Site Navigation

Quartz 20mm Large-Capacity Large-Area Optical Sample Cell, 35ml, Sintered 83, Two-way Light, No Cap, 1pc/ea, C202CR2

Weight 100 g
SKU: C202CR2

USD$128.00 USD$116.00

In Stock

Quartz 20mm large-capacity large-area optical sample cell, 35ml, Sintered 83 (>83% transmittance). Two-Way Light. Open Top (No Cap). 190–2500 nm. SKU: C202CR2.

In Stock
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist
SKU: C202CR2 Categories: , ,
Worldwide Timed Dispatch Available
  • Free Shipping apply to all orders over $1800
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Fast dispatch. Receive deliveries in 1 - 2 weeks.

Description

The C202CR2 is a quartz large-capacity large-area optical sample cell with 20mm path length and two-way light optical configuration — two opposite vertical faces are polished to optical grade, forming the standard transmission geometry for UV-Vis absorbance measurements. With a 35ml internal volume (43 × 20 × 50 mm chamber), the cell is compatible with most commercial spectrophotometers. Fabricated using Sintered 83 (>83% transmittance) — high-temperature sintered to fuse quartz panels without adhesive. Showcases an oversized rectangular cuvette body (43mm x 20mm x 50mm, 47mm wide x 52mm tall) with massive 35ml capacity, featuring the ‘Q’ marking and open-top design for large-volume optical measurements.

Technical Specifications — Large-Capacity Large-Area Optical Sample Cell
Material Quartz SKU C202CR2
Path Length 20mm Internal Volume 35ml
Optical Windows 2 (Two-Way Light) Fabrication Sintered 83
Transmittance >83% Wavelength 190–2500 nm
Exterior Dimensions 47 × 24 × 54 mm Interior Dimensions 43 × 20 × 50 mm
Closure Open Top (No Cap) Package 1pc/ea

Spectroscopy Applications

UV-Vis Absorbance Spectroscopy — quantitative concentration, kinetics, Beer–Lambert studies
DNA / RNA Quantification — nucleic-acid purity checks at 260/280 nm
Protein Assays — Bradford, BCA, Lowry, and direct A280 measurements
Enzyme Kinetics — real-time substrate conversion and inhibition studies
Water Quality & Environmental — COD, nitrate, phosphate, heavy-metal colorimetric tests
Pharmaceutical QC — dissolution testing, drug concentration, stability monitoring
Chemical Reaction Monitoring — reaction progress tracking via absorbance changes
Teaching & Student Labs — durable quartz cells for undergraduate spectroscopy courses

Why Two-Way Light?

Two-way light cuvettes have two opposite vertical faces polished to optical grade, forming the standard transmission geometry for UV-Vis absorbance measurements. The remaining two faces are frosted to minimize stray-light interference, providing clean baseline performance for quantitative spectrophotometry.

Why Open Top?

This cuvette features an open-top design without a cap or cover, providing unrestricted access to the sample chamber for easy filling, mixing, and cleaning. The open design is ideal for workflows requiring frequent sample changes, titration experiments, or when using dip probes and fiber-optic accessories that need direct access to the liquid surface.

Why Sintered 83?

Sintered 83 uses high-temperature sintering to fuse quartz panels without adhesive, delivering >83% UV transmittance from 200–2500 nm. The sintered joints are chemically inert and compatible with strong acids, bases, and most organic solvents (excluding HF and aggressive organics such as toluene and acetone). This fabrication is ideal for analytical workflows involving harsh chemical matrices where standard glued cells would degrade.

Usage Tips

  • Rinse with a compatible solvent (e.g., ethanol or the measurement solvent) before first use to remove any residual particles.
  • Do not use abrasive materials or brushes on the polished optical faces — wipe gently with lens tissue.
  • Compatible with strong acids, bases, and most organic solvents (excluding HF and aggressive organics such as toluene and acetone).
  • Store in the original protective case to prevent scratches on the optical windows.
  • For baseline correction, fill with your reference solvent, and run a blank before sample measurements.
Custom Orders
Need a non-standard path length, volume, window configuration, or closure type? We manufacture quartz cuvettes to your exact specifications. Request a custom quote.
Disclaimer: Specifications are nominal values measured under standard laboratory conditions. Actual transmittance may vary slightly with wavelength and sample conditions. Images are representative; minor cosmetic variations between production batches are normal and do not affect optical performance.

Additional information

Weight 100 g

Reviews

There are no reviews yet.

Be the first to review “Quartz 20mm Large-Capacity Large-Area Optical Sample Cell, 35ml, Sintered 83, Two-way Light, No Cap, 1pc/ea, C202CR2”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the compare bar
Compare