{"id":98900,"date":"2026-05-21T10:00:00","date_gmt":"2026-05-21T02:00:00","guid":{"rendered":"https:\/\/machinedquartz.com\/guia-cubetas-cilindricas\/"},"modified":"2026-05-21T10:00:00","modified_gmt":"2026-05-21T02:00:00","slug":"guia-cubetas-cilindricas","status":"publish","type":"post","link":"https:\/\/machinedquartz.com\/es\/guia-cubetas-cilindricas\/","title":{"rendered":"Cubetas cil\u00edndricas para reflectancia difusa UV-Vis"},"content":{"rendered":"\n<div class=\"cq-aidef\" style=\"background:#fafbff;border:1px solid #e0e7ff;border-radius:10px;padding:18px 22px;margin:0 0 24px;\"><p style=\"margin:0;font-size:16px;line-height:1.65;color:#1e293b;\"><strong style=\"color:#1a2a6c;\">Una cubeta cil\u00edndrica es<\/strong> una cubeta de cuarzo de secci\u00f3n circular usada para mediciones de reflectancia difusa UV-Vis de polvos, suspensiones opacas y tejidos biol\u00f3gicos, donde una cubeta de cara plana causar\u00eda artefactos de reflexi\u00f3n especular. Los di\u00e1metros est\u00e1ndar son 22 mm y 28 mm; los pasos de luz son de 1\u201350 mm. Las cubetas cil\u00edndricas se emparejan con un accesorio de esfera integradora en instrumentos como el Cary 5000, el PerkinElmer Lambda 950 y el Shimadzu UV-3600.<\/p><\/div>\n\n\n\n<style>\n.csg-page { max-width:860px; margin:0 auto; padding:0 20px; }\n.csg-page p, .csg-page li { font-size:16px; line-height:1.7; color:#333; }\n.csg-page h2 { font-size:28px; font-weight:700; color:#1a2a6c; margin:48px 0 16px; line-height:1.3; padding-bottom:8px; border-bottom:2px solid #e8eaf0; }\n.csg-page h3 { font-size:21px; font-weight:700; color:#233a95; margin:32px 0 12px; line-height:1.35; }\n.csg-page h4 { font-size:17px; font-weight:700; color:#1a2a6c; margin:20px 0 8px; }\n.csg-page strong { color:#1a2a6c; }\n.csg-page a { color:#233a95; text-decoration:underline; text-underline-offset:2px; }\n.csg-page a:hover { color:#1a2a6c; }\n.csg-page table { width:100%; border-collapse:collapse; margin:20px 0; font-size:14px; }\n.csg-page table th, .csg-page table td { padding:10px 12px; border:1px solid #e8eaf0; text-align:left; vertical-align:top; }\n.csg-page table th { background:#f0f4fc; color:#1a2a6c; font-weight:700; font-size:13px; }\n.csg-page table tr:nth-child(even) td { background:#fafbfd; }\n\n.csg-hero { background:linear-gradient(135deg,#1a2a6c 0%,#233a95 60%,#1e4db7 100%) !important; border-radius:16px !important; padding:48px 36px !important; margin:24px 0 40px !important; color:#fff !important; }\n.csg-hero, .csg-hero p { background-color:transparent; color:#fff !important; }\n.csg-hero-eyebrow { font-size:12px !important; font-weight:700 !important; letter-spacing:2.4px !important; text-transform:uppercase !important; color:#a5c0ff !important; margin-bottom:12px !important; }\n.csg-hero-h1 { font-size:clamp(26px,3.6vw,38px) !important; font-weight:700 !important; line-height:1.2 !important; margin:0 0 14px !important; color:#fff !important; }\n.csg-hero-dek { font-size:16px !important; line-height:1.6 !important; color:#d0dcff !important; margin:0 0 24px !important; }\n.csg-hero-stats { display:grid; grid-template-columns:repeat(4,1fr); gap:0; background:rgba(255,255,255,0.08); border-radius:10px; }\n.csg-hero-stat { padding:14px 16px; border-right:1px solid rgba(255,255,255,0.12); }\n.csg-hero-stat:last-child { border-right:none; }\n.csg-hero-stat-num { font-size:18px; font-weight:700; color:#fff; }\n.csg-hero-stat-lbl { font-size:11px; color:#a5c0ff; text-transform:uppercase; letter-spacing:1.2px; margin-top:2px; }\n.csg-hero-cta { display:flex; gap:12px; margin-top:24px; flex-wrap:wrap; }\n.csg-hero-btn { display:inline-block; padding:12px 24px; border-radius:8px; font-weight:700; font-size:14px; text-decoration:none !important; transition:transform 0.15s, box-shadow 0.15s; }\n.csg-hero-btn-primary { background:#fff; color:#1a2a6c; }\n.csg-hero-btn-secondary { background:transparent !important; color:#fff !important; border:1.5px solid rgba(255,255,255,0.4) !important; }\n.csg-hero-btn:hover { transform:translateY(-2px); box-shadow:0 8px 20px rgba(0,0,0,0.18); }\n\n.csg-svg-figure { margin:28px 0; padding:16px; background:#fafbfd; border:1px solid #e8eaf0; border-radius:10px; }\n.csg-svg-figure svg { width:100%; height:auto; display:block; }\n.csg-svg-caption { font-size:13px; color:#555; margin-top:10px; line-height:1.55; }\n\n.csg-callout { background:#fffbf0; border-left:4px solid #f59e0b; padding:14px 18px; border-radius:6px; margin:20px 0; }\n.csg-callout-warn { background:#fef2f2; border-left-color:#dc2626; }\n.csg-callout-tip { background:#f0fdf4; border-left-color:#16a34a; }\n\n.csg-faq-item { border-bottom:1px solid #e8eaf0; }\n.csg-faq-q { display:flex; justify-content:space-between; align-items:center; padding:18px 0; cursor:pointer; font-weight:700; color:#1a2a6c; font-size:16px; }\n.csg-faq-q::after { content:\"+\"; font-size:24px; font-weight:300; color:#888; transition:transform 0.2s; }\n.csg-faq-item.open .csg-faq-q::after { content:\"\u2212\"; }\n.csg-faq-a { max-height:0; overflow:hidden; transition:max-height 0.3s ease; }\n.csg-faq-item.open .csg-faq-a { max-height:600px; padding-bottom:18px; }\n\n.csg-img-row { display:grid; grid-template-columns:repeat(3, 1fr); gap:16px; margin:24px 0 28px; }\n.csg-img-col { text-align:center; }\n.csg-img-col a { display:block; }\n.csg-img-col img { width:100%; border-radius:10px; box-shadow:0 4px 16px rgba(20,30,80,0.10); transition:transform 0.2s; }\n.csg-img-col a:hover img { transform:translateY(-3px); }\n.csg-img-caption { font-size:13px; color:#555; margin-top:10px; line-height:1.5; }\n.csg-img-caption strong { color:#1a2a6c; }\n@media (max-width:680px) { .csg-img-row { grid-template-columns:1fr; } .csg-hero-stats { grid-template-columns:repeat(2,1fr); } }\n\n.csg-eeat-box { background:#fff; border:1px solid #e8eaf0; border-left:4px solid #1a2a6c; border-radius:8px; padding:18px 22px; margin:32px 0; font-size:14px; color:#444; line-height:1.65; }\n.csg-eeat-box strong { color:#1a2a6c; }\n.csg-eeat-meta { font-size:12px; color:#888; margin-top:8px; }\n\n.csg-toc-floating { position:fixed; right:24px; top:140px; width:260px; background:#fff; border:1px solid #e8eaf0; border-radius:8px; padding:16px 18px; box-shadow:0 4px 16px rgba(20,30,80,0.06); font-size:13px; max-height:calc(100vh - 180px); overflow-y:auto; z-index:50; transition:transform 0.3s ease, right 0.3s ease, border-radius 0.3s ease, padding 0.3s ease, background 0.3s ease; }\n@media (max-width:1280px) { .csg-toc-floating { display:none; } }\n.csg-toc-floating > summary { cursor:pointer; list-style:none; user-select:none; outline:none; font-weight:700; color:#1a2a6c; font-size:11px; letter-spacing:1.5px; text-transform:uppercase; padding-bottom:8px; margin-bottom:8px; border-bottom:1px solid #e8eaf0; }\n.csg-toc-floating > summary::-webkit-details-marker { display:none; }\n.csg-toc-floating > summary::marker { content:\"\"; }\n.csg-toc-floating[open] > summary::after { content:\"\\25B6\"; float:right; font-size:11px; color:#888; line-height:1.4; margin-left:8px; }\n.csg-toc-floating[open] > ol { animation:csg-toc-slidein 0.25s ease-out; }\n@keyframes csg-toc-slidein { from { opacity:0; transform:translateX(16px); } to { opacity:1; transform:translateX(0); } }\n.csg-toc-floating ol { list-style:none !important; padding:0 !important; margin:0 !important; counter-reset:tocnum; }\n.csg-toc-floating ol li { list-style:none !important; }\n.csg-toc-floating li { position:relative !important; padding:6px 0 6px 28px !important; counter-increment:tocnum; margin:0 !important; }\n.csg-toc-floating li::before { content:counter(tocnum); position:absolute; left:0; top:6px; width:20px; height:20px; background:#f0f4fc; color:#233a95; border-radius:50%; font-size:11px; font-weight:700; display:flex; align-items:center; justify-content:center; }\n.csg-toc-floating li > a { color:#444; text-decoration:none; line-height:1.4; }\n.csg-toc-floating li > a:hover { color:#233a95; }\n.csg-toc-floating:not([open]) { right:0 !important; transform:translateX(calc(100% - 36px)); padding:0 !important; border-radius:8px 0 0 8px !important; max-height:none !important; overflow:visible !important; box-shadow:0 4px 16px rgba(20,30,80,0.10) !important; border-color:transparent !important; }\n.csg-toc-floating:not([open]) > summary { writing-mode:vertical-rl; transform:rotate(180deg); padding:20px 10px !important; margin:0 !important; border:none !important; background:linear-gradient(135deg,#1a2a6c 0%,#233a95 100%) !important; color:#fff !important; letter-spacing:1.8px; border-radius:0 8px 8px 0; min-height:140px; text-align:center; font-weight:700; }\n.csg-toc-floating:not([open]) > summary::after { content:\"\\25C0\"; float:none; display:block; margin-top:8px; color:rgba(255,255,255,0.85); transform:rotate(180deg); font-size:13px; }\n.csg-toc-floating:not([open]):hover { transform:translateX(calc(100% - 44px)); }\n.csg-toc-floating li.is-active::before { background:#233a95 !important; color:#fff !important; box-shadow:0 0 0 3px rgba(35,58,149,0.15); }\n.csg-toc-floating li.is-active > a { color:#1a2a6c !important; font-weight:700; }\n.csg-toc-floating li.is-active { background:linear-gradient(90deg, rgba(35,58,149,0.06) 0%, transparent 100%); border-radius:6px; }\n<\/style>\n\n<details class=\"csg-toc-floating\" open>\n<summary class=\"csg-toc-floating-title\">En esta p\u00e1gina<\/summary>\n<ol>\n<li><a href=\"#drs-vs-transmission\">DRS frente a transmisi\u00f3n<\/a><\/li>\n<li><a href=\"#anatomy\">Anatom\u00eda de la cubeta cil\u00edndrica<\/a><\/li>\n<li><a href=\"#applications\">Aplicaciones<\/a><\/li>\n<li><a href=\"#integrating-sphere\">Introducci\u00f3n a la esfera integradora<\/a><\/li>\n<li><a href=\"#outer-diameter\">Elegir el di\u00e1metro exterior<\/a><\/li>\n<li><a href=\"#interior-dims\">Dimensiones interiores<\/a><\/li>\n<li><a href=\"#sample-prep\">Preparaci\u00f3n de la muestra<\/a><\/li>\n<li><a href=\"#sintered-only\">Por qu\u00e9 solo Sintered 83<\/a><\/li>\n<li><a href=\"#cleaning\">Limpieza de cubetas cil\u00edndricas<\/a><\/li>\n<li><a href=\"#mq-products\">Productos recomendados<\/a><\/li>\n<li><a href=\"#faq\">Preguntas frecuentes<\/a><\/li>\n<\/ol>\n<\/details>\n\n<div class=\"csg-page\">\n<div class=\"csg-hero\">\n  <div class=\"csg-hero-eyebrow\">Reflectancia difusa \u00b7 Cubetas cil\u00edndricas UV-Vis<\/div>\n  <p class=\"csg-hero-h1\">Cubetas cil\u00edndricas para reflectancia difusa UV-Vis<\/p>\n\n  <p class=\"csg-hero-dek\">Polvos, lechadas, pel\u00edculas y s\u00f3lidos opacos \u2014 el tipo de cubeta que se usa en el puerto de entrada de una esfera integradora. Elija seg\u00fan la marca del espectr\u00f3metro, el volumen de muestra y el criterio de espesor infinito de Kubelka-Munk.<\/p>\n\n<div class=\"csg-hero-stats\">\n    <div class=\"csg-hero-stat\"><div class=\"csg-hero-stat-num\">\u03c612,5\u2013\u03c664 mm<\/div><div class=\"csg-hero-stat-lbl\">Rango de di\u00e1metro exterior<\/div><\/div>\n    <div class=\"csg-hero-stat\"><div class=\"csg-hero-stat-num\">M\u00e1s de 30 SKU<\/div><div class=\"csg-hero-stat-lbl\">En stock<\/div><\/div>\n    <div class=\"csg-hero-stat\"><div class=\"csg-hero-stat-num\">Sintered 83<\/div><div class=\"csg-hero-stat-lbl\">Fabricaci\u00f3n sin adhesivo<\/div><\/div>\n    <div class=\"csg-hero-stat\"><div class=\"csg-hero-stat-num\">5 marcas<\/div><div class=\"csg-hero-stat-lbl\">Compatibilidad con espectr\u00f3metros<\/div><\/div>\n  <\/div>\n  <div class=\"csg-hero-cta\">\n    <a href=\"https:\/\/machinedquartz.com\/product-category\/products\/cuvettes\/quartz-cylinder-cuvettes\/\" class=\"csg-hero-btn csg-hero-btn-primary\">Ver cubetas cil\u00edndricas<\/a>\n    <a href=\"https:\/\/machinedquartz.com\/contact\/\" class=\"csg-hero-btn csg-hero-btn-secondary\">Presupuesto de di\u00e1metro a medida<\/a>\n  <\/div>\n<\/div>\n\n<style>.mq-relbar{margin:24px 0 32px}.mq-relbar-title{font-size:11px;font-weight:700;letter-spacing:1.5px;color:#233a95;text-transform:uppercase;margin-bottom:14px}.mq-relbar-grid{display:grid;gap:10px}.mq-relbar-grid.cols-1{grid-template-columns:1fr}.mq-relbar-grid.cols-2{grid-template-columns:repeat(2,1fr)}.mq-relbar-grid.cols-3{grid-template-columns:repeat(3,1fr)}.mq-relbar-grid.cols-4{grid-template-columns:repeat(4,1fr)}.mq-relbar-grid.cols-5{grid-template-columns:repeat(5,1fr)}.mq-relbar-grid.cols-6{grid-template-columns:repeat(3,1fr)}.mq-relbar-grid.cols-7{grid-template-columns:repeat(4,1fr)}.mq-relbar-card{display:block;padding:12px 14px;background:#f7f8fc;border:1px solid #e8eaf0;border-radius:8px;text-decoration:none!important;transition:transform .15s,box-shadow .15s,border-color .15s}.mq-relbar-card:hover{transform:translateY(-2px);box-shadow:0 4px 14px rgba(26,42,108,.1);border-color:#1a73e8;background:#fff}.mq-relbar-card-emoji{font-size:18px;line-height:1;display:inline-block;margin-right:6px;vertical-align:middle}.mq-relbar-card-title{font-size:13px;font-weight:700;color:#1a2a6c!important;margin:0;line-height:1.3;display:inline-block;vertical-align:middle;text-decoration:none!important}.mq-relbar-card-sub{font-size:11px;color:#666!important;margin:3px 0 0;line-height:1.4;text-decoration:none!important}@media(max-width:1000px){.mq-relbar-grid.cols-5,.mq-relbar-grid.cols-6,.mq-relbar-grid.cols-7{grid-template-columns:repeat(3,1fr)}.mq-relbar-grid.cols-4{grid-template-columns:repeat(2,1fr)}}@media(max-width:600px){.mq-relbar-grid{grid-template-columns:repeat(2,1fr)!important}}@media(max-width:380px){.mq-relbar-grid{grid-template-columns:1fr!important}}<\/style>\n<div class=\"mq-relbar\"><div class=\"mq-relbar-title\">Gu\u00edas de cubetas relacionadas<\/div><div class=\"mq-relbar-grid cols-1\"><a class=\"mq-relbar-card\" href=\"https:\/\/machinedquartz.com\/demountable-cuvette-guide\/\"><span class=\"mq-relbar-card-emoji\">\ud83d\udd27<\/span><span class=\"mq-relbar-card-title\">Desmontable<\/span><p class=\"mq-relbar-card-sub\">cubetas de 0,5 \/ 1 \/ 2 mm<\/p><\/a><\/div><\/div>\n\n<div class=\"csg-eeat-box\">\n<strong>Revisado por el equipo t\u00e9cnico de MachinedQuartz.<\/strong> Fabricamos cubetas cil\u00edndricas de reflectancia para espectroscop\u00eda de reflectancia difusa UV-Vis desde 2026, con m\u00e1s de 30 SKU est\u00e1ndar en producci\u00f3n continua para clientes de I+D farmac\u00e9utica, caracterizaci\u00f3n de pol\u00edmeros, color\/cosm\u00e9tica y materiales de bater\u00edas. Los datos de compatibilidad con espectr\u00f3metros y los umbrales de profundidad de Kubelka-Munk de esta gu\u00eda provienen de mediciones de QC internas y de configuraciones de referencia de clientes.\n<div class=\"csg-eeat-meta\">Autor: equipo t\u00e9cnico de MachinedQuartz \u00b7 Publicado: 4 de mayo de 2026 \u00b7 \u00daltima revisi\u00f3n: 4 de mayo de 2026<\/div>\n<\/div>\n\n<h2 id=\"drs-vs-transmission\">Reflectancia difusa frente a transmisi\u00f3n \u2014 cu\u00e1ndo es correcta cada una<\/h2>\n<p>La espectroscop\u00eda UV-Vis se da en dos geometr\u00edas fundamentalmente distintas, y el tipo de cubeta lo determina cu\u00e1l de ellas requiere su muestra. Equivoque la geometr\u00eda y los datos no tienen ninguna posibilidad de ser significativos.<\/p>\n<figure class=\"csg-svg-figure\" id=\"fig1\">\n<svg viewBox=\"0 0 720 320\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" role=\"img\" aria-labelledby=\"svg1-title\">\n  <title id=\"svg1-title\">Comparaci\u00f3n de geometr\u00edas UV-Vis de transmisi\u00f3n frente a reflectancia difusa: en transmisi\u00f3n la luz atraviesa una muestra transparente; en reflectancia difusa una esfera integradora recoge la luz dispersada de un polvo o s\u00f3lido opaco<\/title>\n  <rect width=\"720\" height=\"320\" fill=\"#ffffff\"\/>\n  <text x=\"360\" y=\"26\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"15\" font-weight=\"700\" fill=\"#1a2a6c\">Transmisi\u00f3n frente a reflectancia difusa \u2014 dos geometr\u00edas \u00f3pticas distintas<\/text>\n\n  <!-- LEFT: Transmission -->\n  <g transform=\"translate(40, 60)\">\n    <text x=\"140\" y=\"0\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"13\" font-weight=\"700\" fill=\"#0ea5e9\">Transmisi\u00f3n (muestras transparentes)<\/text>\n\n    <!-- Source -->\n    <circle cx=\"20\" cy=\"120\" r=\"14\" fill=\"#7c3aed\"\/>\n    <text x=\"20\" y=\"125\" text-anchor=\"middle\" font-size=\"9\" font-weight=\"700\" fill=\"#fff\">L\u00e1mpara<\/text>\n\n    <!-- Cuvette (rectangular) -->\n    <rect x=\"100\" y=\"80\" width=\"80\" height=\"80\" fill=\"#dde7f7\" stroke=\"#1a2a6c\" stroke-width=\"2\"\/>\n    <text x=\"140\" y=\"125\" text-anchor=\"middle\" font-size=\"10\" fill=\"#1a2a6c\" font-weight=\"700\">Muestra transparente<\/text>\n\n    <!-- Light path straight through -->\n    <line x1=\"34\" y1=\"120\" x2=\"100\" y2=\"120\" stroke=\"#7c3aed\" stroke-width=\"3\" marker-end=\"url(#arrcyl1)\"\/>\n    <line x1=\"100\" y1=\"120\" x2=\"180\" y2=\"120\" stroke=\"#7c3aed\" stroke-width=\"3\" stroke-dasharray=\"3,2\" opacity=\"0.6\"\/>\n    <line x1=\"180\" y1=\"120\" x2=\"246\" y2=\"120\" stroke=\"#7c3aed\" stroke-width=\"3\" marker-end=\"url(#arrcyl1)\"\/>\n\n    <!-- Detector -->\n    <rect x=\"246\" y=\"106\" width=\"40\" height=\"28\" fill=\"#0ea5e9\" rx=\"3\"\/>\n    <text x=\"266\" y=\"124\" text-anchor=\"middle\" font-size=\"10\" font-weight=\"700\" fill=\"#fff\">Detector<\/text>\n\n    <text x=\"140\" y=\"200\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#0ea5e9\" font-weight=\"700\">El haz atraviesa la muestra<\/text>\n    <text x=\"140\" y=\"216\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"10\" fill=\"#444\">Lambert-Beer: A = \u03b5\u00b7c\u00b7l<\/text>\n    <text x=\"140\" y=\"232\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"10\" fill=\"#444\">Cubeta rectangular \u00b7 paso de 10 mm<\/text>\n  <\/g>\n\n  <!-- RIGHT: Diffuse reflectance -->\n  <g transform=\"translate(380, 60)\">\n    <text x=\"140\" y=\"0\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"13\" font-weight=\"700\" fill=\"#16a34a\">Reflectancia difusa (polvos, s\u00f3lidos)<\/text>\n\n    <!-- Integrating sphere (large circle) -->\n    <circle cx=\"140\" cy=\"120\" r=\"70\" fill=\"#fafbfd\" stroke=\"#1a2a6c\" stroke-width=\"2.5\"\/>\n    <text x=\"140\" y=\"80\" text-anchor=\"middle\" font-size=\"9\" fill=\"#888\">Esfera integradora<\/text>\n    <!-- Sphere texture -->\n    <circle cx=\"140\" cy=\"120\" r=\"55\" fill=\"none\" stroke=\"#888\" stroke-width=\"0.4\" stroke-dasharray=\"2,2\"\/>\n\n    <!-- Cylindrical cuvette at port (bottom of sphere) -->\n    <ellipse cx=\"140\" cy=\"195\" rx=\"22\" ry=\"7\" fill=\"#dde7f7\" stroke=\"#16a34a\" stroke-width=\"2\"\/>\n    <rect x=\"118\" y=\"180\" width=\"44\" height=\"20\" fill=\"#dde7f7\" stroke=\"#16a34a\" stroke-width=\"2\"\/>\n    <ellipse cx=\"140\" cy=\"180\" rx=\"22\" ry=\"7\" fill=\"#aac8ee\" stroke=\"#16a34a\" stroke-width=\"2\"\/>\n    <text x=\"140\" y=\"218\" text-anchor=\"middle\" font-size=\"10\" fill=\"#16a34a\" font-weight=\"700\">Cubeta cil\u00edndrica<\/text>\n    <text x=\"140\" y=\"232\" text-anchor=\"middle\" font-size=\"9\" fill=\"#444\">polvo\/s\u00f3lido opaco<\/text>\n\n    <!-- Source beam entering top -->\n    <circle cx=\"40\" cy=\"60\" r=\"12\" fill=\"#7c3aed\"\/>\n    <text x=\"40\" y=\"64\" text-anchor=\"middle\" font-size=\"9\" font-weight=\"700\" fill=\"#fff\">L\u00e1mpara<\/text>\n    <line x1=\"50\" y1=\"68\" x2=\"100\" y2=\"100\" stroke=\"#7c3aed\" stroke-width=\"2.5\" marker-end=\"url(#arrcyl1)\"\/>\n\n    <!-- Sample illuminated, light scatters -->\n    <line x1=\"140\" y1=\"180\" x2=\"80\" y2=\"100\" stroke=\"#fbbf24\" stroke-width=\"0.8\" opacity=\"0.6\"\/>\n    <line x1=\"140\" y1=\"180\" x2=\"200\" y2=\"100\" stroke=\"#fbbf24\" stroke-width=\"0.8\" opacity=\"0.6\"\/>\n    <line x1=\"140\" y1=\"180\" x2=\"100\" y2=\"60\" stroke=\"#fbbf24\" stroke-width=\"0.8\" opacity=\"0.6\"\/>\n    <line x1=\"140\" y1=\"180\" x2=\"180\" y2=\"60\" stroke=\"#fbbf24\" stroke-width=\"0.8\" opacity=\"0.6\"\/>\n\n    <!-- Detector at sphere port -->\n    <rect x=\"220\" y=\"155\" width=\"30\" height=\"20\" fill=\"#0ea5e9\" rx=\"3\"\/>\n    <text x=\"235\" y=\"170\" text-anchor=\"middle\" font-size=\"9\" font-weight=\"700\" fill=\"#fff\">Det.<\/text>\n    <line x1=\"195\" y1=\"160\" x2=\"218\" y2=\"160\" stroke=\"#0ea5e9\" stroke-width=\"0.6\" stroke-dasharray=\"2,2\"\/>\n  <\/g>\n\n  <defs>\n    <marker id=\"arrcyl1\" viewBox=\"0 0 10 10\" refX=\"9\" refY=\"5\" markerWidth=\"5\" markerHeight=\"5\" orient=\"auto\">\n      <path d=\"M 0 0 L 10 5 L 0 10 Z\" fill=\"#7c3aed\"\/>\n    <\/marker>\n  <\/defs>\n\n  <!-- Bottom takeaway -->\n  <rect x=\"40\" y=\"285\" width=\"640\" height=\"22\" fill=\"#f0f4fc\" stroke=\"#1a2a6c\" stroke-width=\"0.6\" rx=\"4\"\/>\n  <text x=\"360\" y=\"300\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#1a2a6c\">Transmisi\u00f3n para l\u00edquidos a trav\u00e9s de los que se ve \u00b7 reflectancia difusa para todo lo dem\u00e1s (polvo, pasta, pel\u00edcula, lechada, s\u00f3lido opaco)<\/text>\n<\/svg>\n<figcaption class=\"csg-svg-caption\"><strong>Figura 1.<\/strong> Las dos geometr\u00edas fundamentales de UV-Vis. La espectroscop\u00eda de transmisi\u00f3n hace pasar el haz a trav\u00e9s de una muestra transparente en una cubeta rectangular y detecta lo que sale por el otro lado; la absorbancia sigue la ley de Lambert-Beer. La reflectancia difusa ilumina una muestra opaca o dispersora en el puerto de entrada de una esfera integradora; la esfera recoge todos los fotones dispersados y el detector lee la intensidad reflejada total. Las cubetas cil\u00edndricas sostienen la muestra en el puerto de la esfera \u2014 son el contenedor de muestra est\u00e1ndar para cualquier medici\u00f3n UV-Vis de polvos, pel\u00edculas, lechadas o cualquier cosa a trav\u00e9s de la que no se pueda ver.<\/figcaption>\n<\/figure>\n<p><strong>La espectroscop\u00eda de transmisi\u00f3n<\/strong> hace pasar un haz colimado a trav\u00e9s de una muestra transparente y mide lo que llega al detector del otro lado. Se aplica la ley de Lambert-Beer: A = \u03b5\u00b7c\u00b7l. La muestra debe ser lo bastante transparente como para que algo de luz la atraviese. La cubeta es rectangular, el camino de la luz es fijo y se lee la concentraci\u00f3n directamente. Las cubetas est\u00e1ndar \u2014 la gu\u00eda de selecci\u00f3n, la gu\u00eda de paso de luz, todo el contenido habitual de cubetas \u2014 asumen transmisi\u00f3n.<\/p>\n<p><strong>La reflectancia difusa<\/strong> ilumina una muestra dispersora u opaca en el puerto de entrada de una esfera integradora. La esfera recoge todos los fotones que rebotan fuera de la muestra, sin importar la direcci\u00f3n; el detector lee la luz dispersada total. La muestra puede ser un polvo, una lechada, una pasta, una pel\u00edcula, una placa de pl\u00e1stico, una pel\u00edcula de pintura o cualquier s\u00f3lido. Las matem\u00e1ticas son distintas \u2014 teor\u00eda de Kubelka-Munk para concentraci\u00f3n absoluta, o simplemente ratios de transmisi\u00f3n relativa para trabajo de identificaci\u00f3n \u2014 pero la f\u00edsica es recuento de fotones a gran escala.<\/p>\n<p>Use reflectancia difusa cuando la muestra sea:<\/p>\n<ul>\n<li><strong>Un polvo<\/strong> \u2014 API farmac\u00e9uticos, ingredientes alimentarios, gr\u00e1nulos de pol\u00edmero, muestras de suelo, finos minerales<\/li>\n<li><strong>Un s\u00f3lido o losa opacos<\/strong> \u2014 comprimidos, pel\u00edculas pl\u00e1sticas, virutas de pintura, cer\u00e1mica, placas de vidrio con recubrimientos superficiales<\/li>\n<li><strong>Una suspensi\u00f3n dispersora<\/strong> \u2014 leche, lechada, emulsi\u00f3n, l\u00e1tex, muestras biol\u00f3gicas opacas<\/li>\n<li><strong>Una muestra muy pigmentada<\/strong> \u2014 incluso a concentraciones micromolares, la absorbancia satura una cubeta de transmisi\u00f3n<\/li>\n<\/ul>\n<p>Las cubetas cil\u00edndricas de reflectancia son el contenedor de muestra est\u00e1ndar para los cuatro casos. La cubeta se sit\u00faa en el puerto de entrada de la esfera integradora; la muestra se carga en la c\u00e1mara por arriba; la cara \u00f3ptica (la superior, en la mayor\u00eda de las configuraciones modernas) mira al interior de la esfera.<\/p>\n\n<h2 id=\"anatomy\">Anatom\u00eda de la cubeta cil\u00edndrica<\/h2>\n<p>Toda cubeta cil\u00edndrica de reflectancia se define por tres n\u00fameros: <strong>di\u00e1metro exterior<\/strong>, <strong>di\u00e1metro interior<\/strong>, y <strong>profundidad de muestra<\/strong>. El n\u00famero de pieza de MachinedQuartz los incluye los tres, en orden, separados por s\u00edmbolos \u00d7. Entender la convenci\u00f3n de numeraci\u00f3n es el primer paso para elegir la cubeta correcta.<\/p>\n<figure class=\"csg-svg-figure\" id=\"fig2\">\n<svg viewBox=\"0 0 720 340\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" role=\"img\" aria-labelledby=\"svg2-title\">\n  <title id=\"svg2-title\">Anatom\u00eda de la cubeta cil\u00edndrica de reflectancia que muestra di\u00e1metro exterior, cara \u00f3ptica, di\u00e1metro interior, profundidad de muestra y fondo o pared posterior \u2014 diagrama de secci\u00f3n etiquetado<\/title>\n  <rect width=\"720\" height=\"340\" fill=\"#ffffff\"\/>\n  <text x=\"360\" y=\"26\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"15\" font-weight=\"700\" fill=\"#1a2a6c\">Anatom\u00eda de la cubeta cil\u00edndrica \u2014 tres especificaciones definen el SKU<\/text>\n\n  <!-- Cross-section view of cylindrical cuvette -->\n  <g transform=\"translate(180, 70)\">\n    <!-- Outer body (cross section, vertical cut) -->\n    <rect x=\"0\" y=\"0\" width=\"180\" height=\"200\" fill=\"#fafbfd\" stroke=\"#1a2a6c\" stroke-width=\"2.5\"\/>\n    <!-- Top opening lip (small ring) -->\n    <line x1=\"-6\" y1=\"0\" x2=\"0\" y2=\"0\" stroke=\"#1a2a6c\" stroke-width=\"2.5\"\/>\n    <line x1=\"180\" y1=\"0\" x2=\"186\" y2=\"0\" stroke=\"#1a2a6c\" stroke-width=\"2.5\"\/>\n\n    <!-- Interior chamber (sample cavity, centered) -->\n    <rect x=\"40\" y=\"40\" width=\"100\" height=\"140\" fill=\"#aac8ee\" stroke=\"#1e4db7\" stroke-width=\"2\"\/>\n    <!-- Sample (powder) inside -->\n    <rect x=\"42\" y=\"60\" width=\"96\" height=\"118\" fill=\"url(#powderpat)\"\/>\n\n    <!-- Optical (front) face highlighted -->\n    <rect x=\"40\" y=\"40\" width=\"100\" height=\"2\" fill=\"#16a34a\"\/>\n    <text x=\"90\" y=\"34\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"10\" font-weight=\"700\" fill=\"#16a34a\">Cara \u00f3ptica (superior, pulida)<\/text>\n\n    <!-- Outer diameter dimension line -->\n    <line x1=\"-30\" y1=\"220\" x2=\"-30\" y2=\"0\" stroke=\"#888\" stroke-width=\"0.6\"\/>\n    <line x1=\"-35\" y1=\"0\" x2=\"-25\" y2=\"0\" stroke=\"#888\" stroke-width=\"0.6\"\/>\n    <line x1=\"-35\" y1=\"220\" x2=\"-25\" y2=\"220\" stroke=\"#888\" stroke-width=\"0.6\"\/>\n    <text x=\"-50\" y=\"115\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"11\" font-weight=\"700\" fill=\"#1a2a6c\" transform=\"rotate(-90, -50, 115)\">\u2300 exterior (p. ej., 50 mm)<\/text>\n\n    <!-- Interior diameter dimension -->\n    <line x1=\"40\" y1=\"240\" x2=\"140\" y2=\"240\" stroke=\"#1e4db7\" stroke-width=\"0.8\"\/>\n    <line x1=\"40\" y1=\"235\" x2=\"40\" y2=\"245\" stroke=\"#1e4db7\" stroke-width=\"0.8\"\/>\n    <line x1=\"140\" y1=\"235\" x2=\"140\" y2=\"245\" stroke=\"#1e4db7\" stroke-width=\"0.8\"\/>\n    <text x=\"90\" y=\"258\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"11\" font-weight=\"700\" fill=\"#1e4db7\">\u2300 interior (p. ej., 45 mm)<\/text>\n\n    <!-- Sample depth dimension -->\n    <line x1=\"160\" y1=\"40\" x2=\"160\" y2=\"180\" stroke=\"#dc2626\" stroke-width=\"0.8\"\/>\n    <line x1=\"155\" y1=\"40\" x2=\"165\" y2=\"40\" stroke=\"#dc2626\" stroke-width=\"0.8\"\/>\n    <line x1=\"155\" y1=\"180\" x2=\"165\" y2=\"180\" stroke=\"#dc2626\" stroke-width=\"0.8\"\/>\n    <text x=\"200\" y=\"115\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"11\" font-weight=\"700\" fill=\"#dc2626\" transform=\"rotate(-90, 200, 115)\">Profundidad (p. ej., 27,5 mm)<\/text>\n\n    <!-- Bottom note -->\n    <text x=\"90\" y=\"298\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"10\" fill=\"#888\">Fondo s\u00f3lido \u00b7 sella la muestra \u00b7 act\u00faa como interfaz dispersora para ensayos de transmisi\u00f3n<\/text>\n  <\/g>\n\n  <!-- SKU naming convention on right -->\n  <g transform=\"translate(440, 70)\">\n    <text x=\"0\" y=\"0\" font-family=\"Arial,sans-serif\" font-size=\"13\" font-weight=\"700\" fill=\"#1a2a6c\">Nomenclatura de SKU de MQ<\/text>\n    <line x1=\"0\" y1=\"6\" x2=\"240\" y2=\"6\" stroke=\"#1a2a6c\" stroke-width=\"0.8\"\/>\n\n    <text x=\"0\" y=\"34\" font-family=\"Arial,sans-serif\" font-size=\"12\" font-weight=\"700\" fill=\"#233a95\">Cubeta cil\u00edndrica de cuarzo \u03c650mm<\/text>\n    <text x=\"0\" y=\"50\" font-family=\"Arial,sans-serif\" font-size=\"12\" font-weight=\"700\" fill=\"#233a95\">de reflectancia,<\/text>\n    <text x=\"0\" y=\"66\" font-family=\"Arial,sans-serif\" font-size=\"12\" font-weight=\"700\" fill=\"#233a95\">Sintered 83,<\/text>\n    <text x=\"0\" y=\"82\" font-family=\"Arial,sans-serif\" font-size=\"12\" font-weight=\"700\" fill=\"#233a95\">interior \u03c645mm \u00d7 27,5mm<\/text>\n\n    <line x1=\"0\" y1=\"98\" x2=\"240\" y2=\"98\" stroke=\"#888\" stroke-width=\"0.4\"\/>\n\n    <text x=\"0\" y=\"120\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\"><tspan font-weight=\"700\" fill=\"#1a2a6c\">\u03c650mm<\/tspan> = di\u00e1metro exterior<\/text>\n    <text x=\"0\" y=\"138\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\"><tspan font-weight=\"700\" fill=\"#1e4db7\">\u03c645mm<\/tspan> = di\u00e1metro interior<\/text>\n    <text x=\"0\" y=\"156\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\"><tspan font-weight=\"700\" fill=\"#dc2626\">27,5mm<\/tspan> = profundidad de muestra<\/text>\n    <text x=\"0\" y=\"174\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\"><tspan font-weight=\"700\" fill=\"#1a2a6c\">Sintered 83<\/tspan> = construcci\u00f3n sin adhesivo<\/text>\n\n    <line x1=\"0\" y1=\"190\" x2=\"240\" y2=\"190\" stroke=\"#888\" stroke-width=\"0.4\"\/>\n\n    <text x=\"0\" y=\"214\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#1a2a6c\" font-weight=\"700\">Elija el SKU correcto por:<\/text>\n    <text x=\"0\" y=\"230\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">1. \u2300 exterior \u2192 puerto del espectr\u00f3metro<\/text>\n    <text x=\"0\" y=\"246\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">2. \u2300 interior \u00d7 profundidad \u2192 volumen de muestra<\/text>\n    <text x=\"0\" y=\"262\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">3. Profundidad \u2265 5 mm normalmente (Kubelka-Munk)<\/text>\n  <\/g>\n\n  <defs>\n    <pattern id=\"powderpat\" patternUnits=\"userSpaceOnUse\" width=\"6\" height=\"6\">\n      <rect width=\"6\" height=\"6\" fill=\"#dde7f7\"\/>\n      <circle cx=\"2\" cy=\"2\" r=\"0.7\" fill=\"#888\"\/>\n      <circle cx=\"4\" cy=\"4\" r=\"0.6\" fill=\"#888\"\/>\n    <\/pattern>\n  <\/defs>\n<\/svg>\n<figcaption class=\"csg-svg-caption\"><strong>Figura 2.<\/strong> Las tres especificaciones que definen cada SKU de cubeta cil\u00edndrica: di\u00e1metro exterior (coincide con el puerto de la esfera integradora de su espectr\u00f3metro), di\u00e1metro interior (volumen de muestra \u2014 normalmente 4\u20136 mm menor que el exterior) y profundidad (debe satisfacer el criterio de espesor infinito de Kubelka-Munk para reflectancia difusa, normalmente \u2265 5 mm para muestras moderadamente absorbentes). Los n\u00fameros de pieza de MQ siguen esta convenci\u00f3n exactamente: \u00abCil\u00edndrica \u03c650mm, interior \u03c645\u00d727,5mm\u00bb se lee como \u00abcuerpo exterior de 50 mm, c\u00e1mara de muestra de 45 mm de ancho \u00d7 27,5 mm de profundidad\u00bb.<\/figcaption>\n<\/figure>\n\n<p>Cada especificaci\u00f3n se asigna directamente a una decisi\u00f3n de compra:<\/p>\n<ul>\n<li><strong>El di\u00e1metro exterior<\/strong> debe coincidir con el puerto de la esfera integradora de su espectr\u00f3metro. La mayor\u00eda de los instrumentos modernos usan un puerto de 60 mm, pero los espectr\u00f3metros de sobremesa m\u00e1s peque\u00f1os y los instrumentos de gama alta con esferas a medida usan otros tama\u00f1os. Cubrimos la tabla de compatibilidad en la <a href=\"#outer-diameter\">Secci\u00f3n 5<\/a>.<\/li>\n<li><strong>El di\u00e1metro interior<\/strong> fija el volumen de muestra por unidad de profundidad. Mayor di\u00e1metro interior = m\u00e1s muestra = m\u00e1s promediado a lo largo del volumen de integraci\u00f3n. La mayor\u00eda de los laboratorios mantienen ~4 mm de espesor de pared (as\u00ed que una cubeta de 50 mm exterior tiene 42\u201346 mm interior).<\/li>\n<li><strong>La profundidad de muestra<\/strong> determina si la cubeta satisface el criterio de espesor infinito de Kubelka-Munk \u2014 la profundidad m\u00ednima a la que se puede aplicar la teor\u00eda DRS sin correcci\u00f3n por fuga por la parte posterior. Lo cubrimos en la <a href=\"#interior-dims\">Secci\u00f3n 6<\/a>.<\/li>\n<\/ul>\n\n<p>La cara \u00f3ptica es la superficie pulida que mira a la esfera integradora. En las cubetas modernas la cara \u00f3ptica es la parte superior del cilindro (la muestra se carga en la c\u00e1mara por arriba, la cara \u00f3ptica mira hacia arriba a la esfera). En algunos dise\u00f1os m\u00e1s antiguos la cara \u00f3ptica era el fondo \u2014 compruebe el portacubetas de su espectr\u00f3metro antes de pedir. Todas las cubetas de MachinedQuartz usan la orientaci\u00f3n est\u00e1ndar de cara \u00f3ptica superior.<\/p>\n\n<h2 id=\"applications\">D\u00f3nde se usan las cubetas cil\u00edndricas \u2014 seis clases de aplicaci\u00f3n<\/h2>\n<p>La reflectancia difusa UV-Vis cubre seis grandes clases de aplicaci\u00f3n, cada una con su tama\u00f1o de cubeta t\u00edpico y su rutina de preparaci\u00f3n de muestra:<\/p>\n\n<table>\n<thead><tr><th>Sector<\/th><th>Tipo de muestra<\/th><th>Longitud de onda<\/th><th>Tama\u00f1o de cubeta<\/th><th>Especificaci\u00f3n cr\u00edtica<\/th><\/tr><\/thead>\n<tbody>\n<tr><td><strong>I+D farmac\u00e9utica<\/strong><\/td><td>Polvos de API, comprimidos, intermedios<\/td><td>200\u2013800 nm<\/td><td>\u03c630\u2013\u03c650 mm<\/td><td>Identificaci\u00f3n de polimorfos, uniformidad de contenido, estado de hidrataci\u00f3n<\/td><\/tr>\n<tr><td><strong>Pol\u00edmeros y recubrimientos<\/strong><\/td><td>Pel\u00edculas, gr\u00e1nulos, masterbatch<\/td><td>250\u2013800 nm<\/td><td>\u03c630\u2013\u03c660 mm<\/td><td>Blancura, opacidad, dispersi\u00f3n de pigmentos<\/td><\/tr>\n<tr><td><strong>Color y cosm\u00e9tica<\/strong><\/td><td>Base de maquillaje, pintalabios, viruta de pintura<\/td><td>380\u2013700 nm<\/td><td>\u03c630\u2013\u03c660 mm<\/td><td>L*a*b*, brillo, opacidad<\/td><\/tr>\n<tr><td><strong>Investigaci\u00f3n de catalizadores<\/strong><\/td><td>Polvos, metales soportados<\/td><td>200\u20132500 nm<\/td><td>\u03c615\u2013\u03c630 mm<\/td><td>Estado de oxidaci\u00f3n, cin\u00e9tica in situ, cobertura cruzada UV-NIR<\/td><\/tr>\n<tr><td><strong>Bater\u00edas y electrodos<\/strong><\/td><td>Materiales de c\u00e1todo\/\u00e1nodo, estados litiados<\/td><td>300\u20132500 nm<\/td><td>\u03c615\u2013\u03c632 mm<\/td><td>Estado de carga, cin\u00e9tica de intercalaci\u00f3n, compatibilidad con caja de guantes<\/td><\/tr>\n<tr><td><strong>Alimentos y agricultura<\/strong><\/td><td>Cacao, queso, carne, granos, suelos<\/td><td>400\u20132500 nm<\/td><td>\u03c630\u2013\u03c660 mm<\/td><td>Color, humedad, grasa, m\u00e9tricas de reflectancia total<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<p>Dos notas de aplicaci\u00f3n especializadas que vale la pena se\u00f1alar:<\/p>\n<ul>\n<li><strong>PAT farmac\u00e9utico (tecnolog\u00eda anal\u00edtica de procesos)<\/strong>: DRS en l\u00ednea \/ en proceso para la fabricaci\u00f3n de comprimidos. A menudo usa zafiro o cubetas de sonda especializadas en lugar de cubetas discretas. Para el QC de laboratorio de lotes de polvo de API, las cubetas cil\u00edndricas de reflectancia son el formato de muestreo est\u00e1ndar.<\/li>\n<li><strong>DRS in situ de catalizadores<\/strong>: necesita una cubeta que pueda calentarse a 300\u2013400 \u00b0C mientras se ilumina. Las cubetas Standard 80 (con juntas de adhesivo) no pueden sobrevivir a esto; las cubetas Sintered 83 aguantan hasta 600 \u00b0C, las Molded 83 hasta 1200 \u00b0C. Para trabajo in situ, especifique fabricaci\u00f3n Molded 83.<\/li>\n<\/ul>\n\n<h2 id=\"integrating-sphere\">Esfera integradora \u2014 el accesorio que falta y que la mayor\u00eda de los laboratorios necesitan<\/h2>\n<p>Las cubetas cil\u00edndricas de reflectancia no funcionan solas. Son contenedores de muestra para el <strong>accesorio de esfera integradora<\/strong> del espectr\u00f3metro \u2014 un m\u00f3dulo \u00f3ptico independiente que debe instalarse en el compartimento de muestra antes de poder hacer cualquier medici\u00f3n DRS. Si su espectr\u00f3metro no ven\u00eda con una esfera integradora, tiene que comprar una como accesorio antes de que la cubeta sea \u00fatil.<\/p>\n<figure class=\"csg-svg-figure\" id=\"fig3\">\n<svg viewBox=\"0 0 720 320\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" role=\"img\" aria-labelledby=\"svg3-title\">\n  <title id=\"svg3-title\">Geometr\u00eda de la esfera integradora con un patr\u00f3n blanco de referencia en la pared de la esfera, el puerto de muestra en la parte inferior sosteniendo una cubeta cil\u00edndrica, la entrada del haz por arriba y el detector en un puerto lateral \u2014 disposici\u00f3n t\u00edpica del accesorio de un espectrofot\u00f3metro Cary 5000 o Lambda 1050<\/title>\n  <rect width=\"720\" height=\"320\" fill=\"#ffffff\"\/>\n  <text x=\"360\" y=\"26\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"15\" font-weight=\"700\" fill=\"#1a2a6c\">Esfera integradora \u2014 d\u00f3nde va la cubeta<\/text>\n\n  <!-- Sphere (large circle with internal coating texture) -->\n  <circle cx=\"360\" cy=\"170\" r=\"100\" fill=\"#fafbfd\" stroke=\"#1a2a6c\" stroke-width=\"3\"\/>\n  <circle cx=\"360\" cy=\"170\" r=\"92\" fill=\"none\" stroke=\"#aac8ee\" stroke-width=\"0.4\" stroke-dasharray=\"2,2\"\/>\n  <circle cx=\"360\" cy=\"170\" r=\"80\" fill=\"none\" stroke=\"#aac8ee\" stroke-width=\"0.3\" stroke-dasharray=\"1,2\"\/>\n\n  <!-- Sphere coating texture -->\n  <text x=\"360\" y=\"100\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"9\" fill=\"#888\">Spectralon \/ BaSO\u2084 coating \u00b7 > 98% blanco difuso<\/text>\n\n  <!-- Beam entrance port (top) -->\n  <line x1=\"360\" y1=\"60\" x2=\"360\" y2=\"78\" stroke=\"#1a2a6c\" stroke-width=\"3\"\/>\n  <ellipse cx=\"360\" cy=\"78\" rx=\"14\" ry=\"3\" fill=\"#fff\" stroke=\"#1a2a6c\" stroke-width=\"2\"\/>\n  <text x=\"360\" y=\"50\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"10\" font-weight=\"700\" fill=\"#7c3aed\">Entrada del haz<\/text>\n\n  <!-- Beam goes down to sample -->\n  <line x1=\"360\" y1=\"78\" x2=\"360\" y2=\"240\" stroke=\"#7c3aed\" stroke-width=\"2.5\" marker-end=\"url(#arrcyl3)\"\/>\n\n  <!-- Sample port (bottom) with cylindrical cuvette -->\n  <ellipse cx=\"360\" cy=\"240\" rx=\"20\" ry=\"4\" fill=\"#1a2a6c\" stroke=\"#1a2a6c\" stroke-width=\"2\"\/>\n  <rect x=\"340\" y=\"240\" width=\"40\" height=\"40\" fill=\"#dde7f7\" stroke=\"#16a34a\" stroke-width=\"2.5\"\/>\n  <ellipse cx=\"360\" cy=\"280\" rx=\"20\" ry=\"4\" fill=\"#dde7f7\" stroke=\"#16a34a\" stroke-width=\"2\"\/>\n  <!-- Powder pattern in cell -->\n  <rect x=\"343\" y=\"248\" width=\"34\" height=\"30\" fill=\"url(#powd2)\"\/>\n  <text x=\"360\" y=\"304\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#16a34a\" font-weight=\"700\">Cubeta cil\u00edndrica<\/text>\n\n  <!-- Reference white at far side (back wall of sphere) -->\n  <rect x=\"280\" y=\"155\" width=\"30\" height=\"30\" fill=\"#fff\" stroke=\"#888\" stroke-width=\"0.6\"\/>\n  <text x=\"295\" y=\"174\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"9\" fill=\"#888\">Blanco de<\/text>\n  <text x=\"295\" y=\"184\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"9\" fill=\"#888\">referencia<\/text>\n\n  <!-- Detector port (side) -->\n  <line x1=\"460\" y1=\"170\" x2=\"510\" y2=\"170\" stroke=\"#0ea5e9\" stroke-width=\"2\"\/>\n  <rect x=\"510\" y=\"155\" width=\"50\" height=\"30\" fill=\"#0ea5e9\" rx=\"3\"\/>\n  <text x=\"535\" y=\"174\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"10\" font-weight=\"700\" fill=\"#fff\">PMT<\/text>\n  <text x=\"535\" y=\"200\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"9\" fill=\"#0ea5e9\">puerto del detector<\/text>\n\n  <!-- Diffuse scatter from sample, photons bouncing in sphere -->\n  <line x1=\"360\" y1=\"240\" x2=\"280\" y2=\"170\" stroke=\"#fbbf24\" stroke-width=\"0.6\" opacity=\"0.5\"\/>\n  <line x1=\"360\" y1=\"240\" x2=\"450\" y2=\"170\" stroke=\"#fbbf24\" stroke-width=\"0.6\" opacity=\"0.5\"\/>\n  <line x1=\"360\" y1=\"240\" x2=\"280\" y2=\"200\" stroke=\"#fbbf24\" stroke-width=\"0.6\" opacity=\"0.5\"\/>\n  <line x1=\"360\" y1=\"240\" x2=\"450\" y2=\"200\" stroke=\"#fbbf24\" stroke-width=\"0.6\" opacity=\"0.5\"\/>\n  <line x1=\"280\" y1=\"170\" x2=\"360\" y2=\"160\" stroke=\"#fbbf24\" stroke-width=\"0.5\" opacity=\"0.4\"\/>\n  <line x1=\"450\" y1=\"170\" x2=\"370\" y2=\"160\" stroke=\"#fbbf24\" stroke-width=\"0.5\" opacity=\"0.4\"\/>\n\n  <!-- Side notes -->\n  <g transform=\"translate(40, 60)\">\n    <text x=\"0\" y=\"0\" font-family=\"Arial,sans-serif\" font-size=\"13\" font-weight=\"700\" fill=\"#1a2a6c\">C\u00f3mo funciona<\/text>\n    <text x=\"0\" y=\"20\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">1. El haz entra por el puerto superior<\/text>\n    <text x=\"0\" y=\"38\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">2. Incide en la muestra en el fondo<\/text>\n    <text x=\"0\" y=\"56\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">3. La muestra refleja de forma difusa<\/text>\n    <text x=\"0\" y=\"74\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">4. Las paredes de la esfera rebotan los fotones<\/text>\n    <text x=\"0\" y=\"92\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">5. El detector lee el estado estacionario<\/text>\n    <text x=\"0\" y=\"115\" font-family=\"Arial,sans-serif\" font-size=\"10\" fill=\"#888\">Esfera \u2265 50\u00d7 el volumen de muestra \u2192 todos los fotones recogidos sin importar la direcci\u00f3n de dispersi\u00f3n<\/text>\n  <\/g>\n\n  <g transform=\"translate(580, 60)\">\n    <text x=\"0\" y=\"0\" font-family=\"Arial,sans-serif\" font-size=\"13\" font-weight=\"700\" fill=\"#1a2a6c\">Tama\u00f1os de puerto comunes<\/text>\n    <text x=\"0\" y=\"20\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">\u230060 mm \u2014 el m\u00e1s moderno<\/text>\n    <text x=\"0\" y=\"38\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">\u230050 mm \u2014 Avantes, algunos<\/text>\n    <text x=\"0\" y=\"52\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">    espectr\u00f3metros de sobremesa<\/text>\n    <text x=\"0\" y=\"72\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">\u2300100\u2013150 mm \u2014 Lambda<\/text>\n    <text x=\"0\" y=\"86\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">    1050 \/ SolidSpec<\/text>\n    <text x=\"0\" y=\"106\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">\u230012,5\u201325 mm \u2014 sistemas<\/text>\n    <text x=\"0\" y=\"120\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#444\">    Ocean\/Avantes peque\u00f1os<\/text>\n  <\/g>\n\n  <defs>\n    <pattern id=\"powd2\" patternUnits=\"userSpaceOnUse\" width=\"4\" height=\"4\">\n      <rect width=\"4\" height=\"4\" fill=\"#dde7f7\"\/>\n      <circle cx=\"1.5\" cy=\"1.5\" r=\"0.6\" fill=\"#666\"\/>\n    <\/pattern>\n    <marker id=\"arrcyl3\" viewBox=\"0 0 10 10\" refX=\"9\" refY=\"5\" markerWidth=\"5\" markerHeight=\"5\" orient=\"auto\">\n      <path d=\"M 0 0 L 10 5 L 0 10 Z\" fill=\"#7c3aed\"\/>\n    <\/marker>\n  <\/defs>\n<\/svg>\n<figcaption class=\"csg-svg-caption\"><strong>Figura 3.<\/strong> Geometr\u00eda de la esfera integradora \u2014 el accesorio \u00f3ptico que define el trabajo de reflectancia difusa. El haz entra por el puerto superior, incide en la muestra en el puerto inferior (donde se sit\u00faa la cubeta cil\u00edndrica), se refleja de forma difusa en todas las direcciones, y el interior recubierto de blanco de la esfera rebota todos los fotones hasta que llegan al detector en un puerto lateral. El tama\u00f1o de la esfera debe ser al menos 50\u00d7 el volumen de muestra para una integraci\u00f3n precisa; los instrumentos de sobremesa comunes usan esferas de 60 mm para trabajo rutinario y esferas de 150 mm para sistemas UV-Vis-NIR premium.<\/figcaption>\n<\/figure>\n<p>An integrating sphere is exactly what it sounds like: a hollow sphere with a Spectralon\u2122 or BaSO\u2084 coating on the inside surface, a beam-entrance port on top, a sample port on the bottom, and a detector port on the side. The white coating reflects > el 98% de la luz incidente de forma difusa, as\u00ed que cualquier fot\u00f3n que rebote en la muestra acaba llegando al puerto del detector sin importar en qu\u00e9 direcci\u00f3n se dispers\u00f3. El detector lee la densidad de fotones en estado estacionario dentro de la esfera \u2014 proporcional a la reflectancia total de la muestra.<\/p>\n<p>Tres especificaciones de la esfera integradora determinan qu\u00e9 cubeta cil\u00edndrica necesita:<\/p>\n<ul>\n<li><strong>Di\u00e1metro de la esfera<\/strong> \u2014 normalmente 60 mm (la mayor\u00eda de los instrumentos modernos), 100 mm o 150 mm (UV-Vis-NIR premium), o 50 mm e inferiores (sistemas compactos de sobremesa y OEM). Las esferas m\u00e1s grandes recogen con m\u00e1s precisi\u00f3n pero son f\u00edsicamente mayores.<\/li>\n<li><strong>Di\u00e1metro del puerto de muestra<\/strong> \u2014 la abertura donde se sit\u00faa la cubeta. Esta es la especificaci\u00f3n que debe coincidir con el di\u00e1metro exterior de su cubeta; cubrimos la tabla en la <a href=\"#outer-diameter\">Secci\u00f3n 5<\/a>.<\/li>\n<li><strong>Recubrimiento de la esfera<\/strong> \u2014 Spectralon\u2122 (PTFE-based, > 99% de reflectancia, duradero) o BaSO\u2084 (m\u00e1s barato, menos estable al calor\/humedad). El recubrimiento no afecta a la especificaci\u00f3n de la cubeta, pero s\u00ed afecta a la calidad de los datos y a la vida \u00fatil.<\/li>\n<\/ul>\n<p>Para la mayor\u00eda de los laboratorios farmac\u00e9uticos, de pol\u00edmeros y de color, la esfera integradora la vende el fabricante del espectr\u00f3metro como accesorio: Cary 1500-001 (esfera de 60 mm para Cary 5000), PerkinElmer L2D-7600 (esfera de 150 mm para Lambda 1050), Shimadzu MPC-3100 (esfera de 60 mm para UV-3600). Las cubetas cil\u00edndricas de MachinedQuartz est\u00e1n dimensionadas para coincidir con estos puertos de accesorio est\u00e1ndar \u2014 v\u00e9ase la matriz de compatibilidad en la secci\u00f3n siguiente.<\/p>\n\n<h2 id=\"outer-diameter\">Elegir el di\u00e1metro exterior \u2014 haga coincidir el puerto de la esfera de su espectr\u00f3metro<\/h2>\n<p>La especificaci\u00f3n m\u00e1s importante para elegir una cubeta cil\u00edndrica es el di\u00e1metro exterior. Debe coincidir exactamente con el puerto de muestra de su accesorio de esfera integradora \u2014 dentro de \u00b1 0,2 mm. Una cubeta demasiado peque\u00f1a se cuela por el puerto; una demasiado grande bloquea el camino \u00f3ptico y produce se\u00f1al cero.<\/p>\n<figure class=\"csg-svg-figure\" id=\"fig4\">\n<svg viewBox=\"0 0 720 380\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" role=\"img\" aria-labelledby=\"svg4-title\">\n  <title id=\"svg4-title\">Matriz de compatibilidad del di\u00e1metro exterior de las cubetas cil\u00edndricas que asigna marcas de espectr\u00f3metro y accesorios de esfera integradora a los tama\u00f1os de cubeta requeridos \u2014 Cary 5000, PerkinElmer Lambda 950 y 1050, Shimadzu UV-3600, JASCO V-770, Hitachi U-4100, Avantes y Ocean Optics<\/title>\n  <rect width=\"720\" height=\"380\" fill=\"#ffffff\"\/>\n  <text x=\"360\" y=\"26\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"15\" font-weight=\"700\" fill=\"#1a2a6c\">Di\u00e1metro exterior \u00d7 espectr\u00f3metro \u2014 matriz de compatibilidad<\/text>\n  <text x=\"360\" y=\"44\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#666\">Haga coincidir el \u2300 exterior de la cubeta con el puerto de muestra de su esfera integradora<\/text>\n\n  <!-- Header row -->\n  <rect x=\"40\" y=\"60\" width=\"640\" height=\"36\" fill=\"#1a2a6c\"\/>\n  <text x=\"60\" y=\"83\" font-family=\"Arial,sans-serif\" font-size=\"12\" font-weight=\"700\" fill=\"#fff\">Modelo de espectr\u00f3metro<\/text>\n  <text x=\"380\" y=\"83\" font-family=\"Arial,sans-serif\" font-size=\"12\" font-weight=\"700\" fill=\"#fff\">Accesorio de esfera<\/text>\n  <text x=\"555\" y=\"83\" font-family=\"Arial,sans-serif\" font-size=\"12\" font-weight=\"700\" fill=\"#fff\">\u2300 de cubeta MQ<\/text>\n\n  <!-- Rows -->\n  <g font-family=\"Arial,sans-serif\" font-size=\"11\">\n    <rect x=\"40\" y=\"96\" width=\"640\" height=\"32\" fill=\"#fafbfd\"\/>\n    <text x=\"60\" y=\"116\" font-weight=\"700\" fill=\"#1a2a6c\">Agilent \/ Varian Cary 5000<\/text>\n    <text x=\"380\" y=\"116\" fill=\"#444\">Cary 1500-001 \u00b7 esfera de 60 mm<\/text>\n    <text x=\"555\" y=\"116\" font-weight=\"700\" fill=\"#16a34a\">\u03c660 mm<\/text>\n\n    <rect x=\"40\" y=\"128\" width=\"640\" height=\"32\" fill=\"#fff\"\/>\n    <text x=\"60\" y=\"148\" font-weight=\"700\" fill=\"#1a2a6c\">Agilent Cary 60 \/ 100 \/ 300<\/text>\n    <text x=\"380\" y=\"148\" fill=\"#444\">Kit de esfera externa de 60 mm<\/text>\n    <text x=\"555\" y=\"148\" font-weight=\"700\" fill=\"#16a34a\">\u03c660 mm<\/text>\n\n    <rect x=\"40\" y=\"160\" width=\"640\" height=\"32\" fill=\"#fafbfd\"\/>\n    <text x=\"60\" y=\"180\" font-weight=\"700\" fill=\"#1a2a6c\">PerkinElmer Lambda 950 \/ 1050<\/text>\n    <text x=\"380\" y=\"180\" fill=\"#444\">L2D-7600 \u00b7 esfera de 150 mm<\/text>\n    <text x=\"555\" y=\"180\" font-weight=\"700\" fill=\"#16a34a\">\u03c660 o \u03c664 mm<\/text>\n\n    <rect x=\"40\" y=\"192\" width=\"640\" height=\"32\" fill=\"#fff\"\/>\n    <text x=\"60\" y=\"212\" font-weight=\"700\" fill=\"#1a2a6c\">PerkinElmer Lambda 25 \/ 35 \/ 45<\/text>\n    <text x=\"380\" y=\"212\" fill=\"#444\">B0086712 \u00b7 esfera de 60 mm<\/text>\n    <text x=\"555\" y=\"212\" font-weight=\"700\" fill=\"#16a34a\">\u03c660 mm<\/text>\n\n    <rect x=\"40\" y=\"224\" width=\"640\" height=\"32\" fill=\"#fafbfd\"\/>\n    <text x=\"60\" y=\"244\" font-weight=\"700\" fill=\"#1a2a6c\">Shimadzu UV-3600 \/ SolidSpec<\/text>\n    <text x=\"380\" y=\"244\" fill=\"#444\">MPC-3100 \/ ISR-3100 \u00b7 60 mm<\/text>\n    <text x=\"555\" y=\"244\" font-weight=\"700\" fill=\"#16a34a\">\u03c660 mm<\/text>\n\n    <rect x=\"40\" y=\"256\" width=\"640\" height=\"32\" fill=\"#fff\"\/>\n    <text x=\"60\" y=\"276\" font-weight=\"700\" fill=\"#1a2a6c\">JASCO V-670 \/ V-770<\/text>\n    <text x=\"380\" y=\"276\" fill=\"#444\">PIV-756 \u00b7 esfera de 60 mm<\/text>\n    <text x=\"555\" y=\"276\" font-weight=\"700\" fill=\"#16a34a\">\u03c660 mm<\/text>\n\n    <rect x=\"40\" y=\"288\" width=\"640\" height=\"32\" fill=\"#fafbfd\"\/>\n    <text x=\"60\" y=\"308\" font-weight=\"700\" fill=\"#1a2a6c\">Hitachi U-4100 \/ U-3900<\/text>\n    <text x=\"380\" y=\"308\" fill=\"#444\">Esfera interna de 60 mm<\/text>\n    <text x=\"555\" y=\"308\" font-weight=\"700\" fill=\"#16a34a\">\u03c660 mm<\/text>\n\n    <rect x=\"40\" y=\"320\" width=\"640\" height=\"32\" fill=\"#fff\"\/>\n    <text x=\"60\" y=\"340\" font-weight=\"700\" fill=\"#1a2a6c\">Avantes AvaSphere \u00b7 sobremesa<\/text>\n    <text x=\"380\" y=\"340\" fill=\"#444\">AvaSphere-50 \/ AvaSphere-30<\/text>\n    <text x=\"555\" y=\"340\" font-weight=\"700\" fill=\"#16a34a\">\u03c650 \/ \u03c630 mm<\/text>\n  <\/g>\n\n  <line x1=\"370\" y1=\"60\" x2=\"370\" y2=\"352\" stroke=\"#e8eaf0\" stroke-width=\"0.6\"\/>\n  <line x1=\"540\" y1=\"60\" x2=\"540\" y2=\"352\" stroke=\"#e8eaf0\" stroke-width=\"0.6\"\/>\n<\/svg>\n<figcaption class=\"csg-svg-caption\"><strong>Figura 4.<\/strong> Matriz de compatibilidad espectr\u00f3metro-cubeta. El puerto de muestra de la esfera integradora determina el di\u00e1metro exterior de cubeta requerido \u2014 la mayor\u00eda de los instrumentos modernos usan puertos de 60 mm, pero ciertos sistemas compactos (serie Avantes AvaSphere) y los instrumentos de gama alta (PerkinElmer Lambda 1050 con accesorio de esfera de 150 mm) aceptan tama\u00f1os distintos. Si su instrumento no aparece aqu\u00ed, consulte la ficha t\u00e9cnica del accesorio de esfera integradora en \u00abdi\u00e1metro del puerto de muestra\u00bb o contacte con el departamento de accesorios del fabricante del espectr\u00f3metro; para tama\u00f1os no est\u00e1ndar MachinedQuartz puede presupuestar cubetas a medida con un plazo de 4 semanas.<\/figcaption>\n<\/figure>\n\n<p>La matriz de arriba cubre el 95% de los espectrofot\u00f3metros UV-Vis instalados. Tres observaciones de cotejarla con los pedidos de clientes:<\/p>\n\n<ul>\n<li><strong>60 mm es el est\u00e1ndar de facto.<\/strong> Si compra para un espectr\u00f3metro UV-Vis moderno gen\u00e9rico con esfera integradora, las cubetas cil\u00edndricas \u03c660 mm son la opci\u00f3n segura por defecto. MachinedQuartz mantiene en stock 8 SKU \u03c660 distintos con varias geometr\u00edas interiores.<\/li>\n<li><strong>El Lambda 1050 con la esfera de 150 mm admite \u03c660 o \u03c664.<\/strong> La esfera de 150 mm tiene un puerto reductor que admite cubetas de 60 mm con un espaciador, o cubetas de 64 mm sin \u00e9l. Tenemos ambas en stock.<\/li>\n<li><strong>Los sistemas OEM y a medida a menudo usan tama\u00f1os distintos de 60 mm.<\/strong> Los sistemas UV-Vis construidos a medida para PAT farmac\u00e9utico, sensores OEM y prototipos acad\u00e9micos usan di\u00e1metros m\u00e1s peque\u00f1os (\u03c612,5 a \u03c650 mm). Para estos fabricamos cubetas de di\u00e1metro a medida con un plazo de 4 semanas.<\/li>\n<\/ul>\n\n<p>Si su modelo de espectr\u00f3metro no est\u00e1 en la matriz:<\/p>\n<ol>\n<li>Abra la ficha t\u00e9cnica de su accesorio de esfera integradora<\/li>\n<li>Busque \u00abdi\u00e1metro del puerto de muestra\u00bb (normalmente en la secci\u00f3n de especificaciones \u00f3pticas)<\/li>\n<li>Haga coincidir con el di\u00e1metro exterior de la cubeta MQ \u2014 para tama\u00f1os no est\u00e1ndar, consulte el <a href=\"https:\/\/machinedquartz.com\/custom-quartz-cuvettes\/\">formulario de presupuesto de cubeta de cuarzo a medida<\/a><\/li>\n<\/ol>\n\n<h2 id=\"interior-dims\">Dimensiones interiores \u2014 profundidad, volumen y Kubelka-Munk<\/h2>\n<p>Una vez fijado el di\u00e1metro exterior a su espectr\u00f3metro, la segunda decisi\u00f3n es el tama\u00f1o de la c\u00e1mara interior. Dos especificaciones que fijar: <strong>di\u00e1metro interior<\/strong> (\u00e1rea de muestra presentada a la esfera) y <strong>profundidad de muestra<\/strong> (qu\u00e9 grosor tiene la columna de muestra en el camino \u00f3ptico).<\/p>\n\n<h3>El di\u00e1metro interior<\/h3>\n<p>El di\u00e1metro interior es el di\u00e1metro de la c\u00e1mara de muestra. La mayor\u00eda de las cubetas de MQ usan ~4\u20136 mm de espesor de pared, as\u00ed que una cubeta de \u03c650 mm exterior suele tener un interior de \u03c645 mm. Mayor interior = m\u00e1s \u00e1rea de muestra = m\u00e1s promediado = mejor representatividad para muestras heterog\u00e9neas (polvo mezclado, suelo, alimentos procesados). El compromiso es el volumen de muestra \u2014 una cubeta de \u03c645 \u00d7 27 mm contiene unos 43 mL de polvo, frente a 18 mL de una de \u03c645 \u00d7 11 mm.<\/p>\n\n<h3>Profundidad de muestra y el criterio de espesor infinito de Kubelka-Munk<\/h3>\n<p>La teor\u00eda de reflectancia difusa de Kubelka-Munk asume que la muestra es de \u00abespesor infinito\u00bb \u2014 es decir, que ninguna luz penetra del todo hasta la pared posterior y vuelve a salir. En la pr\u00e1ctica, el \u00abespesor infinito\u00bb se alcanza cuando la profundidad equivale a unas 3\u00d7 la profundidad de penetraci\u00f3n \u00f3ptica a su longitud de onda de medici\u00f3n.<\/p>\n<figure class=\"csg-svg-figure\" id=\"fig5\">\n<svg viewBox=\"0 0 720 320\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" role=\"img\" aria-labelledby=\"svg5-title\">\n  <title id=\"svg5-title\">Profundidad de muestra frente al criterio de espesor infinito de Kubelka-Munk que muestra la reflectancia estabiliz\u00e1ndose a medida que la profundidad aumenta m\u00e1s all\u00e1 de 5 mil\u00edmetros, con curvas separadas para muestras muy absorbentes que requieren menos profundidad y muestras poco absorbentes que necesitan m\u00e1s<\/title>\n  <rect width=\"720\" height=\"320\" fill=\"#ffffff\"\/>\n  <text x=\"360\" y=\"26\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"15\" font-weight=\"700\" fill=\"#1a2a6c\">Profundidad de muestra \u2014 \u00bfcu\u00e1ndo es \u00abinfinita\u00bb para Kubelka-Munk?<\/text>\n  <text x=\"360\" y=\"44\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"11\" fill=\"#666\">La reflectancia se estabiliza una vez que la profundidad supera la longitud de absorci\u00f3n<\/text>\n\n  <!-- Chart area: x 80-680, y 70-260 -->\n  <g>\n    <!-- Grid -->\n    <g stroke=\"#e8eaf0\" stroke-width=\"0.6\">\n      <line x1=\"80\" y1=\"120\" x2=\"680\" y2=\"120\"\/>\n      <line x1=\"80\" y1=\"170\" x2=\"680\" y2=\"170\"\/>\n      <line x1=\"80\" y1=\"220\" x2=\"680\" y2=\"220\"\/>\n      <line x1=\"200\" y1=\"70\" x2=\"200\" y2=\"260\"\/>\n      <line x1=\"320\" y1=\"70\" x2=\"320\" y2=\"260\"\/>\n      <line x1=\"440\" y1=\"70\" x2=\"440\" y2=\"260\"\/>\n      <line x1=\"560\" y1=\"70\" x2=\"560\" y2=\"260\"\/>\n    <\/g>\n\n    <!-- Strong absorber curve (saturates fast) -->\n    <path d=\"M 80 240 Q 130 150 170 110 Q 220 95 280 92 L 680 92\" stroke=\"#dc2626\" stroke-width=\"2.5\" fill=\"none\"\/>\n    <text x=\"280\" y=\"84\" font-family=\"Arial,sans-serif\" font-size=\"10\" font-weight=\"700\" fill=\"#dc2626\">Absorbente fuerte (polvo oscuro)<\/text>\n    <text x=\"280\" y=\"98\" font-family=\"Arial,sans-serif\" font-size=\"9\" fill=\"#dc2626\">infinito a ~3 mm<\/text>\n\n    <!-- Medium absorber -->\n    <path d=\"M 80 248 Q 160 200 240 150 Q 320 130 400 122 L 680 120\" stroke=\"#f59e0b\" stroke-width=\"2.5\" fill=\"none\"\/>\n    <text x=\"380\" y=\"142\" font-family=\"Arial,sans-serif\" font-size=\"10\" font-weight=\"700\" fill=\"#d97706\">Absorbente medio (API farmac\u00e9utico t\u00edpico)<\/text>\n    <text x=\"380\" y=\"156\" font-family=\"Arial,sans-serif\" font-size=\"9\" fill=\"#d97706\">infinito a ~5\u20138 mm<\/text>\n\n    <!-- Weak absorber (slow saturation) -->\n    <path d=\"M 80 252 Q 200 240 320 215 Q 440 195 560 175 L 680 162\" stroke=\"#0ea5e9\" stroke-width=\"2.5\" fill=\"none\"\/>\n    <text x=\"500\" y=\"195\" font-family=\"Arial,sans-serif\" font-size=\"10\" font-weight=\"700\" fill=\"#0ea5e9\">Absorbente d\u00e9bil (polvo blanco)<\/text>\n    <text x=\"500\" y=\"209\" font-family=\"Arial,sans-serif\" font-size=\"9\" fill=\"#0ea5e9\">infinito a ~15\u201325 mm<\/text>\n\n    <!-- 5 mm threshold marker -->\n    <line x1=\"200\" y1=\"70\" x2=\"200\" y2=\"260\" stroke=\"#16a34a\" stroke-width=\"1.5\" stroke-dasharray=\"4,3\"\/>\n    <text x=\"200\" y=\"62\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"10\" font-weight=\"700\" fill=\"#16a34a\">5 mm m\u00ednimo<\/text>\n\n    <!-- X axis -->\n    <line x1=\"80\" y1=\"260\" x2=\"680\" y2=\"260\" stroke=\"#333\" stroke-width=\"1.5\"\/>\n    <g font-family=\"Arial,sans-serif\" font-size=\"10\" fill=\"#555\">\n      <line x1=\"80\" y1=\"260\" x2=\"80\" y2=\"265\" stroke=\"#333\"\/>\n      <text x=\"80\" y=\"278\" text-anchor=\"middle\">0<\/text>\n      <line x1=\"200\" y1=\"260\" x2=\"200\" y2=\"265\" stroke=\"#333\"\/>\n      <text x=\"200\" y=\"278\" text-anchor=\"middle\">5<\/text>\n      <line x1=\"320\" y1=\"260\" x2=\"320\" y2=\"265\" stroke=\"#333\"\/>\n      <text x=\"320\" y=\"278\" text-anchor=\"middle\">10<\/text>\n      <line x1=\"440\" y1=\"260\" x2=\"440\" y2=\"265\" stroke=\"#333\"\/>\n      <text x=\"440\" y=\"278\" text-anchor=\"middle\">15<\/text>\n      <line x1=\"560\" y1=\"260\" x2=\"560\" y2=\"265\" stroke=\"#333\"\/>\n      <text x=\"560\" y=\"278\" text-anchor=\"middle\">20<\/text>\n      <line x1=\"680\" y1=\"260\" x2=\"680\" y2=\"265\" stroke=\"#333\"\/>\n      <text x=\"680\" y=\"278\" text-anchor=\"middle\">25<\/text>\n    <\/g>\n    <text x=\"380\" y=\"298\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"11\" font-weight=\"600\" fill=\"#333\">Profundidad de muestra (mm)<\/text>\n\n    <!-- Y axis -->\n    <line x1=\"80\" y1=\"70\" x2=\"80\" y2=\"260\" stroke=\"#333\" stroke-width=\"1.5\"\/>\n    <g font-family=\"Arial,sans-serif\" font-size=\"10\" fill=\"#555\">\n      <line x1=\"74\" y1=\"70\" x2=\"80\" y2=\"70\" stroke=\"#333\"\/>\n      <text x=\"70\" y=\"74\" text-anchor=\"end\">R\u221e<\/text>\n      <line x1=\"74\" y1=\"170\" x2=\"80\" y2=\"170\" stroke=\"#333\"\/>\n      <text x=\"70\" y=\"174\" text-anchor=\"end\">~0,5 R\u221e<\/text>\n      <line x1=\"74\" y1=\"260\" x2=\"80\" y2=\"260\" stroke=\"#333\"\/>\n      <text x=\"70\" y=\"264\" text-anchor=\"end\">0<\/text>\n    <\/g>\n    <text x=\"22\" y=\"170\" text-anchor=\"middle\" font-family=\"Arial,sans-serif\" font-size=\"11\" font-weight=\"600\" fill=\"#333\" transform=\"rotate(-90, 22, 170)\">Reflectancia R<\/text>\n  <\/g>\n<\/svg>\n<figcaption class=\"csg-svg-caption\"><strong>Figura 5.<\/strong> Why depth matters for Kubelka-Munk diffuse reflectance. The reflectance R approaches the \u201cinfinite-thickness\u201d value R\u221e as depth increases, but the rate depends on how strongly the sample absorbs at the wavelength being measured. Highly absorbing samples (dark powders, dye-loaded carriers) reach R\u221e within ~3 mm; weakly absorbing samples (white powders, lightly-pigmented films) need 15\u201325 mm. For the K-M math to work without correction, you need depth > 3\u00d7 la longitud de absorci\u00f3n aparente. La mayor\u00eda de las cubetas cil\u00edndricas de MachinedQuartz est\u00e1n dimensionadas con opciones de profundidad de 5\u201350 mm para cubrir todo el rango; elija la cubeta m\u00e1s profunda que la esfera de su espectr\u00f3metro pueda alojar.<\/figcaption>\n<\/figure>\n<p>Tres clases de muestra fijan requisitos de profundidad distintos:<\/p>\n\n<ul>\n<li><strong>Muestras muy absorbentes<\/strong> (polvos oscuros, muestras biol\u00f3gicas ricas en melanina, compuestos cargados de carbono): espesor infinito a 3 mm o menos. Sirve cualquier cubeta de profundidad est\u00e1ndar.<\/li>\n<li><strong>Absorbentes medios<\/strong> (API farmac\u00e9uticos t\u00edpicos, gr\u00e1nulos de pol\u00edmero, catalizadores inorg\u00e1nicos): infinito a 5\u20138 mm. Una cubeta de profundidad est\u00e1ndar de 8\u201311 mm suele ser segura.<\/li>\n<li><strong>Muestras poco absorbentes<\/strong> (polvos blancos, recubrimientos poco pigmentados, az\u00facares, formulaciones farmac\u00e9uticas a base de sacarosa): infinito a 15\u201325 mm. Necesitan una cubeta m\u00e1s profunda (\u03c640 \u00d7 19 mm o \u03c645 \u00d7 27,5 mm t\u00edpicas).<\/li>\n<\/ul>\n\n<p>Si no est\u00e1 seguro de d\u00f3nde se sit\u00faa su muestra en esta escala, la regla pr\u00e1ctica es: <strong>pida la cubeta m\u00e1s profunda que la esfera de su espectr\u00f3metro pueda admitir<\/strong>. El exceso de profundidad nunca perjudica la medici\u00f3n; una profundidad insuficiente causa una subestimaci\u00f3n sistem\u00e1tica de la absorbancia porque algunos fotones se fugan hacia la parte posterior de la cubeta y no se cuentan como reflejados.<\/p>\n\n<p>Para los c\u00e1lculos de volumen de muestra antes de pedir, use la <a href=\"https:\/\/machinedquartz.com\/cuvette-size-calculator\/\">calculadora de tama\u00f1o de cubeta<\/a> con la f\u00f3rmula de volumen cil\u00edndrico \u03c0r\u00b2h aplicada a las dimensiones interiores.<\/p>\n\n<h2 id=\"sample-prep\">Preparaci\u00f3n de la muestra \u2014 tama\u00f1o de part\u00edcula, densidad de empaquetado, superficie<\/h2>\n<p>Para la reflectancia difusa, la preparaci\u00f3n de la muestra importa m\u00e1s que para la espectroscop\u00eda de transmisi\u00f3n. Tres variables que los compradores de laboratorio subestiman sistem\u00e1ticamente:<\/p>\n\n<h3>Tama\u00f1o de part\u00edcula y molienda<\/h3>\n<p>La reflectancia var\u00eda sistem\u00e1ticamente con el tama\u00f1o de part\u00edcula: las part\u00edculas m\u00e1s peque\u00f1as dispersan m\u00e1s, aumentando la reflectancia aparente incluso a qu\u00edmica constante. Para obtener espectros comparables entre lotes, muela las muestras a un tama\u00f1o de part\u00edcula constante \u2014 normalmente < 100 \u00b5m for routine work, < 50 \u00b5m for trace measurement, < 10 \u00b5m for quantitative chemometrics. Use a mortar and pestle for small samples, a vibrating mill for harder materials, or a cryogenic grinder for thermosensitive samples.<\/p>\n<p>Si las muestras no se pueden moler (p. ej., comprimidos intactos, pel\u00edculas, gr\u00e1nulos grandes), est\u00e1 midiendo la superficie \u2014 no el grueso. El resultado sigue siendo \u00fatil para identificaci\u00f3n pero la cuantificaci\u00f3n requiere calibraci\u00f3n con muestras de referencia que tengan la misma textura superficial.<\/p>\n\n<h3>Densidad de empaquetado<\/h3>\n<p>El polvo suelto refleja un ~10\u201330% m\u00e1s que el polvo compactado del mismo material. Compacte siempre las muestras a la misma densidad: golpee suavemente la cubeta sobre la mesa, luego tape o cubra con una placa transparente para aplanar la superficie. Para el QC farmac\u00e9utico, documente el protocolo de empaquetado y s\u00edgalo de forma id\u00e9ntica en todas las muestras. Para la calibraci\u00f3n quimiom\u00e9trica, la variaci\u00f3n de empaquetado es la mayor fuente de error del modelo.<\/p>\n\n<h3>Planitud de la superficie<\/h3>\n<p>La cara \u00f3ptica de la cubeta est\u00e1 pulida plana. La muestra de dentro tambi\u00e9n deber\u00eda estar plana \u2014 la superficie expuesta deber\u00eda ser paralela a la cara \u00f3ptica. Una muestra apuntada o inclinada introduce retrodispersi\u00f3n dependiente del \u00e1ngulo que se interpreta como un desplazamiento de longitud de onda en el espectro de reflectancia. Aplane la parte superior de la columna de polvo con una esp\u00e1tula peque\u00f1a o una placa de fondo plano antes de cada medici\u00f3n.<\/p>\n\n<div class=\"csg-callout csg-callout-warn\"><strong>Atenci\u00f3n:<\/strong> No compacte las formulaciones farmac\u00e9uticas con demasiada fuerza \u2014 la sobrecompactaci\u00f3n cambia la porosidad y desplaza las bandas de reflectancia. El protocolo est\u00e1ndar es la compactaci\u00f3n \u00abautonivelante\u00bb: golpes suaves hasta que la superficie sea uniforme, sin presionar.<\/div>\n\n<h2 id=\"sintered-only\">Por qu\u00e9 la fabricaci\u00f3n Sintered 83 es la \u00fanica opci\u00f3n real para DRS<\/h2>\n<p>Las cubetas Standard 80 \u2014 la opci\u00f3n m\u00e1s barata del cat\u00e1logo est\u00e1ndar de MQ \u2014 usan adhesivo org\u00e1nico en las juntas. Para la espectroscop\u00eda de transmisi\u00f3n esto es invisible; para la reflectancia difusa produce un artefacto medible.<\/p>\n<p>La raz\u00f3n: la luz que rebota dentro de una esfera integradora recorre miles de caminos a trav\u00e9s de la muestra y las paredes de la cubeta antes de ser detectada. Cada camino que incide en una interfaz de adhesivo capta una peque\u00f1a emisi\u00f3n activa en el UV (el adhesivo fluoresce levemente bajo iluminaci\u00f3n UV). El efecto acumulado es una l\u00ednea base inclinada a 240\u2013340 nm que desplaza el espectro de reflectancia un 0,5\u20132% y cambia las posiciones aparentes de los picos en los modelos quimiom\u00e9tricos.<\/p>\n<p>Las cubetas Sintered 83 no tienen adhesivo en ninguna parte. El cuerpo de la cubeta se funde en polvo en una sola pieza bajo calor y presi\u00f3n; la luz solo rebota en interfaces de cuarzo puro. Por eso todas las cubetas cil\u00edndricas de reflectancia del cat\u00e1logo de MachinedQuartz son Sintered 83 \u2014 no hay opci\u00f3n Standard 80 en esta categor\u00eda, ni plan de a\u00f1adirla. Para el QC farmac\u00e9utico, la construcci\u00f3n trazable a efectos regulatorios y la medici\u00f3n de color de alta precisi\u00f3n, la Sintered 83 es la \u00fanica fabricaci\u00f3n que produce datos DRS limpios.<\/p>\n<p>Para trabajo DRS calentado in situ por encima de 300 \u00b0C, la fabricaci\u00f3n Molded 83 a\u00f1ade estabilidad t\u00e9rmica extra (tolerancia de 1200 \u00b0C) con un ligero sobreprecio. Ambas fabricaciones se detallan en el <a href=\"https:\/\/machinedquartz.com\/fabrication-method-of-cuvettes\/\">glosario del m\u00e9todo de fabricaci\u00f3n<\/a>.<\/p>\n\n<h2 id=\"cleaning\">Limpieza de cubetas cil\u00edndricas de reflectancia<\/h2>\n<p>Limpiar las cubetas DRS es m\u00e1s dif\u00edcil que limpiar las cubetas de transmisi\u00f3n por dos razones: el residuo de polvo se aloja en la c\u00e1mara cil\u00edndrica, y las trazas de muestras anteriores en la pared crean efectos de memoria espectral.<\/p>\n\n<p>Protocolo est\u00e1ndar para cubetas cil\u00edndricas:<\/p>\n<ol>\n<li><strong>Vac\u00ede la muestra<\/strong> \u2014 invierta la cubeta sobre un contenedor de residuos; golpee suavemente para desprender la mayor parte del polvo; cepille las part\u00edculas restantes con un cepillo suave de cerdas naturales (no sint\u00e9ticas; carga est\u00e1tica)<\/li>\n<li><strong>Primer enjuague con un solvente compatible con la muestra<\/strong> \u2014 agua DI para muestras solubles en agua, etanol para polvos org\u00e1nicos, hexano para compuestos hidr\u00f3fobos. No mezcle de golpe clases de solvente incompatibles.<\/li>\n<li><strong>Ba\u00f1o de Hellmanex a 50 \u00b0C durante 30 minutos<\/strong> \u2014 sumerja toda la cubeta; el residuo pegado se disuelve en el ba\u00f1o<\/li>\n<li><strong>Sonique a 40 kHz durante 5 minutos<\/strong> mientras est\u00e1 sumergida \u2014 nunca sonique en seco<\/li>\n<li><strong>5\u00d7 enjuague con agua DI<\/strong> \u2014 lave la c\u00e1mara a fondo; la geometr\u00eda cil\u00edndrica atrapa el residuo de detergente m\u00e1s que las cubetas rectangulares<\/li>\n<li><strong>Un \u00fanico enjuague con etanol<\/strong> para desplazar el agua<\/li>\n<li><strong>Seque al aire con la abertura hacia arriba toda la noche<\/strong> \u2014 nunca seque en horno por encima de 60 \u00b0C<\/li>\n<\/ol>\n\n<p>Para residuo farmac\u00e9utico envejecido o pegado (especialmente compuestos como la terbinafina, formulaciones cargadas de glucosa o muestras pigmentadas con melanina), el protocolo de limpieza profunda con \u00e1cido cr\u00f3mico es aceptable para las cubetas Sintered 83. Procedimiento completo en la <a href=\"https:\/\/machinedquartz.com\/cuvette-cleaning-protocol\/\">gu\u00eda del protocolo de limpieza de cubetas<\/a>.<\/p>\n\n<div class=\"csg-callout\"><strong>Consejo profesional:<\/strong> Para muestras coloreadas o pigmentadas que dejan manchas permanentes, haga una medici\u00f3n \u00aben blanco\u00bb en cada cubeta tras la limpieza para verificar que la l\u00ednea base ha vuelto a la referencia est\u00e1ndar. Un desplazamiento de reflectancia residual de 0,001\u20130,005 es normal y se puede restar; cualquier cosa mayor significa que la cubeta necesita una limpieza m\u00e1s profunda.<\/div>\n\n<h2 id=\"mq-products\">Cubetas cil\u00edndricas de MachinedQuartz recomendadas por espectr\u00f3metro<\/h2>\n<p>El cat\u00e1logo de cubetas cil\u00edndricas de reflectancia de MachinedQuartz cubre 13 di\u00e1metros exteriores de \u03c612,5 mm a \u03c664 mm, en m\u00e1s de 30 SKU en stock. Las configuraciones de abajo son las opciones m\u00e1s pedidas para las cuatro marcas de espectr\u00f3metro m\u00e1s comunes:<\/p>\n\n<h3>Para Cary 5000 \/ Cary 60-300 \/ Lambda 25-45 \/ UV-3600 \/ V-770 \/ Hitachi U-4100<\/h3>\n<p>Todos estos instrumentos usan un puerto de esfera de 60 mm y aceptan la misma familia de cubetas \u03c660 mm. Elija la profundidad interior seg\u00fan el tipo de muestra:<\/p>\n\n<div class=\"csg-img-row\">\n  <div class=\"csg-img-col\">\n    <a href=\"https:\/\/machinedquartz.com\/product\/quartz-50mm-cylindrical-reflectance-cuvette-sintered-83-c501ws1\/\">\n      <img decoding=\"async\" src=\"https:\/\/machinedquartz.com\/wp-content\/uploads\/2025\/07\/C501WS1-Cylindrical-Cuvette-For-Measuring-Reflected-Light-1pc-ea.jpg\" alt=\"Cubeta cil\u00edndrica de reflectancia \u03c650 mm C501WS1 de MachinedQuartz, cuarzo Sintered 83, para espectroscop\u00eda UV-Vis difusa\">\n    <\/a>\n    <p class=\"csg-img-caption\"><strong>\u03c650 mm \u00b7 C501WS1<\/strong><br>Para Avantes \/ esferas m\u00e1s peque\u00f1as<br><a href=\"https:\/\/machinedquartz.com\/product\/quartz-50mm-cylindrical-reflectance-cuvette-sintered-83-c501ws1\/\">Ver C501WS1 \u2192<\/a><\/p>\n  <\/div>\n  <div class=\"csg-img-col\">\n    <a href=\"https:\/\/machinedquartz.com\/product\/quartz-60mm-cylindrical-reflectance-cuvette-sintered-83-c601ws\/\">\n      <img decoding=\"async\" src=\"https:\/\/machinedquartz.com\/wp-content\/uploads\/2025\/07\/C601WS-Cylindrical-Cuvette-For-Measuring-Reflected-Light-1pc-ea.jpg\" alt=\"Cubeta cil\u00edndrica de reflectancia \u03c660 mm C601WS de MachinedQuartz, Sintered 83, para esfera integradora Cary 5000 Lambda Shimadzu\">\n    <\/a>\n    <p class=\"csg-img-caption\"><strong>\u03c660 mm \u00b7 C601WS \u2605<\/strong><br>Est\u00e1ndar Cary \/ Lambda \/ Shimadzu<br><a href=\"https:\/\/machinedquartz.com\/product\/quartz-60mm-cylindrical-reflectance-cuvette-sintered-83-c601ws\/\">Ver C601WS \u2192<\/a><\/p>\n  <\/div>\n  <div class=\"csg-img-col\">\n    <a href=\"https:\/\/machinedquartz.com\/product\/quartz-64mm-cylindrical-reflectance-cuvette-sintered-83-c641ws1\/\">\n      <img decoding=\"async\" src=\"https:\/\/machinedquartz.com\/wp-content\/uploads\/2025\/07\/C641WS1-Cylindrical-Cuvette-For-Measuring-Reflected-Light-1pc-ea.jpg\" alt=\"Cubeta cil\u00edndrica de reflectancia \u03c664 mm C641WS1 de MachinedQuartz, Sintered 83, para Lambda 1050 con esfera integradora de 150 mm\">\n    <\/a>\n    <p class=\"csg-img-caption\"><strong>\u03c664 mm \u00b7 C641WS1<\/strong><br>Lambda 1050 con esfera de 150 mm<br><a href=\"https:\/\/machinedquartz.com\/product\/quartz-64mm-cylindrical-reflectance-cuvette-sintered-83-c641ws1\/\">Ver C641WS1 \u2192<\/a><\/p>\n  <\/div>\n<\/div>\n\n<h3>Para PerkinElmer Lambda 950 \/ 1050 (esfera de 150 mm)<\/h3>\n<p>El Lambda 1050 con la esfera de 150 mm L2D-7600 acepta cubetas \u03c664 mm directamente, o cubetas \u03c660 mm con un puerto reductor. Tenemos ambas en stock:<\/p>\n\n<table>\n<thead><tr><th>Patr\u00f3n de SKU<\/th><th>\u2300 exterior<\/th><th>Interior<\/th><th>Mejor para<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>C641WS1 \/ C641WS<\/td><td>\u03c664 mm<\/td><td>\u03c660 \u00d7 36\u201350 mm<\/td><td>Ajuste nativo del Lambda 1050, muestras profundas<\/td><\/tr>\n<tr><td>C601WS<\/td><td>\u03c660 mm<\/td><td>\u03c655,2 \u00d7 27,6 mm<\/td><td>Lambda 1050 con puerto reductor<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<h3>Para esferas peque\u00f1as Avantes \/ Ocean Optics<\/h3>\n<p>Los espectr\u00f3metros compactos de sobremesa (serie Avantes AvaSpec \/ AvaSphere, Ocean Optics ISS \/ FOIS) usan puertos de esfera de 30\u201350 mm. Tenemos en stock las cubetas cil\u00edndricas a juego:<\/p>\n\n<table>\n<thead><tr><th>Modelo de esfera<\/th><th>\u2300 del puerto<\/th><th>Cubeta MQ<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>AvaSphere-50<\/td><td>50 mm<\/td><td>familia C501WS<\/td><\/tr>\n<tr><td>AvaSphere-30 \/ Ocean Optics ISS-30<\/td><td>30 mm<\/td><td>familia C301WS<\/td><\/tr>\n<tr><td>Avantes AvaSphere-15 \/ OEM compacto<\/td><td>12,5\u201317 mm<\/td><td>familia C12-51WS \/ C171WS<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<h3>Di\u00e1metros a medida y configuraciones especiales<\/h3>\n<p>Para di\u00e1metros fuera de los 13 tama\u00f1os est\u00e1ndar (p. ej., \u03c675 mm para PAT farmac\u00e9utico no est\u00e1ndar, \u03c68\u201310 mm para sensores \u00f3pticos OEM, cubetas encamisadas con control de temperatura, cubetas totalmente selladas para muestras sensibles a la humedad), MachinedQuartz presupuesta cubetas Sintered 83 a medida con un plazo de 4 semanas. Env\u00ede una solicitud a trav\u00e9s del <a href=\"https:\/\/machinedquartz.com\/custom-quartz-cuvettes\/\">formulario de cubetas de cuarzo a medida<\/a> con su modelo de espectr\u00f3metro y tipo de muestra.<\/p>\n\n<p>Para la lista completa de SKU con estado de stock, consulte el <a href=\"https:\/\/machinedquartz.com\/product-category\/products\/cuvettes\/quartz-cylinder-cuvettes\/\">cat\u00e1logo de cubetas cil\u00edndricas de cuarzo<\/a>. Para un an\u00e1lisis estilo paso de luz sobre la cuesti\u00f3n profundidad-frente-a-Kubelka-Munk, la <a href=\"https:\/\/machinedquartz.com\/path-length-calculator\/\">calculadora de paso de luz de Lambert-Beer<\/a> puede dar una estimaci\u00f3n inicial introduciendo la absorbancia aparente de su muestra a la longitud de onda objetivo.<\/p>\n\n<h2 id=\"faq\">Preguntas frecuentes<\/h2>\n<div class=\"csg-faq\">\n<div class=\"csg-faq-item\"><div class=\"csg-faq-q\">\u00bfPara qu\u00e9 se usa una cubeta cil\u00edndrica?<\/div><div class=\"csg-faq-a\"><p>Espectroscop\u00eda de reflectancia difusa UV-Vis de muestras opacas \u2014 polvos, lechadas, pel\u00edculas, placas de pl\u00e1stico y cualquier s\u00f3lido a trav\u00e9s del que no se pueda ver. La cubeta se sit\u00faa en el puerto de entrada de un accesorio de esfera integradora; la muestra se carga en la c\u00e1mara por arriba; la cara \u00f3ptica contacta con el interior de la esfera. Las cubetas cil\u00edndricas no se usan para espectroscop\u00eda de transmisi\u00f3n \u2014 para eso est\u00e1n las cubetas rectangulares.<\/p><\/div><\/div>\n<div class=\"csg-faq-item\"><div class=\"csg-faq-q\">\u00bfEn qu\u00e9 se diferencia la reflectancia difusa de la transmisi\u00f3n UV-Vis?<\/div><div class=\"csg-faq-a\"><p>La transmisi\u00f3n hace pasar el haz a trav\u00e9s de una muestra transparente y sigue la ley de Lambert-Beer (A = \u03b5\u00b7c\u00b7l). La reflectancia difusa ilumina una muestra opaca o dispersora y mide la intensidad reflejada total recogida por una esfera integradora. Las matem\u00e1ticas usan la teor\u00eda de Kubelka-Munk en lugar de Lambert-Beer. La geometr\u00eda de la cubeta difiere en consecuencia \u2014 rectangular para transmisi\u00f3n, cil\u00edndrica para reflectancia.<\/p><\/div><\/div>\n<div class=\"csg-faq-item\"><div class=\"csg-faq-q\">\u00bfNecesito una esfera integradora para usar una cubeta cil\u00edndrica?<\/div><div class=\"csg-faq-a\"><p>S\u00ed. Las cubetas cil\u00edndricas de reflectancia est\u00e1n dise\u00f1adas para encajar en el puerto de muestra de un accesorio de esfera integradora. Sin una esfera integradora, la cubeta no tiene una funci\u00f3n \u00f3ptica \u00fatil. Si su espectr\u00f3metro no ven\u00eda con una esfera integradora, tiene que comprar una como accesorio antes de que cualquier cubeta cil\u00edndrica sea \u00fatil \u2014 el coste t\u00edpico del accesorio es de 5000\u201325 000 $ seg\u00fan la marca del espectr\u00f3metro y el tama\u00f1o de la esfera.<\/p><\/div><\/div>\n<div class=\"csg-faq-item\"><div class=\"csg-faq-q\">\u00bfC\u00f3mo elijo el di\u00e1metro correcto de cubeta cil\u00edndrica para mi espectr\u00f3metro?<\/div><div class=\"csg-faq-a\"><p>Haga coincidir el di\u00e1metro exterior de la cubeta con el di\u00e1metro del puerto de muestra de su esfera integradora \u2014 la especificaci\u00f3n suele aparecer en el manual del accesorio de esfera integradora en \u00abdi\u00e1metro del puerto de muestra\u00bb. La mayor\u00eda de los instrumentos modernos usan puertos de 60 mm y necesitan una cubeta \u03c660 mm. Los sistemas premium de gama alta (Lambda 1050 con esfera de 150 mm) admiten \u03c664 mm. Los sistemas compactos (Avantes, Ocean Optics, OEM) usan di\u00e1metros m\u00e1s peque\u00f1os de \u03c612,5 a \u03c650 mm.<\/p><\/div><\/div>\n<div class=\"csg-faq-item\"><div class=\"csg-faq-q\">\u00bfQu\u00e9 profundidad debe tener la muestra en una cubeta cil\u00edndrica?<\/div><div class=\"csg-faq-a\"><p>La suficiente para satisfacer el criterio de espesor infinito de Kubelka-Munk a su longitud de onda de medici\u00f3n. Para muestras muy absorbentes (polvos oscuros, melanina), 3 mm bastan. Para API farmac\u00e9uticos y pol\u00edmeros t\u00edpicos, 5\u20138 mm. Para polvos blancos poco absorbentes y muestras poco pigmentadas, 15\u201325 mm. La regla segura es pedir la cubeta m\u00e1s profunda que su esfera admita y llenarla; el exceso de profundidad nunca perjudica.<\/p><\/div><\/div>\n<div class=\"csg-faq-item\"><div class=\"csg-faq-q\">\u00bfPor qu\u00e9 las cubetas cil\u00edndricas de MachinedQuartz solo se fabrican en Sintered 83?<\/div><div class=\"csg-faq-a\"><p>La reflectancia difusa implica miles de rebotes de luz dentro de la esfera integradora. Cada rebote que toca una interfaz de adhesivo (en las cubetas Standard 80) capta una emisi\u00f3n traza activa en el UV del adhesivo, produciendo un desplazamiento de l\u00ednea base del 0,5\u20132% en la regi\u00f3n de 240\u2013340 nm. Las cubetas Sintered 83 se funden en polvo en una sola pieza sin adhesivo en ninguna parte, eliminando este artefacto. Para el QC farmac\u00e9utico y la medici\u00f3n de color de alta precisi\u00f3n, la Sintered 83 es la \u00fanica fabricaci\u00f3n que produce datos DRS limpios.<\/p><\/div><\/div>\n<div class=\"csg-faq-item\"><div class=\"csg-faq-q\">\u00bfPuedo usar una cubeta cil\u00edndrica para muestras l\u00edquidas?<\/div><div class=\"csg-faq-a\"><p>S\u00ed, para l\u00edquidos opacos o dispersores \u2014 leche, l\u00e1tex, lechada, suspensi\u00f3n. La cubeta sostiene el l\u00edquido en la c\u00e1mara cil\u00edndrica y lo presenta a la esfera integradora. Para l\u00edquidos transparentes deber\u00eda usar una cubeta de transmisi\u00f3n rectangular \u2014 la reflectancia difusa sobre un l\u00edquido transparente no aporta nada \u00fatil porque la luz pasa hasta la pared posterior y rebota en \u00e1ngulos impredecibles.<\/p><\/div><\/div>\n<div class=\"csg-faq-item\"><div class=\"csg-faq-q\">\u00bfC\u00f3mo limpio una cubeta cil\u00edndrica de reflectancia?<\/div><div class=\"csg-faq-a\"><p>Vac\u00ede la muestra, enjuague primero con un solvente compatible con la muestra, luego sumerja toda la cubeta en Hellmanex al 1% a 50 \u00b0C durante 30 minutos, sonique a 40 kHz durante 5 minutos mientras est\u00e1 sumergida, triple enjuague con agua DI, enjuague de desplazamiento con etanol y luego seque al aire con la abertura hacia arriba toda la noche. La geometr\u00eda cil\u00edndrica atrapa m\u00e1s detergente que las cubetas rectangulares, as\u00ed que 5 enjuagues como m\u00ednimo. Procedimiento completo en la gu\u00eda del protocolo de limpieza.<\/p><\/div><\/div>\n<div class=\"csg-faq-item\"><div class=\"csg-faq-q\">\u00bfQu\u00e9 preparaci\u00f3n de muestra requiere la reflectancia difusa?<\/div><div class=\"csg-faq-a\"><p>Tres cosas importan m\u00e1s: el tama\u00f1o de part\u00edcula (moler a un tama\u00f1o constante < 100 \u00b5m for routine work, < 50 \u00b5m for chemometric calibration), packing density (gently tap to a uniform density across all samples \u2014 same protocol every time), and surface flatness (level the top of the powder column with a flat-bottom plate before measurement). Variation in these three is the largest source of systematic error in DRS calibration.<\/p><\/div><\/div>\n<div class=\"csg-faq-item\"><div class=\"csg-faq-q\">\u00bfD\u00f3nde encuentro cubetas cil\u00edndricas de di\u00e1metro a medida?<\/div><div class=\"csg-faq-a\"><p>MachinedQuartz presupuesta cubetas cil\u00edndricas Sintered 83 a medida en cualquier combinaci\u00f3n de di\u00e1metro exterior, di\u00e1metro interior y profundidad con un plazo de 4 semanas. Solicitudes a medida comunes: \u03c675 mm para sistemas PAT no est\u00e1ndar, \u03c68\u201310 mm para sensores \u00f3pticos OEM, cubetas encamisadas con control t\u00e9rmico para DRS in situ, cubetas selladas para muestras farmac\u00e9uticas sensibles a la humedad. Env\u00ede su modelo de espectr\u00f3metro y tipo de muestra a trav\u00e9s del formulario de presupuesto de cubetas de cuarzo a medida.<\/p><\/div><\/div>\n<\/div>\n\n<div class=\"csg-eeat-box\">\n<strong>Acerca de esta gu\u00eda.<\/strong> MachinedQuartz fabrica cubetas cil\u00edndricas de reflectancia para clientes de espectroscop\u00eda de reflectancia difusa UV-Vis en I+D farmac\u00e9utica, caracterizaci\u00f3n de pol\u00edmeros, color\/cosm\u00e9tica, investigaci\u00f3n de catalizadores y materiales de bater\u00edas. La compatibilidad con espectr\u00f3metros, los umbrales de profundidad de Kubelka-Munk y las pautas de preparaci\u00f3n de muestra provienen de mediciones de QC internas y de configuraciones de referencia de clientes en m\u00e1s de 30 SKU est\u00e1ndar.\n<div class=\"csg-eeat-meta\">Autor: equipo t\u00e9cnico de MachinedQuartz \u00b7 Publicado: 4 de mayo de 2026 \u00b7 \u00daltima revisi\u00f3n: 4 de mayo de 2026 \u00b7 Revisor: Bryan Wright (fundador, MQ).<\/div>\n<\/div>\n\n<h2 id=\"next-steps\">Siguiente paso: confirme el puerto de su esfera, elija la cubeta<\/h2>\n<p>Elegir la cubeta cil\u00edndrica de reflectancia correcta se reduce a tres n\u00fameros: di\u00e1metro exterior (debe coincidir con el puerto de esfera de su espectr\u00f3metro), dimensiones interiores (volumen de muestra \u00d7 profundidad para Kubelka-Munk) y fabricaci\u00f3n (Sintered 83 por defecto, Molded 83 para trabajo in situ a temperatura elevada).<\/p>\n<p>Para configuraciones no est\u00e1ndar o di\u00e1metros exteriores a medida, MachinedQuartz presupuesta cubetas a medida con un plazo de 4 semanas. Los SKU est\u00e1ndar se env\u00edan en 1\u20133 d\u00edas desde stock en EE. UU.<\/p>\n\n<p style=\"text-align:center; margin-top:32px;\">\n<a href=\"https:\/\/machinedquartz.com\/product-category\/products\/cuvettes\/quartz-cylinder-cuvettes\/\" class=\"csg-hero-btn csg-hero-btn-primary\" style=\"background:#1a2a6c; color:#fff; display:inline-block; padding:14px 28px; border-radius:8px; font-weight:700; font-size:14px; text-decoration:none; margin-right:8px;\">Ver cubetas cil\u00edndricas<\/a>\n<a href=\"https:\/\/machinedquartz.com\/contact\/\" class=\"csg-hero-btn\" style=\"background:transparent; color:#1a2a6c; border:1.5px solid #1a2a6c; display:inline-block; padding:13px 28px; border-radius:8px; font-weight:700; font-size:14px; text-decoration:none;\">Presupuesto de di\u00e1metro a medida<\/a>\n<\/p>\n<\/div>\n<script>\n(function(){\n  function initTocSpy(){\n    var tocLinks = document.querySelectorAll('.csg-toc-floating li > a[href^=\"#\"]');\n    if (tocLinks.length === 0) return;\n    var sections = [];\n    tocLinks.forEach(function(link){\n      var id = link.getAttribute('href').slice(1);\n      var el = document.getElementById(id);\n      if (el) sections.push({id: id, el: el, li: link.parentElement});\n    });\n    if (sections.length === 0) return;\n    function update(){\n      var scrollY = window.scrollY + 120;\n      var current = sections[0];\n      sections.forEach(function(s){ if (s.el.offsetTop <= scrollY) current = s; });\n      sections.forEach(function(s){ if (s === current) s.li.classList.add('is-active'); else s.li.classList.remove('is-active'); });\n    }\n    var ticking = false;\n    window.addEventListener('scroll', function(){\n      if (!ticking){ window.requestAnimationFrame(function(){ update(); ticking = false; }); ticking = true; }\n    }, {passive: true});\n    update();\n  }\n  function initFaq(){\n    document.querySelectorAll('.csg-faq-q').forEach(function(q) {\n      q.addEventListener('click', function() {\n        var item = this.closest('.csg-faq-item');\n        var isOpen = item.classList.contains('open');\n        document.querySelectorAll('.csg-faq-item').forEach(function(i){ i.classList.remove('open'); });\n        if (!isOpen) item.classList.add('open');\n      });\n    });\n  }\n  function init(){ initTocSpy(); initFaq(); }\n  if (document.readyState === 'loading') document.addEventListener('DOMContentLoaded', init);\n  else init();\n})();\n<\/script>\n\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"Article\", \"headline\": \"Gu\u00eda de cubetas cil\u00edndricas: reflectancia difusa UV-Vis\", \"description\": \"Cubetas cil\u00edndricas para reflectancia difusa UV-Vis de polvos, s\u00f3lidos y suspensiones: esfera integradora, di\u00e1metro, profundidad de Kubelka-Munk y por qu\u00e9 solo Sintered 83.\", \"datePublished\": \"2026-05-21\", \"dateModified\": \"2026-05-21\", \"inLanguage\": \"es\", \"author\": {\"@type\": \"Organization\", \"name\": \"MachinedQuartz Technical Team\"}, \"publisher\": {\"@type\": \"Organization\", \"name\": \"MachinedQuartz\", \"url\": \"https:\/\/machinedquartz.com\"}, \"mainEntityOfPage\": \"https:\/\/machinedquartz.com\/es\/guia-cubetas-cilindricas\/\"}<\/script>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"\u00bfPara qu\u00e9 se usa una cubeta cil\u00edndrica?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Espectroscop\u00eda de reflectancia difusa UV-Vis de muestras opacas \u2014 polvos, lechadas, pel\u00edculas, placas de pl\u00e1stico y cualquier s\u00f3lido a trav\u00e9s del que no se pueda ver. La cubeta se sit\u00faa en el puerto de entrada de un accesorio de esfera integradora; la muestra se carga en la c\u00e1mara por arriba; la cara \u00f3ptica contacta con el interior de la esfera. Las cubetas cil\u00edndricas no se usan para espectroscop\u00eda de transmisi\u00f3n \u2014 para eso est\u00e1n las cubetas rectangulares.\"}}, {\"@type\": \"Question\", \"name\": \"\u00bfEn qu\u00e9 se diferencia la reflectancia difusa de la transmisi\u00f3n UV-Vis?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"La transmisi\u00f3n hace pasar el haz a trav\u00e9s de una muestra transparente y sigue la ley de Lambert-Beer (A = \u03b5\u00b7c\u00b7l). La reflectancia difusa ilumina una muestra opaca o dispersora y mide la intensidad reflejada total recogida por una esfera integradora. Las matem\u00e1ticas usan la teor\u00eda de Kubelka-Munk en lugar de Lambert-Beer. La geometr\u00eda de la cubeta difiere en consecuencia \u2014 rectangular para transmisi\u00f3n, cil\u00edndrica para reflectancia.\"}}, {\"@type\": \"Question\", \"name\": \"\u00bfNecesito una esfera integradora para usar una cubeta cil\u00edndrica?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"S\u00ed. Las cubetas cil\u00edndricas de reflectancia est\u00e1n dise\u00f1adas para encajar en el puerto de muestra de un accesorio de esfera integradora. Sin una esfera integradora, la cubeta no tiene una funci\u00f3n \u00f3ptica \u00fatil. Si su espectr\u00f3metro no ven\u00eda con una esfera integradora, tiene que comprar una como accesorio antes de que cualquier cubeta cil\u00edndrica sea \u00fatil \u2014 el coste t\u00edpico del accesorio es de 5000\u201325 000 $ seg\u00fan la marca del espectr\u00f3metro y el tama\u00f1o de la esfera.\"}}, {\"@type\": \"Question\", \"name\": \"\u00bfC\u00f3mo elijo el di\u00e1metro correcto de cubeta cil\u00edndrica para mi espectr\u00f3metro?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Haga coincidir el di\u00e1metro exterior de la cubeta con el di\u00e1metro del puerto de muestra de su esfera integradora \u2014 la especificaci\u00f3n suele aparecer en el manual del accesorio de esfera integradora en \u00abdi\u00e1metro del puerto de muestra\u00bb. La mayor\u00eda de los instrumentos modernos usan puertos de 60 mm y necesitan una cubeta \u03c660 mm. Los sistemas premium de gama alta (Lambda 1050 con esfera de 150 mm) admiten \u03c664 mm. Los sistemas compactos (Avantes, Ocean Optics, OEM) usan di\u00e1metros m\u00e1s peque\u00f1os de \u03c612,5 a \u03c650 mm.\"}}, {\"@type\": \"Question\", \"name\": \"\u00bfQu\u00e9 profundidad debe tener la muestra en una cubeta cil\u00edndrica?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"La suficiente para satisfacer el criterio de espesor infinito de Kubelka-Munk a su longitud de onda de medici\u00f3n. Para muestras muy absorbentes (polvos oscuros, melanina), 3 mm bastan. Para API farmac\u00e9uticos y pol\u00edmeros t\u00edpicos, 5\u20138 mm. Para polvos blancos poco absorbentes y muestras poco pigmentadas, 15\u201325 mm. La regla segura es pedir la cubeta m\u00e1s profunda que su esfera admita y llenarla; el exceso de profundidad nunca perjudica.\"}}, {\"@type\": \"Question\", \"name\": \"\u00bfPor qu\u00e9 las cubetas cil\u00edndricas de MachinedQuartz solo se fabrican en Sintered 83?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"La reflectancia difusa implica miles de rebotes de luz dentro de la esfera integradora. Cada rebote que toca una interfaz de adhesivo (en las cubetas Standard 80) capta una emisi\u00f3n traza activa en el UV del adhesivo, produciendo un desplazamiento de l\u00ednea base del 0,5\u20132% en la regi\u00f3n de 240\u2013340 nm. Las cubetas Sintered 83 se funden en polvo en una sola pieza sin adhesivo en ninguna parte, eliminando este artefacto. Para el QC farmac\u00e9utico y la medici\u00f3n de color de alta precisi\u00f3n, la Sintered 83 es la \u00fanica fabricaci\u00f3n que produce datos DRS limpios.\"}}, {\"@type\": \"Question\", \"name\": \"\u00bfPuedo usar una cubeta cil\u00edndrica para muestras l\u00edquidas?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"S\u00ed, para l\u00edquidos opacos o dispersores \u2014 leche, l\u00e1tex, lechada, suspensi\u00f3n. La cubeta sostiene el l\u00edquido en la c\u00e1mara cil\u00edndrica y lo presenta a la esfera integradora. Para l\u00edquidos transparentes deber\u00eda usar una cubeta de transmisi\u00f3n rectangular \u2014 la reflectancia difusa sobre un l\u00edquido transparente no aporta nada \u00fatil porque la luz pasa hasta la pared posterior y rebota en \u00e1ngulos impredecibles.\"}}, {\"@type\": \"Question\", \"name\": \"\u00bfC\u00f3mo limpio una cubeta cil\u00edndrica de reflectancia?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Vac\u00ede la muestra, enjuague primero con un solvente compatible con la muestra, luego sumerja toda la cubeta en Hellmanex al 1% a 50 \u00b0C durante 30 minutos, sonique a 40 kHz durante 5 minutos mientras est\u00e1 sumergida, triple enjuague con agua DI, enjuague de desplazamiento con etanol y luego seque al aire con la abertura hacia arriba toda la noche. La geometr\u00eda cil\u00edndrica atrapa m\u00e1s detergente que las cubetas rectangulares, as\u00ed que 5 enjuagues como m\u00ednimo. Procedimiento completo en la gu\u00eda del protocolo de limpieza.\"}}, {\"@type\": \"Question\", \"name\": \"\u00bfQu\u00e9 preparaci\u00f3n de muestra requiere la reflectancia difusa?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Tres cosas importan m\u00e1s: el tama\u00f1o de part\u00edcula (muela a un tama\u00f1o constante para obtener espectros comparables entre lotes), la densidad de empaquetado (compacte siempre a la misma densidad; el polvo suelto refleja un 10\u201330% m\u00e1s que el compactado) y la planitud de la superficie (aplane la columna de muestra paralela a la cara \u00f3ptica para evitar retrodispersi\u00f3n dependiente del \u00e1ngulo).\"}}, {\"@type\": \"Question\", \"name\": \"\u00bfD\u00f3nde encuentro cubetas cil\u00edndricas de di\u00e1metro a medida?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"MachinedQuartz presupuesta cubetas cil\u00edndricas Sintered 83 a medida en cualquier combinaci\u00f3n de di\u00e1metro exterior, di\u00e1metro interior y profundidad con un plazo de 4 semanas. Solicitudes a medida comunes: \u03c675 mm para sistemas PAT no est\u00e1ndar, \u03c68\u201310 mm para sensores \u00f3pticos OEM, cubetas encamisadas con control t\u00e9rmico para DRS in situ, cubetas selladas para muestras farmac\u00e9uticas sensibles a la humedad. Env\u00ede su modelo de espectr\u00f3metro y tipo de muestra a trav\u00e9s del formulario de presupuesto de cubetas de cuarzo a medida.\"}}]}<\/script>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Inicio\", \"item\": \"https:\/\/machinedquartz.com\/es\/\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Gu\u00edas de cubetas\", \"item\": \"https:\/\/machinedquartz.com\/es\/guia-seleccion-cubetas\/\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"Gu\u00eda de cubetas cil\u00edndricas\", \"item\": \"https:\/\/machinedquartz.com\/es\/guia-cubetas-cilindricas\/\"}]}<\/script>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"HowTo\", \"name\": \"C\u00f3mo elegir una cubeta cil\u00edndrica de reflectancia\", \"description\": \"Proceso de cinco pasos para elegir la cubeta cil\u00edndrica de reflectancia correcta seg\u00fan el puerto de la esfera integradora, el di\u00e1metro, la profundidad y la fabricaci\u00f3n.\", \"totalTime\": \"PT4M\", \"inLanguage\": \"es\", \"step\": [{\"@type\": \"HowToStep\", \"position\": 1, \"name\": \"Confirme el tama\u00f1o del puerto de la esfera integradora del espectr\u00f3metro\", \"text\": \"Consulte el di\u00e1metro del puerto de muestra en el manual de su accesorio de esfera integradora. La mayor\u00eda de los instrumentos modernos usan 60 mm; los sistemas de gama alta pueden usar de 100 a 150 mm; los sistemas OEM compactos usan de 12,5 a 50 mm.\"}, {\"@type\": \"HowToStep\", \"position\": 2, \"name\": \"Elija el di\u00e1metro exterior\", \"text\": \"Haga coincidir el di\u00e1metro exterior de la cubeta con el puerto de la esfera dentro de \u00b1 0,2 mm. Para puertos de 60 mm use cubetas \u03c660; para el Lambda 1050 con esfera de 150 mm use cubetas \u03c664; para el Avantes AvaSphere 50 use cubetas \u03c650.\"}, {\"@type\": \"HowToStep\", \"position\": 3, \"name\": \"Determine la profundidad de muestra necesaria\", \"text\": \"Los absorbentes fuertes alcanzan el espesor infinito de Kubelka-Munk a 3 mm; los medios a 5\u20138 mm; los d\u00e9biles a 15\u201325 mm. Elija la cubeta m\u00e1s profunda que su esfera admita.\"}, {\"@type\": \"HowToStep\", \"position\": 4, \"name\": \"Fije el di\u00e1metro interior\", \"text\": \"Las cubetas est\u00e1ndar de MQ usan de 4 a 6 mm de espesor de pared, as\u00ed que el di\u00e1metro interior es de 4 a 12 mm menor que el exterior. Un di\u00e1metro interior mayor da mejor promediado para muestras heterog\u00e9neas.\"}, {\"@type\": \"HowToStep\", \"position\": 5, \"name\": \"Confirme que la fabricaci\u00f3n es Sintered 83\", \"text\": \"Todas las cubetas cil\u00edndricas de reflectancia de MachinedQuartz son Sintered 83 por defecto, sin adhesivo en el paso \u00f3ptico. Para DRS calentado in situ por encima de 300 grados Celsius, especifique Molded 83.\"}]}<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>Una cubeta cil\u00edndrica es una cubeta de cuarzo de secci\u00f3n circular usada para mediciones de reflectancia difusa UV-Vis de polvos, suspensiones opacas y tejidos biol\u00f3gicos, donde una cubeta de cara plana causar\u00eda artefactos de reflexi\u00f3n especular. Los di\u00e1metros est\u00e1ndar son 22 mm y 28 mm; los pasos de luz son de 1\u201350 mm. Las cubetas<\/p>\n<div class=\"klb-readmore entry-button\"><a class=\"button\" href=\"https:\/\/machinedquartz.com\/es\/guia-cubetas-cilindricas\/\">Read More<\/a><\/div>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1480],"tags":[],"class_list":["post-98900","post","type-post","status-publish","format-standard","hentry","category-sin-categorizar"],"_links":{"self":[{"href":"https:\/\/machinedquartz.com\/es\/wp-json\/wp\/v2\/posts\/98900","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/machinedquartz.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/machinedquartz.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/machinedquartz.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/machinedquartz.com\/es\/wp-json\/wp\/v2\/comments?post=98900"}],"version-history":[{"count":0,"href":"https:\/\/machinedquartz.com\/es\/wp-json\/wp\/v2\/posts\/98900\/revisions"}],"wp:attachment":[{"href":"https:\/\/machinedquartz.com\/es\/wp-json\/wp\/v2\/media?parent=98900"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/machinedquartz.com\/es\/wp-json\/wp\/v2\/categories?post=98900"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/machinedquartz.com\/es\/wp-json\/wp\/v2\/tags?post=98900"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}