{"id":98747,"date":"2026-06-12T08:40:32","date_gmt":"2026-06-12T00:40:32","guid":{"rendered":"https:\/\/machinedquartz.com\/cuves-circulation-quartz-hplc\/"},"modified":"2026-06-12T11:59:27","modified_gmt":"2026-06-12T03:59:27","slug":"cuves-circulation-quartz-hplc","status":"publish","type":"post","link":"https:\/\/machinedquartz.com\/fr\/cuves-circulation-quartz-hplc\/","title":{"rendered":"Cuves \u00e0 circulation en quartz pour l&rsquo;HPLC et l&rsquo;analyse en flux continu"},"content":{"rendered":"\n<style>\n.cq-page { max-width: 860px; margin: 0 auto; padding: 0 20px; font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", sans-serif; color: #1e293b; }\n.cq-page p, .cq-page li { font-size: 16px; line-height: 1.7; }\n.cq-section { margin-bottom: 56px; }\n.cq-section h2 { font-size: 26px; font-weight: 700; color: #1a2a6c; margin-bottom: 18px; line-height: 1.3; }\n.cq-section h3 { font-size: 19px; font-weight: 600; color: #233a95; margin: 24px 0 10px; }\n.cq-section-label { font-size: 11px; font-weight: 700; letter-spacing: 2px; text-transform: uppercase; color: #233a95; margin-bottom: 8px; }\n\n.cq-hero { background: linear-gradient(135deg, #0f4c81 0%, #1e6091 60%, #2980b9 100%); border-radius: 16px; padding: 50px 36px; text-align: center; color: #fff; margin-bottom: 48px; }\n.cq-hero-eyebrow { font-size: 12px; font-weight: 600; letter-spacing: 2px; text-transform: uppercase; color: #a8d0e6; margin-bottom: 14px; }\n.cq-hero-h1 { font-size: clamp(26px, 4vw, 40px); font-weight: 700; line-height: 1.2; margin: 0 0 16px; color: #fff; }\n.cq-hero p.cq-hero-sub { font-size: 16px; color: #d8eaf3; max-width: 640px; margin: 0 auto 28px; line-height: 1.6; }\n.cq-stats { display: grid; grid-template-columns: repeat(4, 1fr); gap: 0; background: rgba(255,255,255,0.08); border-radius: 10px; margin-top: 24px; }\n.cq-stat { padding: 16px 10px; border-right: 1px solid rgba(255,255,255,0.12); }\n.cq-stat:last-child { border-right: none; }\n.cq-stat-num { font-size: 20px; font-weight: 700; color: #fff; line-height: 1.1; }\n.cq-stat-label { font-size: 10px; color: #a8d0e6; text-transform: uppercase; letter-spacing: 1px; margin-top: 4px; }\n\n.cq-tldr { background: #e0f2fe; border-left: 4px solid #0284c7; padding: 18px 22px; border-radius: 6px; margin-bottom: 36px; font-size: 15px; line-height: 1.65; }\n.cq-tldr strong { color: #075985; }\n\n.cq-tbl-wrap { overflow-x: auto; margin: 16px 0 24px; }\ntable.cq-tbl { width: 100%; border-collapse: collapse; font-size: 14px; }\ntable.cq-tbl th { background: #0f4c81; color: #fff; padding: 11px 12px; text-align: left; font-weight: 600; }\ntable.cq-tbl td { padding: 11px 12px; border-bottom: 1px solid #e5e7eb; vertical-align: top; }\ntable.cq-tbl tr:nth-child(even) td { background: #f8fafc; }\n\n.cq-app-grid { display: grid; grid-template-columns: repeat(2, 1fr); gap: 16px; margin: 20px 0; }\n.cq-app-card { background: #f7f8fc; border-radius: 10px; padding: 22px; border-top: 3px solid #0284c7; transition: background 0.2s, transform 0.15s; }\n.cq-app-card:hover { background: #0f4c81; transform: translateY(-3px); }\n.cq-app-card h3 { color: #1a1a2e; margin-top: 0; transition: color 0.2s; }\n.cq-app-card:hover h3 { color: #fff; }\n.cq-app-card p { color: #475569; font-size: 14px; margin: 8px 0 0; transition: color 0.2s; }\n.cq-app-card:hover p { color: rgba(255,255,255,0.9); }\n.cq-app-card .cq-app-tag { display: inline-block; font-size: 10px; font-weight: 700; padding: 2px 8px; border-radius: 4px; background: #dbeafe; color: #075985; text-transform: uppercase; letter-spacing: 0.5px; margin-bottom: 8px; transition: background 0.2s, color 0.2s; }\n.cq-app-card:hover .cq-app-tag { background: rgba(255,255,255,0.18); color: #d8eaf3; }\n\ntable.cq-sku { width: 100%; border-collapse: collapse; font-size: 13px; margin: 14px 0; }\ntable.cq-sku th, table.cq-sku td { padding: 9px 10px; border-bottom: 1px solid #e5e7eb; text-align: left; }\ntable.cq-sku th { background: #ecf3f9; color: #0f4c81; font-weight: 700; }\ntable.cq-sku td:first-child { font-family: monospace; color: #0284c7; font-weight: 600; }\n\n.cq-decision { background: #fef3c7; border: 1px solid #fcd34d; border-radius: 10px; padding: 18px 22px; margin: 18px 0; }\n.cq-decision strong { color: #92400e; }\n\n.cq-cta { background: linear-gradient(135deg, #0f4c81, #2980b9); border-radius: 12px; padding: 30px 28px; text-align: center; color: #fff; margin: 40px 0; }\n.cq-cta h3 { color: #fff; font-size: 20px; margin: 0 0 10px; }\n.cq-cta p { color: #d8eaf3; margin: 0 0 18px; font-size: 15px; }\n.cq-cta a.cq-btn { display: inline-block; background: #fff; color: #0f4c81; padding: 12px 28px; border-radius: 8px; font-weight: 700; text-decoration: none; transition: background 0.15s, transform 0.15s; }\n.cq-cta a.cq-btn:hover { background: #ecf3f9; transform: translateY(-1px); }\n.cq-cta a.cq-btn-2 { background: transparent; color: #fff; border: 2px solid rgba(255,255,255,0.5); margin-left: 10px; }\n.cq-cta a.cq-btn-2:hover { background: rgba(255,255,255,0.1); }\n\n.cq-faq-item { border-bottom: 1px solid #e5e7eb; }\n.cq-faq-q { display: flex; justify-content: space-between; align-items: center; padding: 16px 0; cursor: pointer; font-weight: 600; color: #0f4c81; font-size: 16px; }\n.cq-faq-q::after { content: '+'; font-size: 22px; color: #94a3b8; transition: transform 0.2s; }\n.cq-faq-item.open .cq-faq-q::after { content: '\u2212'; }\n.cq-faq-a { max-height: 0; overflow: hidden; transition: max-height 0.3s ease; color: #475569; font-size: 15px; line-height: 1.65; }\n.cq-faq-item.open .cq-faq-a { max-height: 600px; padding-bottom: 18px; }\n\n@media (max-width: 600px) {\n  .cq-app-grid { grid-template-columns: 1fr; }\n  .cq-stats { grid-template-columns: repeat(2, 1fr); }\n  .cq-stat { border-right: none; border-bottom: 1px solid rgba(255,255,255,0.12); }\n  .cq-stat:nth-child(2n) { border-right: none; }\n}\n<\/style>\n\n<div class=\"cq-page\">\n\n<!-- HERO -->\n<div class=\"cq-hero\">\n  <div class=\"cq-hero-eyebrow\">Cuves \u00e0 circulation en quartz<\/div>\n  <p class=\"cq-hero-h1\">Cuves \u00e0 circulation en quartz pour l\u2019HPLC et l\u2019analyse en flux continu<\/p>\n  <p class=\"cq-hero-sub\">Cuves optiques \u00e0 trajet optique d\u00e9fini, avec raccordement en ligne \u2014 pour d\u00e9tecteurs HPLC, FIA\/CFA, suivi de proc\u00e9d\u00e9 et cin\u00e9tique en flux arr\u00eat\u00e9. Trajets de 0,5\u201310 mm, lumi\u00e8re deux voies et quatre voies, JGS1 qualit\u00e9 fluorescence.<\/p>\n  <div class=\"cq-stats\">\n    <div class=\"cq-stat\"><div class=\"cq-stat-num\">0,5\u201310 mm<\/div><div class=\"cq-stat-label\">Trajets optiques<\/div><\/div>\n    <div class=\"cq-stat\"><div class=\"cq-stat-num\">2 voies \/ 4 voies<\/div><div class=\"cq-stat-label\">G\u00e9om\u00e9trie de lumi\u00e8re<\/div><\/div>\n    <div class=\"cq-stat\"><div class=\"cq-stat-num\">140 \u00b5L+<\/div><div class=\"cq-stat-label\">Volume min.<\/div><\/div>\n    <div class=\"cq-stat\"><div class=\"cq-stat-num\">JGS1 \/ JGS2<\/div><div class=\"cq-stat-label\">Qualit\u00e9s de quartz<\/div><\/div>\n  <\/div>\n<\/div>\n\n<div class=\"cq-aidef\" style=\"background:#ecf3f9;border:1px solid #bae6fd;border-radius:10px;padding:18px 22px;margin:0 0 24px;\">\n<p style=\"margin:0;font-size:16px;line-height:1.65;color:#0c4a6e;\"><strong style=\"color:#075985;\">Une cuve \u00e0 circulation en quartz est<\/strong> une cuve de spectroscopie en quartz scell\u00e9e, dot\u00e9e de ports d\u2019entr\u00e9e et de sortie, con\u00e7ue pour mesurer l\u2019absorbance UV-Vis, l\u2019\u00e9mission de fluorescence ou la diffusion sur un flux d\u2019\u00e9chantillon en circulation \u2014 le plus souvent comme cuve de d\u00e9tection en HPLC et UPLC, en analyse par injection en flux (FIA), en analyse en flux continu (CFA) et dans les moniteurs de proc\u00e9d\u00e9 en ligne. Les trajets optiques vont de 0,5 mm (UPLC) \u00e0 100 mm (proc\u00e9d\u00e9 \/ analyse de traces), avec une g\u00e9om\u00e9trie de lumi\u00e8re deux voies pour l\u2019absorbance et quatre voies pour la fluorescence.<\/p>\n<\/div>\n\n<!-- TL;DR -->\n<div class=\"cq-tldr\">\n<strong>En bref \u2014 quand utiliser une cuve \u00e0 circulation en quartz :<\/strong>\nVous devez mesurer l\u2019absorbance UV-Vis, l\u2019\u00e9mission de fluorescence ou la diffusion sur un <span style=\"background:#fef3c7;padding:1px 5px;border-radius:3px;\">\u00e9chantillon en circulation<\/span> \u2014 \u00e9luant HPLC, flux d\u2019\u00e9chantillonneur automatique, eau de proc\u00e9d\u00e9, m\u00e9lange r\u00e9actionnel cin\u00e9tique. Une cuve \u00e0 circulation remplace une cuve statique par un corps en quartz scell\u00e9 dot\u00e9 d\u2019une tubulure d\u2019entr\u00e9e\/sortie, de sorte que l\u2019\u00e9chantillon traverse le trajet optique en continu. Choisissez la <strong>lumi\u00e8re 2 voies<\/strong> pour l\u2019absorbance\/la d\u00e9tection HPLC, la <strong>lumi\u00e8re 4 voies<\/strong> pour la fluorescence (collecte d\u2019\u00e9mission \u00e0 90\u00b0).\n<\/div>\n\n<!-- WHAT IS -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">D\u00e9finition<\/div>\n<h2>Qu\u2019est-ce qu\u2019une cuve \u00e0 circulation en quartz ?<\/h2>\n\n<p>Une cuve \u00e0 circulation en quartz \u2014 aussi appel\u00e9e <strong>cuve \u00e0 passage<\/strong> ou <strong>cuve \u00e0 circulation<\/strong> \u2014 est une chambre optique usin\u00e9e de pr\u00e9cision, \u00e0 deux ports de raccordement fluidique. L\u2019\u00e9chantillon entre par l\u2019entr\u00e9e, remplit le trajet optique, ressort par la sortie, et le spectrophotom\u00e8tre ou le fluorom\u00e8tre lit en continu \u00e0 mesure que le fluide passe.<\/p>\n\n<p>La construction est identique \u00e0 celle d\u2019une cuve statique en quartz \u00e0 tout autre \u00e9gard : <a href=\"https:\/\/machinedquartz.com\/fr\/coupure-uv-cuves-quartz\/\">quartz JGS1<\/a> pour une transmission UV int\u00e9grale jusqu\u2019\u00e0 185 nm, un parall\u00e9lisme \u00e0 \u00b10,005 mm sur les qualit\u00e9s Sintered 83 \/ Molded 83, et la m\u00eame correspondance de dimension Z que les cuves standard. Les seules diff\u00e9rences :<\/p>\n\n<ul>\n<li><strong>Corps scell\u00e9<\/strong> \u2014 pas de bouchon amovible ; la chambre optique est ferm\u00e9e en permanence.<\/li>\n<li><strong>Tubes d\u2019entr\u00e9e \/ sortie<\/strong> \u2014 g\u00e9n\u00e9ralement des embouts en quartz de 1\/16\u2033 ou 1\/8\u2033 de diam\u00e8tre ext\u00e9rieur, qui re\u00e7oivent une tubulure PTFE ou PEEK via des raccords sans collerette.<\/li>\n<li><strong>Volume interne d\u00e9fini<\/strong> \u2014 choisi pour \u00e9quilibrer la r\u00e9solution des pics HPLC (plus petit est mieux) et la limite de d\u00e9tection (trajet plus grand \u00d7 volume plus grand = plus de signal).<\/li>\n<\/ul>\n\n<p>La cuve se monte dans le m\u00eame porte-cuve qu\u2019une cuve statique ; la seule complexit\u00e9 ajout\u00e9e est de raccorder l\u2019entr\u00e9e et la sortie \u00e0 votre fluidique \u2014 typiquement la sortie de colonne (HPLC) ou une pompe p\u00e9ristaltique (FIA\/CFA).<\/p>\n<\/div>\n\n<!-- 2-WAY VS 4-WAY -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">G\u00e9om\u00e9trie de lumi\u00e8re<\/div>\n<h2>Cuves \u00e0 circulation lumi\u00e8re deux voies vs quatre voies<\/h2>\n\n<p>La plus grande d\u00e9cision \u00e0 la commande d\u2019une cuve \u00e0 circulation est de savoir si vous avez besoin d\u2019un acc\u00e8s optique <strong>deux voies<\/strong> (transmission seule) ou <strong>quatre voies<\/strong> (transmission + \u00e9mission \u00e0 90\u00b0).<\/p>\n\n<div class=\"cq-tbl-wrap\">\n<table class=\"cq-tbl\">\n<figure style=\"margin:24px 0;text-align:center;\">\n<svg viewBox=\"0 0 720 320\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" style=\"max-width:100%;height:auto;background:#fafdff;border-radius:10px;border:1px solid #bae6fd;padding:12px;\" role=\"img\" aria-label=\"Vue de dessus comparant une cuve \u00e0 circulation lumi\u00e8re deux voies \u00e0 deux faces polies et une cuve lumi\u00e8re quatre voies \u00e0 quatre faces polies avec d\u00e9tecteur d'\u00e9mission \u00e0 90 degr\u00e9s\">\n\n<!-- TWO-WAY -->\n<text x=\"170\" y=\"25\" text-anchor=\"middle\" font-size=\"14\" font-weight=\"700\" fill=\"#0f4c81\">Lumi\u00e8re 2 voies \u00b7 absorbance uniquement<\/text>\n\n<!-- cuvette body, top-down -->\n<rect x=\"100\" y=\"100\" width=\"140\" height=\"100\" fill=\"rgba(15,76,129,0.08)\" stroke=\"#0f4c81\" stroke-width=\"2\"\/>\n<!-- inlet\/outlet -->\n<rect x=\"160\" y=\"80\" width=\"20\" height=\"20\" fill=\"#475569\"\/>\n<text x=\"170\" y=\"74\" text-anchor=\"middle\" font-size=\"9\" fill=\"#475569\">entr\u00e9e<\/text>\n<rect x=\"160\" y=\"200\" width=\"20\" height=\"20\" fill=\"#475569\"\/>\n<text x=\"170\" y=\"234\" text-anchor=\"middle\" font-size=\"9\" fill=\"#475569\">sortie<\/text>\n<!-- TWO polished faces highlighted (left + right) -->\n<rect x=\"98\" y=\"100\" width=\"4\" height=\"100\" fill=\"#fbbf24\"\/>\n<rect x=\"238\" y=\"100\" width=\"4\" height=\"100\" fill=\"#fbbf24\"\/>\n<text x=\"80\" y=\"155\" text-anchor=\"middle\" font-size=\"10\" fill=\"#92400e\" font-weight=\"600\">poli<\/text>\n<text x=\"260\" y=\"155\" text-anchor=\"middle\" font-size=\"10\" fill=\"#92400e\" font-weight=\"600\">poli<\/text>\n<!-- Light beam: enters left, exits right -->\n<line x1=\"40\" y1=\"150\" x2=\"295\" y2=\"150\" stroke=\"#fbbf24\" stroke-width=\"3\" marker-end=\"url(#arrow)\"\/>\n<text x=\"50\" y=\"138\" font-size=\"10\" fill=\"#854d0e\">source UV\/Vis<\/text>\n<text x=\"295\" y=\"138\" text-anchor=\"end\" font-size=\"10\" fill=\"#854d0e\">\u2192 d\u00e9tecteur<\/text>\n<text x=\"170\" y=\"265\" text-anchor=\"middle\" font-size=\"11\" fill=\"#0c4a6e\" font-weight=\"600\">2 faces polies<\/text>\n<text x=\"170\" y=\"282\" text-anchor=\"middle\" font-size=\"9\" fill=\"#64748b\">D\u00e9tecteur UV HPLC, UV-Vis de proc\u00e9d\u00e9, CFA<\/text>\n<text x=\"170\" y=\"298\" text-anchor=\"middle\" font-size=\"9\" fill=\"#64748b\">co\u00fbt : 1\u00d7<\/text>\n\n<!-- Divider -->\n<line x1=\"380\" y1=\"40\" x2=\"380\" y2=\"300\" stroke=\"#bae6fd\" stroke-width=\"1\" stroke-dasharray=\"3,3\"\/>\n\n<!-- FOUR-WAY -->\n<text x=\"540\" y=\"25\" text-anchor=\"middle\" font-size=\"14\" font-weight=\"700\" fill=\"#0f4c81\">Lumi\u00e8re 4 voies \u00b7 absorbance + fluorescence<\/text>\n\n<rect x=\"470\" y=\"100\" width=\"140\" height=\"100\" fill=\"rgba(15,76,129,0.08)\" stroke=\"#0f4c81\" stroke-width=\"2\"\/>\n<rect x=\"530\" y=\"80\" width=\"20\" height=\"20\" fill=\"#475569\"\/>\n<text x=\"540\" y=\"74\" text-anchor=\"middle\" font-size=\"9\" fill=\"#475569\">entr\u00e9e<\/text>\n<rect x=\"530\" y=\"200\" width=\"20\" height=\"20\" fill=\"#475569\"\/>\n<text x=\"540\" y=\"234\" text-anchor=\"middle\" font-size=\"9\" fill=\"#475569\">sortie<\/text>\n<!-- FOUR polished faces -->\n<rect x=\"468\" y=\"100\" width=\"4\" height=\"100\" fill=\"#fbbf24\"\/>\n<rect x=\"608\" y=\"100\" width=\"4\" height=\"100\" fill=\"#fbbf24\"\/>\n<rect x=\"470\" y=\"98\" width=\"140\" height=\"4\" fill=\"#fbbf24\"\/>\n<rect x=\"470\" y=\"198\" width=\"140\" height=\"4\" fill=\"#fbbf24\"\/>\n<text x=\"450\" y=\"155\" text-anchor=\"middle\" font-size=\"9\" fill=\"#92400e\" font-weight=\"600\">poli<\/text>\n<text x=\"630\" y=\"155\" text-anchor=\"middle\" font-size=\"9\" fill=\"#92400e\" font-weight=\"600\">poli<\/text>\n<text x=\"540\" y=\"92\" text-anchor=\"middle\" font-size=\"9\" fill=\"#92400e\" font-weight=\"600\">poli<\/text>\n<text x=\"540\" y=\"218\" text-anchor=\"middle\" font-size=\"9\" fill=\"#92400e\" font-weight=\"600\">poli<\/text>\n<!-- Excitation beam: left to right -->\n<line x1=\"410\" y1=\"150\" x2=\"665\" y2=\"150\" stroke=\"#fbbf24\" stroke-width=\"3\" marker-end=\"url(#arrow)\"\/>\n<text x=\"420\" y=\"138\" font-size=\"10\" fill=\"#854d0e\">Excitation<\/text>\n<!-- Emission beam: 90\u00b0 down -->\n<line x1=\"540\" y1=\"160\" x2=\"540\" y2=\"240\" stroke=\"#a78bfa\" stroke-width=\"3\" marker-end=\"url(#arrowp)\"\/>\n<text x=\"555\" y=\"225\" font-size=\"10\" fill=\"#5b21b6\">\u00c9mission \u2193<\/text>\n<text x=\"555\" y=\"240\" font-size=\"9\" fill=\"#5b21b6\">(90\u00b0)<\/text>\n<text x=\"540\" y=\"265\" text-anchor=\"middle\" font-size=\"11\" fill=\"#0c4a6e\" font-weight=\"600\">4 faces polies \u00b7 g\u00e9om\u00e9trie \u00e0 90\u00b0<\/text>\n<text x=\"540\" y=\"282\" text-anchor=\"middle\" font-size=\"9\" fill=\"#64748b\">FLD HPLC, fluorescence, diffusion<\/text>\n<text x=\"540\" y=\"298\" text-anchor=\"middle\" font-size=\"9\" fill=\"#64748b\">co\u00fbt : 1,4\u20131,8\u00d7<\/text>\n\n<!-- Arrow marker definitions -->\n<defs>\n<marker id=\"arrow\" markerWidth=\"10\" markerHeight=\"10\" refX=\"8\" refY=\"3\" orient=\"auto\" markerUnits=\"strokeWidth\">\n<path d=\"M0,0 L8,3 L0,6 z\" fill=\"#fbbf24\"\/>\n<\/marker>\n<marker id=\"arrowp\" markerWidth=\"10\" markerHeight=\"10\" refX=\"8\" refY=\"3\" orient=\"auto\" markerUnits=\"strokeWidth\">\n<path d=\"M0,0 L8,3 L0,6 z\" fill=\"#a78bfa\"\/>\n<\/marker>\n<\/defs>\n<\/svg>\n<figcaption style=\"font-size:12px;color:#64748b;margin-top:6px;\">Vue de dessus : les cuves 2 voies n\u2019ont que des faces d\u2019entr\u00e9e + sortie ; les cuves 4 voies ajoutent le polissage des faces lat\u00e9rales pour la collecte d\u2019\u00e9mission de fluorescence \u00e0 90\u00b0.<\/figcaption>\n<\/figure>\n\n<thead><tr><th><\/th><th>Lumi\u00e8re deux voies<\/th><th>Lumi\u00e8re quatre voies<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Faces polies<\/td><td>2 (entr\u00e9e + sortie)<\/td><td>4 (entr\u00e9e + sortie + 2 faces lat\u00e9rales)<\/td><\/tr>\n<tr><td>Absorbance UV-Vis<\/td><td>\u2705 Optimale<\/td><td>\u2705 Oui (co\u00fbt l\u00e9g\u00e8rement sup\u00e9rieur)<\/td><\/tr>\n<tr><td>Fluorescence (90\u00b0)<\/td><td>\u274c Non<\/td><td>\u2705 Requise<\/td><\/tr>\n<tr><td>Diffusion \u00e0 angle droit<\/td><td>\u274c Non<\/td><td>\u2705 Oui<\/td><\/tr>\n<tr><td>Id\u00e9ale pour d\u00e9tecteur UV HPLC<\/td><td>\u2705<\/td><td>Surdimensionn\u00e9e<\/td><\/tr>\n<tr><td>Id\u00e9ale pour d\u00e9tecteur FLD<\/td><td>\u274c<\/td><td>\u2705 Requise<\/td><\/tr>\n<tr><td>Id\u00e9ale pour cin\u00e9tique en flux arr\u00eat\u00e9 + \u00e9mission<\/td><td>\u274c<\/td><td>\u2705<\/td><\/tr>\n<tr><td>Co\u00fbt<\/td><td>1\u00d7<\/td><td>1.4\u20131.8\u00d7<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"cq-decision\">\n<strong>R\u00e8gle de d\u00e9cision :<\/strong> Si vous ne mesurerez jamais que l\u2019absorbance, choisissez la 2 voies. S\u2019il y a la moindre chance d\u2019avoir besoin de fluorescence (d\u00e9tecteur actuel ou futur changement), choisissez la 4 voies \u2014 le surco\u00fbt est faible et vous \u00e9vitez de racheter la cuve plus tard.\n<\/div>\n<\/div>\n\n<!-- PATH LENGTH -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">Choix du trajet optique<\/div>\n<h2>Choisir le bon trajet optique pour l\u2019analyse en flux<\/h2>\n\n<p>Le trajet optique fixe la sensibilit\u00e9. La relation de Beer-Lambert (A = \u03b5\u00b7c\u00b7L) signifie que doubler le trajet optique double le signal \u00e0 concentration fixe. Mais en syst\u00e8me de flux, il y a un compromis : <strong>trajet plus long = volume interne plus grand = pic HPLC plus large<\/strong>.<\/p>\n\n<div class=\"cq-tbl-wrap\">\n<table class=\"cq-tbl\">\n<thead><tr><th>Trajet optique<\/th><th>Volume typique<\/th><th>Impact sur le pic HPLC<\/th><th>Meilleur cas d\u2019usage<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>0,5 mm<\/td><td>~140 \u00b5L<\/td><td>N\u00e9gligeable<\/td><td>UPLC, cin\u00e9tique rapide, \u00e9chantillons \u00e0 DO \u00e9lev\u00e9e<\/td><\/tr>\n<tr><td>1 mm<\/td><td>~350 \u00b5L<\/td><td>N\u00e9gligeable\u2013faible<\/td><td>D\u00e9tecteur UV HPLC standard (le plus courant)<\/td><\/tr>\n<tr><td>2 mm<\/td><td>~0,7 mL<\/td><td>Faible (\u0394<5 % pour des pics d\u20191 min)<\/td><td>HPLC de traces, analytes \u00e0 faible concentration<\/td><\/tr>\n<tr><td>3 mm<\/td><td>~1,05 mL<\/td><td>Notable sur les pics \u00e9troits<\/td><td>HPLC pr\u00e9parative, FIA<\/td><\/tr>\n<tr><td>10 mm<\/td><td>~3,5 mL<\/td><td>\u00c9largissement de pic majeur en HPLC analytique<\/td><td>Suivi de proc\u00e9d\u00e9, CFA, flux arr\u00eat\u00e9<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Pour l\u2019HPLC analytique, la plupart des utilisateurs choisissent un trajet de 1 mm. Les utilisateurs UPLC descendent souvent \u00e0 0,5 mm. Pour le suivi de proc\u00e9d\u00e9 ou la FIA o\u00f9 la r\u00e9solution des pics importe peu, le 10 mm donne 10\u00d7 le signal d\u2019absorbance d\u2019une cuve de 1 mm.<\/p>\n\n<p>Pour un traitement plus approfondi du compromis absorbance\u2013concentration, voir notre <a href=\"https:\/\/machinedquartz.com\/cuvette-path-length-by-analyte\/\">matrice de s\u00e9lection trajet optique par analyte<\/a> et le <a href=\"https:\/\/machinedquartz.com\/fr\/guide-trajet-optique-cuves\/\">guide complet du trajet optique<\/a>.<\/p>\n<\/div>\n\n<!-- APPLICATIONS -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">Applications<\/div>\n<h2>O\u00f9 l\u2019on utilise les cuves \u00e0 circulation en quartz<\/h2>\n\n<div class=\"cq-app-grid\">\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">HPLC<\/span>\n    <h3>D\u00e9tection UV \/ FLD en HPLC<\/h3>\n    <p>Cuve de d\u00e9tection en ligne pour l\u2019HPLC analytique. Un trajet de 1 mm \u00d7 350 \u00b5L de volume est le standard. La 4 voies est requise pour les d\u00e9tecteurs de fluorescence (Agilent 1260 FLD, Waters 2475).<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">UPLC<\/span>\n    <h3>UPLC \u00e0 colonne \u00e9troite<\/h3>\n    <p>Les pics sub-1 \u00b5L n\u00e9cessitent des cuves de trajet 0,5 mm \u00d7 ~140 \u00b5L pour \u00e9viter la distorsion des pics. Qualit\u00e9 JGS1 pour les analytes < 200 nm (peptides, pharma de faible masse mol\u00e9culaire).<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">FIA \/ CFA<\/span>\n    <h3>Injection en flux \/ flux continu<\/h3>\n    <p>Les cuves \u00e0 long trajet (10 mm ou plus) maximisent la sensibilit\u00e9 dans les autoanalyseurs (Skalar, Lachat QuikChem). Les contraintes de forme de pic se rel\u00e2chent ; la sensibilit\u00e9 li\u00e9e au trajet optique domine.<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">Proc\u00e9d\u00e9<\/span>\n    <h3>Suivi de proc\u00e9d\u00e9 en ligne<\/h3>\n    <p>\u00c9chantillonnage de bior\u00e9acteur, moniteurs de qualit\u00e9 d\u2019eau UV-T254, CQ des boissons en brasserie. Fabrication Sintered 83 pour la compatibilit\u00e9 avec la st\u00e9rilisation \u00e0 la vapeur et le NEP (CIP).<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">Cin\u00e9tique<\/span>\n    <h3>Cin\u00e9tique en flux arr\u00eat\u00e9<\/h3>\n    <p>M\u00e9lange rapide + trempe + lecture. 2 voies pour la cin\u00e9tique d\u2019absorbance, 4 voies quand la sonde fluorescente est la lecture. Cuves \u00e0 volume mort sub-milliseconde disponibles sur base sur mesure.<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">DLS<\/span>\n    <h3>Granulom\u00e9trie \/ DLS en flux<\/h3>\n    <p>Suivi de taille de particules en ligne en aval des proc\u00e9d\u00e9s de formulation. Lumi\u00e8re 4 voies pour la r\u00e9trodiffusion ou la d\u00e9tection \u00e0 90\u00b0 \u2014 voir aussi <a href=\"https:\/\/machinedquartz.com\/dls-particle-sizing-cuvettes\/\">le guide des cuves DLS<\/a>.<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">Spectro\u00e9lectro<\/span>\n    <h3>Spectro\u00e9lectrochimie<\/h3>\n    <p>Cuve \u00e0 \u00e9lectrode de travail avec acc\u00e8s optique. Trajets optiques sur mesure d\u00e8s 0,1 mm (couche mince) pour l\u2019UV-Vis in situ d\u2019interm\u00e9diaires redox.<\/p>\n  <\/div>\n  <div class=\"cq-app-card\">\n    <span class=\"cq-app-tag\">Gaz<\/span>\n    <h3>Absorption optique en phase gazeuse<\/h3>\n    <p>Cuves \u00e0 circulation scell\u00e9es pour l\u2019analyse de gaz d\u2019espace de t\u00eate (suivi NO\u2082, SO\u2082, ozone). Les variantes \u00e0 trajet de 100 mm offrent une sensibilit\u00e9 au niveau du ppb dans les instruments de chimie atmosph\u00e9rique.<\/p>\n  <\/div>\n<\/div>\n<\/div>\n\n<!-- FITTINGS -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">Raccords & raccordement<\/div>\n<h2>Raccords d\u2019entr\u00e9e \/ sortie et compatibilit\u00e9 des tubulures<\/h2>\n\n<p>Les cuves \u00e0 circulation MachinedQuartz sont livr\u00e9es avec des embouts en quartz de 4 mm, 5 mm, 7 mm et 10 mm de diam\u00e8tre ext\u00e9rieur (indiqu\u00e9 dans le SKU comme \u00ab 4 mm DE \u00bb, etc.). Ils re\u00e7oivent en standard :<\/p>\n\n<ul>\n<li><strong>Tubulure PEEK 1\/16\u2033 DE<\/strong> via raccords sans collerette (filetage 10\u201332, s\u00e9rie IDEX P-200) \u2014 la plus courante pour l\u2019int\u00e9gration HPLC.<\/li>\n<li><strong>Tubulure inox 1\/16\u2033 DE<\/strong> via raccords Valco ou Swagelok \u2014 pour les essais \u00e0 haute pression ou r\u00e9sistants aux solvants.<\/li>\n<li><strong>Tubulure silicone ou Tygon 3 mm ou 1\/8\u2033 DE<\/strong> via raccord \u00e0 pince \u2014 pour la FIA basse pression, la CFA, les analyseurs \u00e0 pompe p\u00e9ristaltique.<\/li>\n<li><strong>Manchons de compression PTFE<\/strong> pour le couplage en ligne quartz-\u00e0-quartz sur les empilements multi-cuves.<\/li>\n<\/ul>\n\n<p>Pour les pressions UHPLC (> 600 bar), le corps en quartz lui-m\u00eame r\u00e9siste de fa\u00e7on fiable jusqu\u2019\u00e0 200 bar ; au-del\u00e0, il faut une cuve \u00e0 circulation sur mesure \u00e0 collier renforc\u00e9. Pr\u00e9cisez votre pression de service maximale \u00e0 la demande de devis.<\/p>\n<\/div>\n\n\n<div data-cq-photo-row-marker=\"1\" style=\"margin:36px 0;padding:24px 26px;background:#f8fafc;border-radius:12px;border:1px solid #e2e8f0;\">\n<div style=\"font-size:11px;font-weight:700;letter-spacing:1.5px;text-transform:uppercase;color:#475569;margin-bottom:6px;\">Catalogue de cuves \u00e0 circulation<\/div>\n<h3 style=\"font-size:18px;font-weight:700;color:#1a2a6c;margin:0 0 16px;line-height:1.3;\">Cuves \u00e0 circulation en stock, tous trajets optiques et g\u00e9om\u00e9tries de lumi\u00e8re<\/h3>\n<div style=\"display:grid;grid-template-columns:repeat(4,1fr);gap:14px;margin-bottom:14px;\">\n<a href=\"https:\/\/machinedquartz.com\/product\/quartz-1mm-flow-cuvette-molded-83-two-way-c012ws4\/\" style=\"display:block;background:#fff;border:1px solid #e2e8f0;border-radius:8px;padding:10px;text-decoration:none;transition:transform 0.15s,box-shadow 0.15s;\" onmouseover=\"this.style.transform='translateY(-2px)';this.style.boxShadow='0 6px 20px rgba(35,58,149,0.12)'\" onmouseout=\"this.style.transform='translateY(0)';this.style.boxShadow='none'\"><div style=\"aspect-ratio:1\/1;background:#fafafa;border-radius:6px;overflow:hidden;display:flex;align-items:center;justify-content:center;margin-bottom:8px;\"><img decoding=\"async\" src=\"https:\/\/machinedquartz.com\/wp-content\/uploads\/2025\/07\/C012WS4-1mm-4mm-OD-Diameter-Flow-Cuvette-0.35ml-Two-way-Light-1pc-ea.jpg\" alt=\"Quartz 1 mm\" loading=\"lazy\" style=\"max-width:100%;max-height:100%;object-fit:contain;\"\/><\/div><div style=\"font-family:monospace;font-size:11px;color:#233a95;font-weight:700;margin-bottom:2px;\">C012WS4<\/div><div style=\"font-size:11px;color:#475569;line-height:1.4;\">Quartz 1 mm<\/div><\/a>\n<a href=\"https:\/\/machinedquartz.com\/product\/quartz-1mm-flow-cuvette-molded-83-four-way-c014ws3\/\" style=\"display:block;background:#fff;border:1px solid #e2e8f0;border-radius:8px;padding:10px;text-decoration:none;transition:transform 0.15s,box-shadow 0.15s;\" onmouseover=\"this.style.transform='translateY(-2px)';this.style.boxShadow='0 6px 20px rgba(35,58,149,0.12)'\" onmouseout=\"this.style.transform='translateY(0)';this.style.boxShadow='none'\"><div style=\"aspect-ratio:1\/1;background:#fafafa;border-radius:6px;overflow:hidden;display:flex;align-items:center;justify-content:center;margin-bottom:8px;\"><img decoding=\"async\" src=\"https:\/\/machinedquartz.com\/wp-content\/uploads\/2025\/07\/C014WS3-1mm-4mm-OD-Diameter-Flow-Cuvette-0.35ml-Four-Way-Light-1pc-ea.jpg\" alt=\"Quartz 1 mm\" loading=\"lazy\" style=\"max-width:100%;max-height:100%;object-fit:contain;\"\/><\/div><div style=\"font-family:monospace;font-size:11px;color:#233a95;font-weight:700;margin-bottom:2px;\">C014WS3<\/div><div style=\"font-size:11px;color:#475569;line-height:1.4;\">Quartz 1 mm<\/div><\/a>\n<a href=\"https:\/\/machinedquartz.com\/product\/quartz-2mm-flow-cuvette-molded-83-two-way-c022ws7\/\" style=\"display:block;background:#fff;border:1px solid #e2e8f0;border-radius:8px;padding:10px;text-decoration:none;transition:transform 0.15s,box-shadow 0.15s;\" onmouseover=\"this.style.transform='translateY(-2px)';this.style.boxShadow='0 6px 20px rgba(35,58,149,0.12)'\" onmouseout=\"this.style.transform='translateY(0)';this.style.boxShadow='none'\"><div style=\"aspect-ratio:1\/1;background:#fafafa;border-radius:6px;overflow:hidden;display:flex;align-items:center;justify-content:center;margin-bottom:8px;\"><img decoding=\"async\" src=\"https:\/\/machinedquartz.com\/wp-content\/uploads\/2025\/07\/C022WS7-2mm-5mm-OD-Diameter-Flow-Cuvette-0.7ml-Two-way-Light-1pc-ea.jpg\" alt=\"Quartz 2 mm\" loading=\"lazy\" style=\"max-width:100%;max-height:100%;object-fit:contain;\"\/><\/div><div style=\"font-family:monospace;font-size:11px;color:#233a95;font-weight:700;margin-bottom:2px;\">C022WS7<\/div><div style=\"font-size:11px;color:#475569;line-height:1.4;\">Quartz 2 mm<\/div><\/a>\n<a href=\"https:\/\/machinedquartz.com\/product\/quartz-3mm-fluorescence-flow-cuvette-molded-83-four-way-c034ws\/\" style=\"display:block;background:#fff;border:1px solid #e2e8f0;border-radius:8px;padding:10px;text-decoration:none;transition:transform 0.15s,box-shadow 0.15s;\" onmouseover=\"this.style.transform='translateY(-2px)';this.style.boxShadow='0 6px 20px rgba(35,58,149,0.12)'\" onmouseout=\"this.style.transform='translateY(0)';this.style.boxShadow='none'\"><div style=\"aspect-ratio:1\/1;background:#fafafa;border-radius:6px;overflow:hidden;display:flex;align-items:center;justify-content:center;margin-bottom:8px;\"><img decoding=\"async\" src=\"https:\/\/machinedquartz.com\/wp-content\/uploads\/2025\/07\/C034WS-3mm-4mm-OD-Diameter-Flow-Cuvette-300ul-Four-Way-Light-1pc-ea.jpg\" alt=\"Quartz 3 mm\" loading=\"lazy\" style=\"max-width:100%;max-height:100%;object-fit:contain;\"\/><\/div><div style=\"font-family:monospace;font-size:11px;color:#233a95;font-weight:700;margin-bottom:2px;\">C034WS<\/div><div style=\"font-size:11px;color:#475569;line-height:1.4;\">Quartz 3 mm<\/div><\/a>\n<\/div>\n<p style=\"margin:0;font-size:13px;color:#64748b;line-height:1.55;\">Trajet de 0,5 mm \u00e0 10 mm, lumi\u00e8re 2 voies et 4 voies, raccordement 4\u201310 mm DE. Chacune exp\u00e9di\u00e9e le jour m\u00eame depuis l\u2019entrep\u00f4t am\u00e9ricain.<\/p>\n<\/div>\n\n\n<!-- SKU TABLE -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">Gamme de produits<\/div>\n<h2>Catalogue de cuves \u00e0 circulation MachinedQuartz<\/h2>\n\n<p>SKU en stock s\u00e9lectionn\u00e9s dans notre gamme de 50+ cuves \u00e0 circulation :<\/p>\n\n<table class=\"cq-sku\">\n<thead><tr><th>SKU<\/th><th>Trajet<\/th><th>Lumi\u00e8re<\/th><th>DE<\/th><th>Volume<\/th><th>Fab.<\/th><th>Id\u00e9ale pour<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>C0.54WS<\/td><td>0,5 mm<\/td><td>4 voies<\/td><td>4 mm<\/td><td>140 \u00b5L<\/td><td>Molded 83<\/td><td>FLD UPLC<\/td><\/tr>\n<tr><td>C012WS4<\/td><td>1 mm<\/td><td>2 voies<\/td><td>4 mm<\/td><td>350 \u00b5L<\/td><td>Molded 83<\/td><td>UV HPLC<\/td><\/tr>\n<tr><td>C014WS3<\/td><td>1 mm<\/td><td>4 voies<\/td><td>4 mm<\/td><td>350 \u00b5L<\/td><td>Molded 83<\/td><td>FLD HPLC<\/td><\/tr>\n<tr><td>C022WS7<\/td><td>2 mm<\/td><td>2 voies<\/td><td>5 mm<\/td><td>0,7 mL<\/td><td>Molded 83<\/td><td>UV HPLC de traces<\/td><\/tr>\n<tr><td>C024WS3<\/td><td>2 mm<\/td><td>4 voies<\/td><td>4 mm<\/td><td>0,7 mL<\/td><td>Molded 83<\/td><td>FLD HPLC de traces<\/td><\/tr>\n<tr><td>C024WS4<\/td><td>2 mm<\/td><td>4 voies<\/td><td>5 mm<\/td><td>0,7 mL<\/td><td>Molded 83<\/td><td>FLD HPLC de traces (raccordement 5 mm DE)<\/td><\/tr>\n<tr><td>C034WS<\/td><td>3 mm<\/td><td>4 voies<\/td><td>4 mm<\/td><td>300 \u00b5L<\/td><td>Molded 83<\/td><td>Flux de fluorescence + faible volume<\/td><\/tr>\n<tr><td>C2.52CS1<\/td><td>2,5 mm<\/td><td>2 voies<\/td><td>\u2014<\/td><td>\u00c9chantillon<\/td><td>Standard 80<\/td><td>Flux d\u2019\u00e9chantillon \/ FIA<\/td><\/tr>\n<tr><td>C102WS15<\/td><td>10 mm<\/td><td>2 voies<\/td><td>10 mm<\/td><td>3,5 mL<\/td><td>Molded 83<\/td><td>UV proc\u00e9d\u00e9 \/ CFA<\/td><\/tr>\n<tr><td>C102WS16<\/td><td>10 mm<\/td><td>2 voies<\/td><td>4 mm<\/td><td>3,5 mL<\/td><td>Molded 83<\/td><td>Long trajet, pic HPLC acceptable<\/td><\/tr>\n<tr><td>C104WS9<\/td><td>10 mm<\/td><td>4 voies<\/td><td>4 mm<\/td><td>3,5 mL<\/td><td>Molded 83<\/td><td>Fluorescence de proc\u00e9d\u00e9<\/td><\/tr>\n<tr><td>C104WS10<\/td><td>10 mm<\/td><td>4 voies<\/td><td>4 mm<\/td><td>3,5 mL<\/td><td>Molded 83<\/td><td>Fluorescence de proc\u00e9d\u00e9 (alt.)<\/td><\/tr>\n<tr><td>C012WS6<\/td><td>10 mm<\/td><td>4 voies<\/td><td>\u2014<\/td><td>3,5 mL<\/td><td>Molded 83<\/td><td>Personnalisable, OEM<\/td><\/tr>\n<\/tbody>\n<\/table>\n\n<p style=\"font-size: 14px; color: #64748b; margin-top: 8px;\">\u2192 Parcourir toutes les <a href=\"https:\/\/machinedquartz.com\/product-category\/products\/cuvettes\/quartz-flow-cells\/\">cuves \u00e0 circulation en quartz<\/a> \u00b7 Voir le <a href=\"https:\/\/machinedquartz.com\/cuvettes-and-cells-size-chart\/\">tableau complet des tailles de cuves<\/a><\/p>\n<\/div>\n\n<!-- MAINTENANCE -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">Entretien<\/div>\n<h2>Nettoyage et pr\u00e9vention du report<\/h2>\n\n<p>Le report est la cause n\u00b01 de remplacement pr\u00e9matur\u00e9 des cuves \u00e0 circulation. Le protocole compte :<\/p>\n\n<h3>Rin\u00e7age de routine (entre les essais)<\/h3>\n<ol>\n<li>10 volumes de colonne de phase mobile au d\u00e9bit de travail.<\/li>\n<li>En cas de changement de classe de solvant (organique \u2194 aqueux), d\u2019abord 20 volumes de colonne \u00e0 composition interm\u00e9diaire.<\/li>\n<li>Purge \u00e0 sec \u00e0 l\u2019azote si stockage \u00e0 sec pour la nuit.<\/li>\n<\/ol>\n\n<h3>Nettoyage en profondeur (hebdomadaire ou apr\u00e8s \u00e9chantillon \u00e0 fort effet de matrice)<\/h3>\n<ol>\n<li>Rincez au HNO\u2083 \u00e0 5 % (pour les r\u00e9sidus biologiques) ou au NaOH \u00e0 5 % (pour les acides organiques), 30 min de contact statique, puis rin\u00e7age \u00e0 l\u2019eau.<\/li>\n<li>Si la d\u00e9rive de ligne de base d\u2019absorbance est > 0,005 UA apr\u00e8s rin\u00e7age, passez la cuve aux ultrasons ex situ dans une solution de Hellmanex III ou d\u2019Alconox pendant 10 min.<\/li>\n<li>Rin\u00e7age final : eau qualit\u00e9 HPLC, puis m\u00e9thanol, puis solvant de stockage.<\/li>\n<\/ol>\n\n<h3>\u00c0 ne jamais faire<\/h3>\n<ul>\n<li>HF ou BOE \u2014 grave le quartz, cause des dommages irr\u00e9versibles aux fen\u00eatres.<\/li>\n<li>Brosses m\u00e9talliques ou tampons \u00e0 r\u00e9curer \u2014 rayent les faces polies (toute rayure > 1 \u00b5m d\u00e9grade le bruit de ligne de base).<\/li>\n<li>Choc thermique brutal \u2014 passer de \u221220 \u00b0C \u00e0 80 \u00b0C en quelques secondes peut fissurer une cuve scell\u00e9e. \u00c9quilibrez \u00e0 5 \u00b0C\/min au maximum.<\/li>\n<\/ul>\n\n<p>Protocole complet : <a href=\"https:\/\/machinedquartz.com\/fr\/protocole-nettoyage-cuves\/\">protocole de nettoyage des cuves avec 10 recettes de solvants<\/a>.<\/p>\n<\/div>\n\n<!-- CTA -->\n<div class=\"cq-cta\">\n  <h3>Besoin d\u2019un trajet optique, d\u2019un DE ou d\u2019un raccord sur mesure ?<\/h3>\n  <p>MachinedQuartz fabrique des cuves \u00e0 circulation sur plan en 4 \u00e0 6 semaines, MOQ 1. Envoyez votre mod\u00e8le d\u2019HPLC et de d\u00e9tecteur et nous sp\u00e9cifierons la cuve pour vous.<\/p>\n  <a class=\"cq-btn\" href=\"https:\/\/machinedquartz.com\/contact\/\">Demander un devis<\/a>\n  <a class=\"cq-btn cq-btn-2\" href=\"https:\/\/machinedquartz.com\/product-category\/products\/cuvettes\/quartz-flow-cells\/\">Parcourir les SKU en stock<\/a>\n<\/div>\n\n<!-- FAQ -->\n<div class=\"cq-section\">\n<div class=\"cq-section-label\">FAQ<\/div>\n<h2>Questions fr\u00e9quentes<\/h2>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Quelle est la diff\u00e9rence entre une cuve \u00e0 circulation et une \u00ab flow cuvette \u00bb ?<\/div>\n  <div class=\"cq-faq-a\"><p>Les termes sont employ\u00e9s indiff\u00e9remment. \u00ab Flow cell \u00bb est plus courant en HPLC et en analyseurs de proc\u00e9d\u00e9 ; \u00ab flow cuvette \u00bb l\u2019est plus en recherche et en spectroscopie de paillasse. Les deux d\u00e9signent le m\u00eame dispositif \u2014 une chambre optique scell\u00e9e en quartz avec raccordement d\u2019entr\u00e9e\/sortie.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Puis-je utiliser mon porte-cuve standard avec une cuve \u00e0 circulation ?<\/div>\n  <div class=\"cq-faq-a\"><p>G\u00e9n\u00e9ralement oui. Les cuves \u00e0 circulation MachinedQuartz \u00e0 empreinte de corps 12,5 \u00d7 12,5 mm entrent dans n\u2019importe quel porte-cuve de spectrophotom\u00e8tre standard de 1 cm. Les tubes de raccordement sortent par le haut, donc le couvercle du porte-cuve doit \u00eatre ouvert ou modifi\u00e9. Pour les cuves de d\u00e9tecteur HPLC, le porte-cuve est int\u00e9gr\u00e9 au module d\u00e9tecteur \u2014 v\u00e9rifiez que les dimensions de la cuve correspondent \u00e0 votre mod\u00e8le de d\u00e9tecteur pr\u00e9cis (Agilent G7117A, Waters 2998, Shimadzu SPD-M40, etc.).<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Quelle est la contre-pression maximale qu\u2019une cuve \u00e0 circulation en quartz peut supporter ?<\/div>\n  <div class=\"cq-faq-a\"><p>Les cuves \u00e0 circulation MQ standard sont qualifi\u00e9es \u00e0 200 bar (2 900 psi) en continu. Les applications UHPLC au-dessus de 400 bar exigent une cuve sur mesure \u00e0 collier renforc\u00e9 \u2014 pr\u00e9cisez la pression maximale de votre syst\u00e8me \u00e0 la commande. Le quartz c\u00e8de par fuite au collier avant toute rupture catastrophique du corps : vous verrez un suintement lent bien avant tout incident de s\u00e9curit\u00e9.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Comment accorder le volume de la cuve \u00e0 circulation \u00e0 la largeur de mes pics HPLC ?<\/div>\n  <div class=\"cq-faq-a\"><p>R\u00e8gle g\u00e9n\u00e9rale : le volume de la cuve doit \u00eatre \u2264 10 % du volume du pic. Pour une HPLC analytique avec des pics de 30 secondes \u00e0 1 mL\/min, le volume de pic = 500 \u00b5L, donc le volume de la cuve doit \u00eatre \u2264 50 \u00b5L. C\u2019est pourquoi la plupart des d\u00e9tecteurs HPLC analytiques utilisent une cuve de 1 mm \u00d7 350 \u00b5L \u2014 un peu plus grande que l\u2019id\u00e9al mais accept\u00e9e comme compromis pratique. Les pics UPLC (5 secondes de large) n\u00e9cessitent 140 \u00b5L ou moins.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Ai-je besoin de quartz, ou une cuve \u00e0 circulation en verre optique suffira-t-elle ?<\/div>\n  <div class=\"cq-faq-a\"><p>Pour les d\u00e9tecteurs UV (190\u2013350 nm), il vous faut du quartz (selon les <a href=\"https:\/\/www.uspnf.com\/\" target=\"_blank\" rel=\"noopener\">recommandations de spectrophotom\u00e9trie de l\u2019USP <851><\/a>) \u2014 le verre optique coupe vers 320 nm. Pour les d\u00e9tecteurs visible uniquement (350\u2013800 nm), le verre optique convient et co\u00fbte moins cher. Les d\u00e9tecteurs NIR (au-dessus de 1 100 nm) n\u00e9cessitent du quartz qualit\u00e9 JGS3 pour conserver la transmission. Voir <a href=\"https:\/\/machinedquartz.com\/fr\/cuve-quartz-vs-verre\/\">quartz vs verre pour les cuves<\/a> pour le d\u00e9tail complet.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Une cuve \u00e0 circulation peut-elle servir de cuve statique ?<\/div>\n  <div class=\"cq-faq-a\"><p>Oui \u2014 remplissez-la d\u2019\u00e9chantillon par l\u2019entr\u00e9e, bouchez les deux ports, et utilisez-la comme n\u2019importe quelle cuve scell\u00e9e. La performance optique est identique. Le seul l\u00e9ger inconv\u00e9nient est le corps un peu plus encombrant (\u00e0 cause des embouts d\u2019entr\u00e9e\/sortie), qui peut compliquer l\u2019ajustement au porte-cuve sur certains instruments compacts.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Combien de temps dure une cuve \u00e0 circulation en quartz en HPLC de production ?<\/div>\n  <div class=\"cq-faq-a\"><p>Avec un nettoyage correct et sans solvants agressifs, 5 ans et plus d\u2019usage quotidien est typique. Les deux principaux modes de d\u00e9faillance sont la rayure des fen\u00eatres par des \u00e9chantillons charg\u00e9s en particules (utilisez toujours un filtre 0,45 \u00b5m en amont) et la fuite au collier par des raccords trop serr\u00e9s (serrage \u00e0 la main + 1\/4 de tour est la consigne pour le PEEK sans collerette). Le quartz lui-m\u00eame ne se d\u00e9grade pas.<\/p><\/div>\n<\/div>\n\n<div class=\"cq-faq-item\">\n  <div class=\"cq-faq-q\">Quel est le d\u00e9lai pour une cuve \u00e0 circulation sur mesure ?<\/div>\n  <div class=\"cq-faq-a\"><p>Les SKU en stock partent le jour m\u00eame de notre entrep\u00f4t am\u00e9ricain (5 \u00e0 8 jours jusqu\u2019au labo). G\u00e9om\u00e9tries sur mesure : 4 \u00e0 6 semaines pour les trajets optiques jusqu\u2019\u00e0 10 mm avec raccords standard, 6 \u00e0 8 semaines pour les DE non standard, colliers renforc\u00e9s ou corps surdimensionn\u00e9s. MOQ 1 \u2014 aucune quantit\u00e9 minimale de commande pour les conceptions sur mesure.<\/p><\/div>\n<\/div>\n\n<\/div>\n\n<!-- BOTTOM CTA -->\n<div class=\"cq-cta\" style=\"margin-top: 50px;\">\n  <h3>Aidez-nous \u00e0 sp\u00e9cifier la bonne cuve pour votre d\u00e9tecteur<\/h3>\n  <p>Envoyez-nous le num\u00e9ro de mod\u00e8le de votre HPLC\/FLD et nous croiserons les compatibilit\u00e9s \u2014 r\u00e9ponse typique sous 24 heures.<\/p>\n  <a class=\"cq-btn\" href=\"https:\/\/machinedquartz.com\/contact\/\">\u00c9crire au service commercial<\/a>\n  <a class=\"cq-btn cq-btn-2\" href=\"https:\/\/machinedquartz.com\/fr\/guide-selection-cuves\/\">Lire le guide de s\u00e9lection<\/a>\n<\/div>\n\n<\/div>\n\n<script>\ndocument.querySelectorAll('.cq-faq-q').forEach(function(q) {\n  q.addEventListener('click', function() {\n    var item = this.closest('.cq-faq-item');\n    var isOpen = item.classList.contains('open');\n    document.querySelectorAll('.cq-faq-item').forEach(function(i){ i.classList.remove('open'); });\n    if (!isOpen) item.classList.add('open');\n  });\n});\n<\/script>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Article\",\n  \"headline\": \"Cuves \u00e0 circulation en quartz pour l'HPLC et l'analyse en flux continu\",\n  \"description\": \"Cuves \u00e0 circulation en quartz pour la d\u00e9tection UV\/FLD en HPLC, l'UPLC, la FIA, le suivi de proc\u00e9d\u00e9 et la cin\u00e9tique en flux arr\u00eat\u00e9. Trajets de 0,5\u201310 mm, lumi\u00e8re 2 et 4 voies, qualit\u00e9s JGS1\/JGS2.\",\n  \"datePublished\": \"2026-04-06\",\n  \"dateModified\": \"2026-04-08\",\n  \"author\": {\n    \"@type\": \"Organization\",\n    \"name\": \"MachinedQuartz\"\n  },\n  \"publisher\": {\n    \"@type\": \"Organization\",\n    \"name\": \"MachinedQuartz\",\n    \"url\": \"https:\/\/machinedquartz.com\"\n  },\n  \"mainEntityOfPage\": {\n    \"@type\": \"WebPage\",\n    \"@id\": \"https:\/\/machinedquartz.com\/fr\/cuves-circulation-quartz-hplc\/\"\n  },\n  \"inLanguage\": \"fr\"\n}\n<\/script>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"inLanguage\": \"fr\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Quelle est la diff\u00e9rence entre une cuve \u00e0 circulation et une \u00ab flow cuvette \u00bb ?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Les termes sont employ\u00e9s indiff\u00e9remment. \u00ab Flow cell \u00bb est plus courant en HPLC et en analyseurs de proc\u00e9d\u00e9 ; \u00ab flow cuvette \u00bb l'est plus en recherche et en spectroscopie de paillasse. Les deux d\u00e9signent le m\u00eame dispositif \u2014 une chambre optique scell\u00e9e en quartz avec raccordement d'entr\u00e9e\/sortie.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Puis-je utiliser mon porte-cuve standard avec une cuve \u00e0 circulation ?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"G\u00e9n\u00e9ralement oui. Les cuves \u00e0 circulation MachinedQuartz \u00e0 empreinte de corps 12,5 \u00d7 12,5 mm entrent dans n'importe quel porte-cuve de spectrophotom\u00e8tre standard de 1 cm. Les tubes de raccordement sortent par le haut, donc le couvercle du porte-cuve doit \u00eatre ouvert ou modifi\u00e9. Pour les cuves de d\u00e9tecteur HPLC, le porte-cuve est int\u00e9gr\u00e9 au module d\u00e9tecteur \u2014 v\u00e9rifiez que les dimensions correspondent \u00e0 votre mod\u00e8le pr\u00e9cis (Agilent G7117A, Waters 2998, Shimadzu SPD-M40, etc.).\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Quelle est la contre-pression maximale qu'une cuve \u00e0 circulation en quartz peut supporter ?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Les cuves \u00e0 circulation MQ standard sont qualifi\u00e9es \u00e0 200 bar (2 900 psi) en continu. Les applications UHPLC au-dessus de 400 bar exigent une cuve sur mesure \u00e0 collier renforc\u00e9 \u2014 pr\u00e9cisez la pression maximale de votre syst\u00e8me \u00e0 la commande. Le quartz c\u00e8de par fuite au collier avant toute rupture catastrophique du corps : vous verrez un suintement lent bien avant tout incident de s\u00e9curit\u00e9.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Comment accorder le volume de la cuve \u00e0 circulation \u00e0 la largeur de mes pics HPLC ?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"R\u00e8gle g\u00e9n\u00e9rale : le volume de la cuve doit \u00eatre \u2264 10 % du volume du pic. Pour une HPLC analytique avec des pics de 30 secondes \u00e0 1 mL\/min, le volume de pic = 500 \u00b5L, donc le volume de la cuve doit \u00eatre \u2264 50 \u00b5L. C'est pourquoi la plupart des d\u00e9tecteurs HPLC analytiques utilisent une cuve de 1 mm \u00d7 350 \u00b5L \u2014 un peu plus grande que l'id\u00e9al mais accept\u00e9e comme compromis pratique. Les pics UPLC (5 secondes de large) n\u00e9cessitent 140 \u00b5L ou moins.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Ai-je besoin de quartz, ou une cuve \u00e0 circulation en verre optique suffira-t-elle ?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Pour les d\u00e9tecteurs UV (190\u2013350 nm), il vous faut du quartz (selon les recommandations de spectrophotom\u00e9trie de l'USP <851>) \u2014 le verre optique coupe vers 320 nm. Pour les d\u00e9tecteurs visible uniquement (350\u2013800 nm), le verre optique convient et co\u00fbte moins cher. Les d\u00e9tecteurs NIR (au-dessus de 1 100 nm) n\u00e9cessitent du quartz qualit\u00e9 JGS3 pour conserver la transmission.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Une cuve \u00e0 circulation peut-elle servir de cuve statique ?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Oui \u2014 remplissez-la d'\u00e9chantillon par l'entr\u00e9e, bouchez les deux ports, et utilisez-la comme n'importe quelle cuve scell\u00e9e. La performance optique est identique. Le seul l\u00e9ger inconv\u00e9nient est le corps un peu plus encombrant (\u00e0 cause des embouts d'entr\u00e9e\/sortie), qui peut compliquer l'ajustement au porte-cuve sur certains instruments compacts.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Combien de temps dure une cuve \u00e0 circulation en quartz en HPLC de production ?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Avec un nettoyage correct et sans solvants agressifs, 5 ans et plus d'usage quotidien est typique. Les deux principaux modes de d\u00e9faillance sont la rayure des fen\u00eatres par des \u00e9chantillons charg\u00e9s en particules (utilisez toujours un filtre 0,45 \u00b5m en amont) et la fuite au collier par des raccords trop serr\u00e9s (serrage \u00e0 la main + 1\/4 de tour pour le PEEK sans collerette). Le quartz lui-m\u00eame ne se d\u00e9grade pas.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Quel est le d\u00e9lai pour une cuve \u00e0 circulation sur mesure ?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Les SKU en stock partent le jour m\u00eame de notre entrep\u00f4t am\u00e9ricain (5 \u00e0 8 jours jusqu'au labo). G\u00e9om\u00e9tries sur mesure : 4 \u00e0 6 semaines pour les trajets optiques jusqu'\u00e0 10 mm avec raccords standard, 6 \u00e0 8 semaines pour les DE non standard, colliers renforc\u00e9s ou corps surdimensionn\u00e9s. MOQ 1 \u2014 aucune quantit\u00e9 minimale de commande pour les conceptions sur mesure.\"\n      }\n    }\n  ]\n}\n<\/script>\n\n\n","protected":false},"excerpt":{"rendered":"<p>Cuves \u00e0 circulation en quartz Cuves \u00e0 circulation en quartz pour l\u2019HPLC et l\u2019analyse en flux continu Cuves optiques \u00e0 trajet optique d\u00e9fini, avec raccordement en ligne \u2014 pour d\u00e9tecteurs HPLC, FIA\/CFA, suivi de proc\u00e9d\u00e9 et cin\u00e9tique en flux arr\u00eat\u00e9. Trajets de 0,5\u201310 mm, lumi\u00e8re deux voies et quatre voies, JGS1 qualit\u00e9 fluorescence. 0,5\u201310 mm<\/p>\n<div class=\"klb-readmore entry-button\"><a class=\"button\" href=\"https:\/\/machinedquartz.com\/fr\/cuves-circulation-quartz-hplc\/\">Read More<\/a><\/div>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-98747","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/machinedquartz.com\/fr\/wp-json\/wp\/v2\/posts\/98747","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/machinedquartz.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/machinedquartz.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/machinedquartz.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/machinedquartz.com\/fr\/wp-json\/wp\/v2\/comments?post=98747"}],"version-history":[{"count":2,"href":"https:\/\/machinedquartz.com\/fr\/wp-json\/wp\/v2\/posts\/98747\/revisions"}],"predecessor-version":[{"id":98878,"href":"https:\/\/machinedquartz.com\/fr\/wp-json\/wp\/v2\/posts\/98747\/revisions\/98878"}],"wp:attachment":[{"href":"https:\/\/machinedquartz.com\/fr\/wp-json\/wp\/v2\/media?parent=98747"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/machinedquartz.com\/fr\/wp-json\/wp\/v2\/categories?post=98747"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/machinedquartz.com\/fr\/wp-json\/wp\/v2\/tags?post=98747"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}