis; mittleres NIR ebenfalls durch OH beeintr\u00e4chtigt<\/td><\/tr>\n<tr><td><strong>JGS3<\/strong><\/td><td>260 \u2013 3.500 nm<\/td><td>< 5<\/td><td>NIR (700\u20132.500 nm) und kurzwelliges IR (bis 3.500 nm); das NIR-K\u00fcvettenmaterial der Wahl \u2705<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>F\u00fcr einen tieferen Materialvergleich siehe unseren <a href=\"https:\/\/machinedquartz.com\/de\/uv-grenze-quarzkuevetten\/\">Leitfaden zur UV-Grenze von Quarzglas<\/a>.<\/p>\n\n<div class=\"cq-decision\">\n<strong>Entscheidungsregel:<\/strong> Liegt Ihre NIR-Messung unter ~1.800 nm und abseits der Wasserbande bei 1.440 nm, ist JGS2 brauchbar. F\u00fcr jede NIR-Arbeit \u00fcber 1.800 nm, in Prozessanalysatoren oder wo Sie eine saubere Basislinie bei 2.200 nm und dar\u00fcber brauchen, geben Sie JGS3 an.\n<\/div>\n<\/div>\n\n<!-- WHY -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">Warum es wichtig ist<\/div>\n<h2>Die Wasserbanden: was die NIR-K\u00fcvettenauswahl besonders macht<\/h2>\n\n<p>W\u00e4ssrige Proben haben im NIR zwei dominante Wasser-Absorptionspeaks: einen moderaten bei <strong>1.440 nm (1. Oberton der OH-Streckschwingung)<\/strong> und einen viel st\u00e4rkeren bei <strong>1.940 nm (Kombinationsband)<\/strong>. Diese Banden bestimmen Ihre Schichtdickenwahl grundlegend, anders als bei UV-Vis.<\/p>\n\n<div class=\"cq-tbl-wrap\">\n<figure style=\"margin:30px 0;text-align:center;\">\n<svg viewBox=\"0 0 720 280\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" style=\"max-width:100%;height:auto;background:#faf5ff;border-radius:10px;border:1px solid #d8b4fe;padding:14px;\" role=\"img\" aria-label=\"Wasser-Absorptionspeaks \u00fcber das NIR mit starken Banden bei 1440 nm und 1940 nm und \u00dcberlagerung der Transmissionsgrenzen je K\u00fcvetten-Schichtdicke\">\n<text x=\"360\" y=\"22\" text-anchor=\"middle\" font-size=\"14\" font-weight=\"700\" fill=\"#5b21b6\">NIR-Wasserbanden \u2192 Wahl der K\u00fcvetten-Schichtdicke<\/text>\n\n<!-- Axes -->\n<line x1=\"80\" y1=\"240\" x2=\"680\" y2=\"240\" stroke=\"#475569\" stroke-width=\"1.5\"\/>\n<line x1=\"80\" y1=\"50\" x2=\"80\" y2=\"240\" stroke=\"#475569\" stroke-width=\"1.5\"\/>\n<text x=\"380\" y=\"270\" text-anchor=\"middle\" font-size=\"11\" fill=\"#475569\">Wellenl\u00e4nge (nm)<\/text>\n<text x=\"32\" y=\"145\" text-anchor=\"middle\" font-size=\"11\" fill=\"#475569\" transform=\"rotate(-90 32 145)\">Wasserabsorption (10-mm-K\u00fcvette)<\/text>\n\n<!-- Y ticks -->\n<g font-size=\"9\" fill=\"#64748b\">\n<text x=\"74\" y=\"243\" text-anchor=\"end\">0<\/text>\n<line x1=\"76\" y1=\"206\" x2=\"84\" y2=\"206\"\/><text x=\"74\" y=\"209\" text-anchor=\"end\">1<\/text>\n<line x1=\"76\" y1=\"172\" x2=\"84\" y2=\"172\"\/><text x=\"74\" y=\"175\" text-anchor=\"end\">2<\/text>\n<line x1=\"76\" y1=\"138\" x2=\"84\" y2=\"138\"\/><text x=\"74\" y=\"141\" text-anchor=\"end\">3<\/text>\n<line x1=\"76\" y1=\"104\" x2=\"84\" y2=\"104\"\/><text x=\"74\" y=\"107\" text-anchor=\"end\">5<\/text>\n<line x1=\"76\" y1=\"70\" x2=\"84\" y2=\"70\"\/><text x=\"74\" y=\"73\" text-anchor=\"end\">10+<\/text>\n<\/g>\n\n<!-- X ticks 700, 1000, 1440, 1650, 1940, 2200, 2500 -->\n<g font-size=\"9\" fill=\"#64748b\">\n<line x1=\"80\" y1=\"238\" x2=\"80\" y2=\"246\"\/><text x=\"80\" y=\"258\" text-anchor=\"middle\">700<\/text>\n<line x1=\"180\" y1=\"238\" x2=\"180\" y2=\"246\"\/><text x=\"180\" y=\"258\" text-anchor=\"middle\">1000<\/text>\n<line x1=\"320\" y1=\"238\" x2=\"320\" y2=\"246\"\/><text x=\"320\" y=\"258\" text-anchor=\"middle\">1440<\/text>\n<line x1=\"395\" y1=\"238\" x2=\"395\" y2=\"246\"\/><text x=\"395\" y=\"258\" text-anchor=\"middle\">1650<\/text>\n<line x1=\"495\" y1=\"238\" x2=\"495\" y2=\"246\"\/><text x=\"495\" y=\"258\" text-anchor=\"middle\">1940<\/text>\n<line x1=\"580\" y1=\"238\" x2=\"580\" y2=\"246\"\/><text x=\"580\" y=\"258\" text-anchor=\"middle\">2200<\/text>\n<line x1=\"680\" y1=\"238\" x2=\"680\" y2=\"246\"\/><text x=\"680\" y=\"258\" text-anchor=\"middle\">2500<\/text>\n<\/g>\n\n<!-- Water absorbance curve (real shape) -->\n<path d=\"M 80,237 Q 130,235 180,224 Q 230,206 280,182 Q 310,165 320,134 Q 335,90 370,160 Q 395,200 410,210 Q 440,200 470,170 Q 490,100 510,55 Q 530,80 555,135 Q 580,118 600,135 Q 640,170 680,200\" stroke=\"#0284c7\" stroke-width=\"2.5\" fill=\"none\"\/>\n\n<!-- Linear range zones -->\n<line x1=\"80\" y1=\"206\" x2=\"680\" y2=\"206\" stroke=\"#10b981\" stroke-width=\"1\" stroke-dasharray=\"3,3\" opacity=\"0.6\"\/>\n<text x=\"685\" y=\"209\" font-size=\"9\" fill=\"#047857\">A=1 (linear OK)<\/text>\n<line x1=\"80\" y1=\"138\" x2=\"680\" y2=\"138\" stroke=\"#dc2626\" stroke-width=\"1\" stroke-dasharray=\"3,3\" opacity=\"0.6\"\/>\n<text x=\"685\" y=\"141\" font-size=\"9\" fill=\"#991b1b\">A=3 (ges\u00e4ttigt)<\/text>\n\n<!-- Annotations on key bands -->\n<circle cx=\"320\" cy=\"134\" r=\"4\" fill=\"#dc2626\"\/>\n<text x=\"320\" y=\"125\" text-anchor=\"middle\" font-size=\"9\" fill=\"#991b1b\" font-weight=\"700\">A\u22483,2 \u2192 1 mm<\/text>\n<circle cx=\"510\" cy=\"55\" r=\"4\" fill=\"#dc2626\"\/>\n<text x=\"510\" y=\"46\" text-anchor=\"middle\" font-size=\"9\" fill=\"#991b1b\" font-weight=\"700\">A\u226b10 \u2192 Submillimeter<\/text>\n<circle cx=\"580\" cy=\"118\" r=\"4\" fill=\"#dc2626\"\/>\n<text x=\"580\" y=\"109\" text-anchor=\"middle\" font-size=\"9\" fill=\"#991b1b\" font-weight=\"700\">A\u22486 \u2192 0,5\u20131 mm + JGS3<\/text>\n\n<\/svg>\n<figcaption style=\"font-size:12px;color:#64748b;margin-top:6px;\">W\u00e4ssrige NIR-Proben s\u00e4ttigen schnell: 1.940 nm (Wasser-Kombinationsband) blockiert das Licht durch jede 10-mm-K\u00fcvette. Submillimeter- und 1-mm-K\u00fcvetten sind die NIR-Norm f\u00fcr wasserhaltige Proben.<\/figcaption>\n<\/figure>\n\n<table class=\"cq-tbl\">\n<thead><tr><th>Wellenl\u00e4nge<\/th><th>Wasserabsorption durch 10-mm-K\u00fcvette<\/th><th>Folge f\u00fcr die Schichtdicke<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>900 nm (NIR-Beginn)<\/td><td>~0,05 AU<\/td><td>10 mm in Ordnung<\/td><\/tr>\n<tr><td>1.200 nm<\/td><td>~0,5 AU<\/td><td>10 mm OK<\/td><\/tr>\n<tr><td>1.440 nm (1. OH-Oberton)<\/td><td>~3,2 AU<\/td><td>1 mm f\u00fcr die Transmission n\u00f6tig<\/td><\/tr>\n<tr><td>1.650 nm<\/td><td>~0,7 AU<\/td><td>5 mm bevorzugt<\/td><\/tr>\n<tr><td>1.940 nm (Wasser-Kombinationsband)<\/td><td>> 10 AU<\/td><td>Submillimeter oder Trockenprobe messen<\/td><\/tr>\n<tr><td>2.200 nm<\/td><td>~6 AU<\/td><td>0,5\u20131 mm; JGS3 zwingend<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Deshalb verwenden die meisten kommerziellen NIR-Analysatoren standardm\u00e4\u00dfig <strong>1 mm oder k\u00fcrzer<\/strong> Schichtdicken f\u00fcr w\u00e4ssrige Proben: die H\u00e4lfte des analytischen Interesses liegt in Bereichen, in denen Wasser allein eine 10-mm-K\u00fcvette s\u00e4ttigt. F\u00fcr Trockenproben (in Transmission gemessene Pulver, Polymerfolien, Gasphase) sind l\u00e4ngere K\u00fcvetten (10\u201350 mm) Routine.<\/p>\n\n<p>F\u00fcr eine vollst\u00e4ndige Behandlung der Schichtdicke-\u00d7-Konzentration-Kompromisse siehe unsere <a href=\"https:\/\/machinedquartz.com\/de\/kuevetten-schichtdicke-nach-analyt\/\">Schichtdicken-nach-Analyt-Auswahlmatrix<\/a> und den <a href=\"https:\/\/machinedquartz.com\/de\/lambert-beersches-gesetz-kuevettenauswahl\/\">Leitfaden zum Lambert-Beerschen Gesetz<\/a>.<\/p>\n<\/div>\n\n<!-- USE CASES -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">Anwendungen<\/div>\n<h2>Sechs Bereiche, in denen NIR-Quarzk\u00fcvetten ihren Aufpreis rechtfertigen<\/h2>\n\n<div class=\"cq-app-grid\">\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">Landwirtschaft<\/span>\n    <h3>1. Getreide- & Futtermittelfeuchte<\/h3>\n    <p>Foss Infratec, Bruker MPA, Buchi NIRFlex messen Feuchte und Protein in Weizen, Mais, Soja. JGS3-5-mm-K\u00fcvetten bew\u00e4ltigen die Wasserbande bei 1.940 nm ohne S\u00e4ttigung.<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">Pharma-PAT<\/span>\n    <h3>2. Rohstoffidentifizierung<\/h3>\n    <p><a href=\"https:\/\/www.uspnf.com\/\" target=\"_blank\" rel=\"noopener\">USP <1119> NIR-ID<\/a> f\u00fcr eingehende Pharma-Materialien. Versiegelte JGS3-Probenfl\u00e4schchen lassen die QC die Identit\u00e4t durch den Deckel verifizieren, ohne Aliquotierung. Sintered-83-Fertigung f\u00fcr L\u00f6sungsmittelbest\u00e4ndigkeit.<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">Polymer<\/span>\n    <h3>3. Polymerfolien-Dicke & -Zusammensetzung<\/h3>\n    <p>Inline-NIR-Sensoren an Extrusionslinien messen die Foliendicke \u00fcber die C-H-Obertonbande bei 1.730 nm. 1\u20132-mm-Prozess-Durchflussk\u00fcvetten in JGS3 halten die Basislinie flach.<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">Biomedizin<\/span>\n    <h3>4. Gewebeoximetrie & zerebrale NIR<\/h3>\n    <p>Funktionelle NIR (fNIRS) und Gewebespektroskopie bei 760, 850, 905 nm profitieren von streulichtarmen JGS3-Referenzk\u00fcvetten f\u00fcr die Ger\u00e4tekalibrierung.<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">Erd\u00f6l<\/span>\n    <h3>5. Roh\u00f6l- & Kraftstoffzusammensetzung<\/h3>\n    <p>Oktanzahl, Wassergehalt, Biodiesel-Mischungsverh\u00e4ltnis: alles Routine auf Labor- und Inline-NIR. Versiegelte Langweg-JGS3-K\u00fcvetten (10 mm) bew\u00e4ltigen dunkles Roh\u00f6l, mit PTFE-Deckeln f\u00fcr die L\u00f6sungsmittelvertr\u00e4glichkeit.<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">Lebensmittel<\/span>\n    <h3>6. Fett-\/Zucker-\/Alkohol-QC<\/h3>\n    <p>Milchfett, Saft-Brix, Bieralkohol: NIR ersetzt nasschemische Methoden. Einweg-PE-K\u00fcvetten sind bei hohem Durchsatz \u00fcblich; JGS3-K\u00fcvetten dienen als Referenz und f\u00fcr den Kalibrierungstransfer.<\/p>\n  <\/div>\n<\/div>\n<\/div>\n\n<!-- INSTRUMENT COMPATIBILITY -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">Ger\u00e4te-Kompatibilit\u00e4t<\/div>\n<h2>Kompatibilit\u00e4t mit g\u00e4ngigen NIR-Analysatoren<\/h2>\n\n<p>NIR-Ger\u00e4te nutzen eine gr\u00f6\u00dfere Bandbreite an K\u00fcvettenformaten als UV-Vis. Passen Sie die K\u00fcvettenma\u00dfe vor der Bestellung an den Probenraum Ihres Ger\u00e4ts an:<\/p>\n\n<div class=\"cq-tbl-wrap\">\n<table class=\"cq-tbl\">\n<thead><tr><th>Ger\u00e4t<\/th><th>Wellenl\u00e4ngenbereich<\/th><th>Typisches K\u00fcvettenformat<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Foss Infratec Sofia (Getreide)<\/td><td>850\u20131.050 nm<\/td><td>modulspezifische Quarzscheibe<\/td><\/tr>\n<tr><td>Buchi NIRFlex N-500 \/ NIRMaster<\/td><td>800\u20132.500 nm<\/td><td>Fl\u00e4schchen und 10 \u00d7 10 mm K\u00fcvetten<\/td><\/tr>\n<tr><td>Bruker MPA \/ Tango \/ Matrix<\/td><td>800\u20132.500 nm<\/td><td>Standard 10 mm + modulspezifisch<\/td><\/tr>\n<tr><td>Thermo Antaris II \/ Nicolet iS50 NIR<\/td><td>800\u20132.500 nm<\/td><td>Standard 10 \u00d7 10 mm + Transmissionszubeh\u00f6r<\/td><\/tr>\n<tr><td>JDSU MicroNIR (Handger\u00e4t)<\/td><td>950\u20131.650 nm<\/td><td>Direktkontakt + Transmissionsk\u00fcvetten-Adapter<\/td><\/tr>\n<tr><td>PerkinElmer Spectrum Two N<\/td><td>1.000\u20132.500 nm<\/td><td>Standard 12,5 \u00d7 12,5 mm<\/td><\/tr>\n<tr><td>Prozess-Inline (Yokogawa, Endress)<\/td><td>1.000\u20132.500 nm<\/td><td>Sonder-Durchflussk\u00fcvette, JGS3, 1\u20135 mm Schichtdicke<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>F\u00fcr ger\u00e4tespezifische K\u00fcvettenhalter-Ma\u00dfe oder nicht standardm\u00e4\u00dfige Formfaktoren fertigt MachinedQuartz nach Zeichnung in 4\u20136 Wochen (MOQ 1). Siehe unseren <a href=\"https:\/\/machinedquartz.com\/de\/quarzkuevetten-us-lieferant-beziehen\/\">Leitfaden zum US-Hersteller<\/a> f\u00fcr den Ablauf von der Spezifikation zum Angebot.<\/p>\n<\/div>\n\n<!-- SKU TABLE -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">Produktsortiment<\/div>\n<h2>Lagernde NIR-geeignete K\u00fcvetten<\/h2>\n\n<p>Die folgenden Lager-SKUs werden standardm\u00e4\u00dfig in JGS1 oder JGS2 geliefert; JGS3-Versionen jeder davon sind mit 4\u20136 Wochen Lieferzeit verf\u00fcgbar. Geben Sie f\u00fcr echte NIR-Arbeit JGS3 in Ihrer Angebotsanfrage an.<\/p>\n\n<table class=\"cq-sku\">\n<thead><tr><th>SKU<\/th><th>Schichtdicke<\/th><th>K\u00f6rper<\/th><th>Licht<\/th><th>Beste NIR-Verwendung<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>C012CR<\/td><td>1 mm<\/td><td>Standard<\/td><td>2-Wege<\/td><td>W\u00e4ssrig nahe der Wasserbande 1.440 nm<\/td><\/tr>\n<tr><td>C022CR<\/td><td>2 mm<\/td><td>Standard<\/td><td>2-Wege<\/td><td>Leicht w\u00e4ssrig, Trockenpulver-Transmission<\/td><\/tr>\n<tr><td>C052CR<\/td><td>5 mm<\/td><td>Standard<\/td><td>2-Wege<\/td><td>Getreide- & Futtermittelfeuchte<\/td><\/tr>\n<tr><td>C102CR<\/td><td>10 mm<\/td><td>Standard<\/td><td>2-Wege<\/td><td>Trockenproben, Polymerfolien, Gasphase<\/td><\/tr>\n<tr><td>C202CR8<\/td><td>20 mm<\/td><td>20-mm-K\u00f6rper<\/td><td>2-Wege<\/td><td>Langweg-NIR, verd\u00fcnnte Proben<\/td><\/tr>\n<tr><td>C014WS3<\/td><td>1 mm<\/td><td>Durchfluss, 4 mm AD<\/td><td>4-Wege<\/td><td>Prozess-NIR mit Fluoreszenzoption<\/td><\/tr>\n<tr><td>C022WS7<\/td><td>2 mm<\/td><td>Durchfluss, 5 mm AD<\/td><td>2-Wege<\/td><td>Inline-Polymer-\/\u00d6l-\u00dcberwachung<\/td><\/tr>\n<tr><td>C034WS<\/td><td>3 mm<\/td><td>Durchfluss, 4 mm AD<\/td><td>4-Wege<\/td><td>NIR + Seitenemissions-Streuung<\/td><\/tr>\n<tr><td>Nach Zeichnung<\/td><td>0,5\u201350 mm<\/td><td>Beliebig<\/td><td>Beliebig<\/td><td>OEM-Integration; MOQ 1 in JGS3<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<p style=\"font-size: 14px; color: #64748b; margin-top: 8px;\">\u2192 Alle ansehen <a href=\"https:\/\/machinedquartz.com\/product-category\/products\/cuvettes\/infrared-ir-cuvettes\/\">IR-\/NIR-K\u00fcvetten<\/a> \u00b7 Siehe die <a href=\"https:\/\/machinedquartz.com\/cuvettes-and-cells-size-chart\/\">vollst\u00e4ndige K\u00fcvetten-Gr\u00f6\u00dfentabelle<\/a><\/p>\n<\/div>\n\n\n<div data-cq-photo-row-marker=\"1\" style=\"margin:36px 0;padding:24px 26px;background:#f8fafc;border-radius:12px;border:1px solid #e2e8f0;\">\n<div style=\"font-size:11px;font-weight:700;letter-spacing:1.5px;text-transform:uppercase;color:#475569;margin-bottom:6px;\">NIR-geeignete K\u00fcvetten am Lager<\/div>\n<h3 style=\"font-size:18px;font-weight:700;color:#1a2a6c;margin:0 0 16px;line-height:1.3;\">Vom kurzwelligen NIR bis zur Grenze des mittleren IR<\/h3>\n<div style=\"display:grid;grid-template-columns:repeat(4,1fr);gap:14px;margin-bottom:14px;\">\n<a href=\"https:\/\/machinedquartz.com\/product\/quartz-40mm-infrared-cuvette-14ml-sintered-83-two-way-light-ptfe-cap-pack-of-two-c402cr7\/\" style=\"display:block;background:#fff;border:1px solid #e2e8f0;border-radius:8px;padding:10px;text-decoration:none;transition:transform 0.15s,box-shadow 0.15s;\" onmouseover=\"this.style.transform=&#039;translateY(-2px)&#039;;this.style.boxShadow=&#039;0 6px 20px rgba(35,58,149,0.12)&#039;\" onmouseout=\"this.style.transform=&#039;translateY(0)&#039;;this.style.boxShadow=&#039;none&#039;\"><div style=\"aspect-ratio:1\/1;background:#fafafa;border-radius:6px;overflow:hidden;display:flex;align-items:center;justify-content:center;margin-bottom:8px;\"><img decoding=\"async\" src=\"https:\/\/machinedquartz.com\/wp-content\/uploads\/2025\/07\/C402CR7-40mm-Infrared-Cuvette-14ml-Two-way-Light-PTFE-Cap-Pack-of-Two.jpg\" alt=\"Quarz 40 mm Infrarot-K\u00fcvette\" loading=\"lazy\" style=\"max-width:100%;max-height:100%;object-fit:contain;\"\/><\/div><div style=\"font-family:monospace;font-size:11px;color:#233a95;font-weight:700;margin-bottom:2px;\">C402CR7<\/div><div style=\"font-size:11px;color:#475569;line-height:1.4;\">Quarz 40 mm Infrarot-K\u00fcvette<\/div><\/a>\n<a href=\"https:\/\/machinedquartz.com\/product\/quartz-40mm-infrared-cuvette-14ml-sintered-83-two-way-light-ptfe-cap-1pc-ea-c402cr6\/\" style=\"display:block;background:#fff;border:1px solid #e2e8f0;border-radius:8px;padding:10px;text-decoration:none;transition:transform 0.15s,box-shadow 0.15s;\" onmouseover=\"this.style.transform=&#039;translateY(-2px)&#039;;this.style.boxShadow=&#039;0 6px 20px rgba(35,58,149,0.12)&#039;\" onmouseout=\"this.style.transform=&#039;translateY(0)&#039;;this.style.boxShadow=&#039;none&#039;\"><div style=\"aspect-ratio:1\/1;background:#fafafa;border-radius:6px;overflow:hidden;display:flex;align-items:center;justify-content:center;margin-bottom:8px;\"><img decoding=\"async\" src=\"https:\/\/machinedquartz.com\/wp-content\/uploads\/2025\/07\/C402CR6-40mm-Infrared-Cuvette-14ml-Two-way-Light-PTFE-Cap-1pc-ea.jpg\" alt=\"Quarz 40 mm Infrarot-K\u00fcvette\" loading=\"lazy\" style=\"max-width:100%;max-height:100%;object-fit:contain;\"\/><\/div><div style=\"font-family:monospace;font-size:11px;color:#233a95;font-weight:700;margin-bottom:2px;\">C402CR6<\/div><div style=\"font-size:11px;color:#475569;line-height:1.4;\">Quarz 40 mm Infrarot-K\u00fcvette<\/div><\/a>\n<a href=\"https:\/\/machinedquartz.com\/product\/quartz-40mm-infrared-cuvette-14ml-standard-80-two-way-light-ptfe-cap-pack-of-two-c402cs7\/\" style=\"display:block;background:#fff;border:1px solid #e2e8f0;border-radius:8px;padding:10px;text-decoration:none;transition:transform 0.15s,box-shadow 0.15s;\" onmouseover=\"this.style.transform=&#039;translateY(-2px)&#039;;this.style.boxShadow=&#039;0 6px 20px rgba(35,58,149,0.12)&#039;\" onmouseout=\"this.style.transform=&#039;translateY(0)&#039;;this.style.boxShadow=&#039;none&#039;\"><div style=\"aspect-ratio:1\/1;background:#fafafa;border-radius:6px;overflow:hidden;display:flex;align-items:center;justify-content:center;margin-bottom:8px;\"><img decoding=\"async\" src=\"https:\/\/machinedquartz.com\/wp-content\/uploads\/2025\/07\/C402CS7-40mm-Infrared-Cuvette-14ml-Two-way-Light-PTFE-Cap-Pack-of-Two.jpg\" alt=\"Quarz 40 mm Infrarot-K\u00fcvette\" loading=\"lazy\" style=\"max-width:100%;max-height:100%;object-fit:contain;\"\/><\/div><div style=\"font-family:monospace;font-size:11px;color:#233a95;font-weight:700;margin-bottom:2px;\">C402CS7<\/div><div style=\"font-size:11px;color:#475569;line-height:1.4;\">Quarz 40 mm Infrarot-K\u00fcvette<\/div><\/a>\n<a href=\"https:\/\/machinedquartz.com\/product\/quartz-40mm-infrared-cuvette-14ml-standard-80-two-way-light-ptfe-cap-1pc-ea-c402cs6\/\" style=\"display:block;background:#fff;border:1px solid #e2e8f0;border-radius:8px;padding:10px;text-decoration:none;transition:transform 0.15s,box-shadow 0.15s;\" onmouseover=\"this.style.transform=&#039;translateY(-2px)&#039;;this.style.boxShadow=&#039;0 6px 20px rgba(35,58,149,0.12)&#039;\" onmouseout=\"this.style.transform=&#039;translateY(0)&#039;;this.style.boxShadow=&#039;none&#039;\"><div style=\"aspect-ratio:1\/1;background:#fafafa;border-radius:6px;overflow:hidden;display:flex;align-items:center;justify-content:center;margin-bottom:8px;\"><img decoding=\"async\" src=\"https:\/\/machinedquartz.com\/wp-content\/uploads\/2025\/07\/C402CS6-40mm-Infrared-Cuvette-14ml-Two-way-Light-PTFE-Cap-1pc-ea.jpg\" alt=\"Quarz 40 mm Infrarot-K\u00fcvette\" loading=\"lazy\" style=\"max-width:100%;max-height:100%;object-fit:contain;\"\/><\/div><div style=\"font-family:monospace;font-size:11px;color:#233a95;font-weight:700;margin-bottom:2px;\">C402CS6<\/div><div style=\"font-size:11px;color:#475569;line-height:1.4;\">Quarz 40 mm Infrarot-K\u00fcvette<\/div><\/a>\n<\/div>\n<p style=\"margin:0;font-size:13px;color:#64748b;line-height:1.55;\">Standard-JGS1\/JGS2-SKUs versenden taggleich; JGS3-Versionen jeder Geometrie sind als Sonderanfertigung in 4\u20136 Wochen verf\u00fcgbar.<\/p>\n<\/div>\n\n\n<!-- HOW TO CHOOSE -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">Auswahlhilfe<\/div>\n<h2>Die richtige NIR-K\u00fcvette w\u00e4hlen: Entscheidung in 4 Schritten<\/h2>\n\n<h3>Schritt 1: Ihren NIR-Wellenl\u00e4ngenbereich bestimmen<\/h3>\n<p>Unter 1.800 nm: JGS2 akzeptabel, JGS3 bevorzugt. 1.800\u20132.500 nm: <strong>JGS3 zwingend<\/strong>. \u00dcber 2.500 nm (mittleres IR \/ FT-IR): Quarz ganz verlassen, verwenden Sie <a href=\"https:\/\/machinedquartz.com\/de\/calciumfluorid-caf2-fenster-ftir-mittel-ir\/\">CaF\u2082<\/a> oder Saphir.<\/p>\n\n<h3>Schritt 2: Schichtdicke nach Wassergehalt w\u00e4hlen<\/h3>\n<p>W\u00e4ssrige Proben im NIR: 1\u20132 mm Schichtdicke ist Standard. Trockene Pulver \/ Folien \/ Gas: 10\u201350 mm. Verwenden Sie die <a href=\"https:\/\/machinedquartz.com\/de\/kuevetten-schichtdicke-nach-analyt\/\">Schichtdicke-nach-Analyt-Matrix<\/a> f\u00fcr spezifische Konzentrationsf\u00e4lle.<\/p>\n\n<h3>Schritt 3: Fertigung nach L\u00f6sungsmittel + Temperatur w\u00e4hlen<\/h3>\n<p>Nur w\u00e4ssrig bei Raumtemperatur: Standard 80 (g\u00fcnstigste). Gemischte organische L\u00f6sungsmittel bis 600 \u00b0C: <strong>Sintered 80 \/ Sintered 83<\/strong>. Pharma-QC mit Anforderung T > 83 % Transmission und Dampfautoklavierung: <strong>Molded 83<\/strong>. Siehe <a href=\"https:\/\/machinedquartz.com\/de\/herstellungsverfahren-quarzkuevetten\/\">Fertigungsmethoden<\/a>.<\/p>\n\n<h3>Schritt 4: Halterma\u00dfe best\u00e4tigen<\/h3>\n<p>Viele NIR-Analysatoren (besonders Foss\/Buchi\/Bruker) nutzen propriet\u00e4re K\u00fcvettenformate: messen Sie Ihren K\u00fcvettenhalter vor der Bestellung oder senden Sie das Ger\u00e4temodell, und wir gleichen die Kompatibilit\u00e4t ab.<\/p>\n<\/div>\n\n<!-- CTA -->\n<div class=\"cq-cta\">\n  <h3>Brauchen Sie JGS3 in einer Sondergr\u00f6\u00dfe?<\/h3>\n  <p>MachinedQuartz fertigt NIR-Sonderk\u00fcvetten nach Zeichnung in 4\u20136 Wochen, MOQ 1. Geben Sie die JGS3-Qualit\u00e4t in der Angebotsanfrage an.<\/p>\n  <a class=\"cq-btn\" href=\"https:\/\/machinedquartz.com\/contact\/\">Sonderangebot anfragen<\/a>\n  <a class=\"cq-btn cq-btn-2\" href=\"https:\/\/machinedquartz.com\/product-category\/products\/cuvettes\/infrared-ir-cuvettes\/\">Lager-SKUs ansehen<\/a>\n<\/div>\n\n<!-- FAQ -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">FAQ<\/div>\n<h2>H\u00e4ufig gestellte Fragen<\/h2>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Was ist der Unterschied zwischen einer NIR-K\u00fcvette und einer UV-Vis-K\u00fcvette?<\/div>\n  <div class=\"cq-faq-a\"><p>Der K\u00fcvettenk\u00f6rper selbst kann identisch sein; der entscheidende Unterschied ist die Quarzqualit\u00e4t. UV-Vis-K\u00fcvetten verwenden JGS1 (Tief-UV) oder JGS2 (Standard-UV-Vis); NIR-K\u00fcvetten verwenden JGS3, das < 5 ppm OH-Gehalt hat und bis 3.500 nm transparent bleibt. JGS1\/JGS2-K\u00fcvetten zeigen einen starken Absorptionseinbruch um 2.200 nm, der NIR-Messungen \u00fcber 1.800 nm verf\u00e4lscht.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Kann ich eine normale Quarzk\u00fcvette f\u00fcr NIR verwenden, wenn ich nur unter 1.500 nm arbeite?<\/div>\n  <div class=\"cq-faq-a\"><p>Ja, JGS2-K\u00fcvetten sind im kurzwelligen NIR (700\u20131.500 nm) brauchbar, wo die OH-Absorption noch nicht dominiert. \u00dcber 1.800 nm wird JGS3 zwingend. Das Risiko bei JGS1\/JGS2 selbst bei 1.000\u20131.500 nm ist Basislinien-Drift mit der Zeit, da die Luftfeuchte den Probenraum beeinflusst; zudem l\u00e4sst sich eine Kalibrierung sp\u00e4ter nicht auf l\u00e4ngere Wellenl\u00e4ngen \u00fcbertragen. F\u00fcr neue Methodenentwicklung standardm\u00e4\u00dfig JGS3 w\u00e4hlen.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Warum verwenden die meisten NIR-Methoden Schichtdicken von 1 mm oder k\u00fcrzer?<\/div>\n  <div class=\"cq-faq-a\"><p>Wasser absorbiert \u00fcber das gesamte NIR stark: bei 1.940 nm ist eine 10-mm-Wasserk\u00fcvette vollst\u00e4ndig undurchsichtig (A > 10 AU). Selbst bei 1.440 nm (der erste OH-Oberton) liest eine 10-mm-K\u00fcvette ~3,2 AU, weit \u00fcber dem linearen Bereich. Eine Verk\u00fcrzung auf 1 mm bringt diese Banden in den optimalen Bereich von 0,3\u20131,0 AU. Trockenproben (Pulver, Folien, Gas) haben diese Einschr\u00e4nkung nicht und nutzen routinem\u00e4\u00dfig 10\u201350-mm-K\u00fcvetten.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Ist JGS3 f\u00fcr Handheld-NIR-Analysatoren wie MicroNIR n\u00f6tig?<\/div>\n  <div class=\"cq-faq-a\"><p>Der JDSU MicroNIR deckt 950\u20131.650 nm ab, also innerhalb des f\u00fcr JGS2 akzeptablen Bereichs. F\u00fcr reine Handheld-Arbeit in diesem Band funktionieren JGS2-K\u00fcvetten. Umfasst Ihr Arbeitsablauf sowohl Handheld-Scans als auch den Labor-Kalibrierungstransfer auf Ger\u00e4te mit l\u00e4ngeren Wellenl\u00e4ngen (Buchi NIRFlex, Bruker MPA), verwenden Sie durchg\u00e4ngig JGS3, um spektrales \u00dcbersprechen zu vermeiden.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Brauche ich eine 4-Wege-Lichtk\u00fcvette f\u00fcr NIR?<\/div>\n  <div class=\"cq-faq-a\"><p>F\u00fcr reine Transmissions-NIR (das ist die meiste NIR-Arbeit: Foss, Buchi, Bruker, MicroNIR) gen\u00fcgt 2-Wege. 4-Wege ist n\u00f6tig, wenn Ihr Ger\u00e4t auch 90\u00b0-R\u00fcckstreuung oder Fluoreszenz erfasst (manche Prozessanalysatoren, biomedizinische Forschungsaufbauten). Geben Sie 4-Wege an, falls die M\u00f6glichkeit besteht, dass Sie sp\u00e4ter Streumessungen hinzuf\u00fcgen; der Aufpreis ist gering und Sie vermeiden den Neukauf.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Wie unterscheidet sich die NIR-Reinigung von der UV-Vis-K\u00fcvettenreinigung?<\/div>\n  <div class=\"cq-faq-a\"><p>Die NIR-spezifische Sorge ist Restwasser: selbst ein d\u00fcnner Wasserfilm auf der Innenfl\u00e4che tr\u00e4gt bei 1.440 und 1.940 nm erhebliche Absorption bei. Nach der Standard-L\u00f6sungsmittelreinigung mit wasserfreiem Methanol oder Ethanol verdr\u00e4ngen, dann mit N\u2082 trocknen. Mit einem Basislinienscan bei 1.940 nm verifizieren: sehen Sie durch eine leere K\u00fcvette einen Peak \u00fcber 0,05 AU, ist es Restwasser. Siehe das vollst\u00e4ndige <a href=\"https:\/\/machinedquartz.com\/de\/kuevetten-reinigungsprotokoll\/\">K\u00fcvetten-Reinigungsprotokoll<\/a>.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Was ist der Unterschied zwischen NIR und kurzwelligem IR (SWIR)?<\/div>\n  <div class=\"cq-faq-a\"><p>Die Begriffe \u00fcberlappen sich. NIR ist grob 700\u20132.500 nm. \u201eSWIR\u201c meint meist 1.000\u20132.500 nm und ist der Begriff aus der Fernerkundung und der hyperspektralen Bildgebung. \u00dcber 2.500 nm liegt das mittlere IR (MIR oder einfach \u201eIR\u201c), das CaF\u2082, Saphir oder KBr braucht; Quarz wird um 3.500 nm undurchsichtig. F\u00fcr den Grenzfall 2.500\u20133.500 nm funktioniert JGS3 noch.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Wie lang ist die Lieferzeit f\u00fcr eine JGS3-Sonderk\u00fcvette?<\/div>\n  <div class=\"cq-faq-a\"><p>Lagernde NIR-geeignete K\u00fcvetten (JGS1\/JGS2) versenden taggleich aus unserem US-Lager (5\u20138 Tage bis ins Labor). JGS3-Versionen werden auf Bestellung gefertigt: 4\u20136 Wochen f\u00fcr Schichtdicken bis 20 mm, 6\u20138 Wochen f\u00fcr 50 mm oder gr\u00f6\u00dfer. MOQ 1, keine Mindestbestellmenge f\u00fcr JGS3-Sonderanfertigungen.<\/p><\/div>\n<\/div>\n\n<\/div>\n\n<!-- BOTTOM CTA -->\n<div class=\"cq-cta\" style=\"margin-top: 50px;\">\n  <h3>Senden Sie uns Ihr NIR-Analysatormodell<\/h3>\n  <p>Wir gleichen die K\u00fcvettenhalter-Ma\u00dfe ab und empfehlen die JGS3-Schichtdicke anhand Ihres Wellenl\u00e4ngenbereichs; typische Antwort innerhalb von 24 Stunden.<\/p>\n  <a class=\"cq-btn\" href=\"https:\/\/machinedquartz.com\/contact\/\">Vertrieb per E-Mail<\/a>\n  <a class=\"cq-btn cq-btn-2\" href=\"https:\/\/machinedquartz.com\/de\/kuevetten-auswahlhilfe\/\">Auswahlhilfe lesen<\/a>\n<\/div>\n\n<\/div>\n\n<script>\ndocument.querySelectorAll('.cq-faq-q').forEach(function(q) {\n  q.addEventListener('click', function() {\n    var item = this.closest('.cq-faq-item');\n    var isOpen = item.classList.contains('open');\n    document.querySelectorAll('.cq-faq-item').forEach(function(i){ i.classList.remove('open'); });\n    if (!isOpen) item.classList.add('open');\n  });\n});\n<\/script>\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"Article\", \"headline\": \"NIR-Quarzk\u00fcvetten f\u00fcr die Spektroskopie von 700\u20132.500 nm\", \"description\": \"Quarzk\u00fcvetten der JGS3-Qualit\u00e4t f\u00fcr die Nahinfrarot-Spektroskopie: Getreidefeuchte, pharmazeutische Rohstoff-ID, Polymerfolien, biomedizinische NIR. Leitfaden zu Wellenl\u00e4nge \u00d7 Schichtdicke \u00d7 Material mit \u00fcber 8 Lager-SKUs.\", \"datePublished\": \"2026-05-11\", \"dateModified\": \"2026-05-11\", \"author\": {\"@type\": \"Organization\", \"name\": \"MachinedQuartz\"}, \"publisher\": {\"@type\": \"Organization\", \"name\": \"MachinedQuartz\", \"url\": \"https:\/\/machinedquartz.com\"}, \"mainEntityOfPage\": \"https:\/\/machinedquartz.com\/nir-cuvette-jgs3-quartz-spectroscopy\/\", \"about\": [{\"@type\": \"Thing\", \"name\": \"Near-infrared spectroscopy\"}, {\"@type\": \"Thing\", \"name\": \"JGS3 quartz\"}, {\"@type\": \"Thing\", \"name\": \"Quartz cuvette\"}], \"inLanguage\": \"de\"}<\/script>\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Was ist der Unterschied zwischen einer NIR-K\u00fcvette und einer UV-Vis-K\u00fcvette?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The cuvette body can be identical: the critical difference is quartz grade. UV-Vis uses JGS1 (deep UV) or JGS2; NIR uses JGS3 with <5 ppm OH content, transparent through 3,500 nm. JGS1\/JGS2 show absorption dip at 2,200 nm contaminating NIR above 1,800 nm.\"}}, {\"@type\": \"Question\", \"name\": \"Kann ich eine normale Quarzk\u00fcvette f\u00fcr NIR verwenden, wenn ich nur unter 1.500 nm arbeite?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, JGS2 cells work in short-wave NIR (700\u20131,500 nm). Above 1,800 nm, JGS3 mandatory. For new methods, default to JGS3 to enable longer-wavelength calibration transfer.\"}}, {\"@type\": \"Question\", \"name\": \"Warum verwenden die meisten NIR-Methoden Schichtdicken von 1 mm oder k\u00fcrzer?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Water absorbs strongly in NIR: at 1,940 nm a 10 mm aqueous cell is opaque (A>10). Even at 1,440 nm a 10 mm cell reads ~3.2 AU, above linear range. Shortening to 1 mm puts these bands in the 0.3\u20131.0 AU sweet spot.\"}}, {\"@type\": \"Question\", \"name\": \"Ist JGS3 f\u00fcr Handheld-NIR-Analysatoren wie MicroNIR n\u00f6tig?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"MicroNIR covers 950\u20131,650 nm: within JGS2-acceptable range. For pure handheld work, JGS2 works. If workflow includes calibration transfer to longer-wavelength instruments, use JGS3 throughout.\"}}, {\"@type\": \"Question\", \"name\": \"Brauche ich eine 4-Wege-Lichtk\u00fcvette f\u00fcr NIR?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"For pure transmission NIR (most NIR work), 2-way is sufficient. 4-way is needed for 90\u00b0 backscatter or fluorescence collection. Specify 4-way if there's any chance you'll add scattering measurements later.\"}}, {\"@type\": \"Question\", \"name\": \"Wie unterscheidet sich die NIR-Reinigung von der UV-Vis-K\u00fcvettenreinigung?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"NIR-specific concern is residual water: a thin film contributes significant absorbance at 1,440 and 1,940 nm. After standard cleaning, finish with anhydrous methanol displacement, dry with N\u2082, verify with baseline scan at 1,940 nm.\"}}, {\"@type\": \"Question\", \"name\": \"Was ist der Unterschied zwischen NIR und kurzwelligem IR (SWIR)?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"NIR is loosely 700\u20132,500 nm. SWIR usually means 1,000\u20132,500 nm in remote-sensing\/hyperspectral. Above 2,500 nm is mid-IR needing CaF\u2082, sapphire, or KBr. For 2,500\u20133,500 nm boundary, JGS3 still works.\"}}, {\"@type\": \"Question\", \"name\": \"Wie lang ist die Lieferzeit f\u00fcr eine JGS3-Sonderk\u00fcvette?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Stock NIR-suitable cells (JGS1\/JGS2) ship same day. JGS3 versions made-to-order: 4\u20136 weeks for path \u2264 20 mm, 6\u20138 weeks for 50 mm or larger. MOQ 1, no minimum.\"}}], \"inLanguage\": \"de\"}<\/script>\n\n\n","protected":false},"excerpt":{"rendered":"<p>NIR-Quarzk\u00fcvetten NIR-Quarzk\u00fcvetten f\u00fcr die Spektroskopie von 700\u20132.500 nm Quarzk\u00fcvetten der JGS3-Qualit\u00e4t, optimiert f\u00fcr das Nahinfrarot-Fenster: Getreidefeuchte-Analysatoren, pharmazeutische Rohstoffidentifizierung, Polymerfolien-QC und biomedizinische NIR. Wo Standard-JGS1 auf OH-Absorption trifft, bleibt JGS3 bis 3.500 nm transparent. 700\u20132.500 nm NIR-Fenster JGS3-Qualit\u00e4t OH-freies Quarzglas 0,5\u201350 mm Schichtdicke 2-Wege \/ 4-Wege Lichtgeometrie Eine NIR-Quarzk\u00fcvette ist eine K\u00fcvette f\u00fcr die Nahinfrarot-Spektroskopie aus<\/p>\n<div class=\"klb-readmore entry-button\"><a class=\"button\" href=\"https:\/\/machinedquartz.com\/de\/nir-quarzkuevetten-jgs3\/\">Read More<\/a><\/div>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1528,1527,1481],"tags":[],"class_list":["post-98491","post","type-post","status-publish","format-standard","hentry","category-alle-beitrage","category-quarz","category-unkategorisiert"],"_links":{"self":[{"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/posts\/98491","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/comments?post=98491"}],"version-history":[{"count":4,"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/posts\/98491\/revisions"}],"predecessor-version":[{"id":98591,"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/posts\/98491\/revisions\/98591"}],"wp:attachment":[{"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/media?parent=98491"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/categories?post=98491"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/machinedquartz.com\/de\/wp-json\/wp\/v2\/tags?post=98491"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}