Site Navigation

Quartz 2mm Large Screw Neck Cuvette, 0.7ml, Molded 83, Two-way Light, Screw Cap, 1pc/ea, C022TS2

Weight 30 g
Dimensions 1.25 × 0.45 × 5.5 mm
SKU: C022TS2

USD$309.00 USD$279.00

In Stock

Quartz 2 mm screw neck cuvette, 0.7 ml, Molded 83 (>83% transmittance). Two-way Light. PTFE-Lined Screw Cap. 190–2500 nm. 1pc/ea. SKU: C022TS2.

In Stock
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist
SKU: C022TS2 Categories: , ,
Worldwide Timed Dispatch Available
  • Free Shipping apply to all orders over $1800
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Fast dispatch. Receive deliveries in 1 - 2 weeks.

Description

The C022TS2 is a quartz screw-top cuvette with 2 mm path length and two-way light optical configuration — two opposite vertical faces are polished to optical grade, forming the standard transmission geometry for UV-Vis absorbance measurements. With a 0.7 ml internal volume (10 × 2 × 54 mm chamber), the cell is compatible with most commercial spectrophotometers. Fabricated using Molded 83 (>83% transmittance) — precision-molded from a single piece of quartz, eliminating adhesive joints entirely. The PTFE-lined screw cap threads securely onto the cuvette, providing a leak-proof seal that prevents evaporation of volatile solvents and protects air-sensitive samples. The threaded closure allows safe inversion mixing and sample transport without spills.

Technical Specifications — Screw-Top Cuvette
Material Quartz (Fused Silica) SKU C022TS2
Path Length 2 mm Internal Volume 0.7 ml
Optical Windows 2 (Two-way Light) Fabrication Molded 83
Transmittance >83% Wavelength 190–2500 nm
Exterior Dimensions 12.5 × 4.5 × 55 mm Interior Dimensions 10 × 2 × 43 mm
Closure PTFE-Lined Screw Cap Package 1pc/ea

Spectroscopy Applications

UV-Vis Absorbance Spectroscopy — quantitative concentration, kinetics, Beer–Lambert studies
DNA / RNA Quantification — nucleic-acid purity checks at 260/280 nm
Protein Assays — Bradford, BCA, Lowry, and direct A280 measurements
Enzyme Kinetics — real-time substrate conversion and inhibition studies
Water Quality & Environmental — COD, nitrate, phosphate, heavy-metal colorimetric tests
Pharmaceutical QC — dissolution testing, drug concentration, stability monitoring
Chemical Reaction Monitoring — reaction progress tracking via absorbance changes
Teaching & Student Labs — durable quartz cells for undergraduate spectroscopy courses

Why Two-Way Light?

Two-way light cuvettes have two opposite polished faces that form the standard transmission path for absorbance measurements. The remaining two faces are frosted (ground), which blocks stray light from reaching the detector at oblique angles and improves measurement accuracy. This is the most common configuration for UV-Vis spectrophotometry.

Why a PTFE-Lined Screw Cap?

The internal-thread screw cap design provides the most secure closure available for standard cuvettes. Unlike friction-fit caps or stoppers, the threaded connection resists accidental opening during sample handling, vortex mixing, or transport. The PTFE liner ensures chemical inertness and a tight seal against vapour loss — critical when working with volatile organic solvents, concentrated acids, or extended kinetic measurements. The screw cap can be repeatedly removed and replaced without degradation.

Why Molded 83?

Molded 83 cuvettes are precision-molded from a single piece of quartz with no adhesive joints, achieving >83% transmittance. They withstand all common laboratory solvents, concentrated acids, and bases (avoid HF) — the most chemically resistant option available.

Usage Tips

  • Rinse with a compatible solvent (e.g., ethanol or the measurement solvent) before first use to remove any residual particles.
  • Do not use abrasive materials or brushes on the polished optical faces — wipe gently with lens tissue.
  • Withstands all common laboratory solvents, concentrated acids, and bases. Avoid HF (hydrofluoric acid).
  • Store in the original protective case to prevent scratches on the optical windows.
  • For baseline correction, fill with your reference solvent, cap the cuvette, and run a blank before sample measurements.
Custom Orders
Need a non-standard path length, volume, window configuration, or closure type? We manufacture quartz cuvettes to your exact specifications. Request a custom quote.
Disclaimer: Specifications are nominal values measured under standard laboratory conditions. Actual transmittance may vary slightly with wavelength and sample conditions. Images are representative; minor cosmetic variations between production batches are normal and do not affect optical performance.

Additional information

Weight 30 g
Dimensions 1.25 × 0.45 × 5.5 mm

Reviews

There are no reviews yet.

Be the first to review “Quartz 2mm Large Screw Neck Cuvette, 0.7ml, Molded 83, Two-way Light, Screw Cap, 1pc/ea, C022TS2”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the compare bar
Compare