(MQQMC080) Glass Micro Cuvette, 10 mm Path, 1.75 mL, Two Optical Faces, Pack of 2
$42.00
Pack of two glass micro cuvettes with a 10 mm optical path, 5 mm slit and 1.75 mL nominal capacity per cell. Two opposing optical faces support visible-light transmission measurements. Open top with supplied flat lids; Standard 80 adhesive-bonded construction for room-temperature neutral aqueous samples.
Description
MQQMC080 is the 5 mm slit, 1.75 mL-per-cell option in this glass micro-cuvette series, supplied as a two-cell pack. It combines a 10 mm optical path with two opposing optical faces for transmission through the sample region. The G engraving identifies the glass configuration shown.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.75 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Visible Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 1.75 mL |
| Material | Glass |
| Closure Type | Flat Lid |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
| Sales Unit | pack of 2 cells |
| Package Contents | 2 × Glass micro cuvette; Caps and protective packaging |
Choose this option
Choose the two-face version for visible-light transmission or absorbance methods that use the 10 mm path and 5 mm slit. Match the illumination footprint to the sample-region opening rather than selecting by nominal capacity alone. This is a glass cell for visible-light work; choose the material and operating wavelength for the actual method rather than treating it as a quartz UV cell.
What makes this option different
- 10 mm optical path: the measurement distance is separate from the 5 mm slit width. These numbers describe different selection requirements.
- 5 mm sample-region slit: check the illumination footprint and optical alignment against this opening. It is the widest slit option in the stated 1–5 mm family.
- 1.75 mL nominal capacity per cell: this identifies each cuvette, rather than the combined contents of a sales pack. Establish a working fill that covers the beam without bubbles; nominal capacity is not a minimum fill-volume specification.
- Two opposing optical faces: align the transmission beam through the two intended optical faces; a frosted side surface is not an additional specified optical window.
- Two-cell sales pack: the listed price covers two separate cuvettes with the supplied lids and protective packaging. The pack is not specified as an optically matched pair.
Using this cell
Handle the rim and edges to keep fingerprints off the optical faces. Load the sample through the open top, keep bubbles away from the illuminated region and use the same seating and orientation for blank and sample. Replace the separate flat lid between handling steps to help keep dust away; it is a cover rather than a threaded or pressure-tight closure.
First-use check
- Inspect the glass body, optical faces, rim and lid for damage or residue.
- Seat the cell in the holder and confirm beam access before loading the analytical sample.
- Run a suitable blank with the same fill, seating and orientation that will be used for the sample.
Fit and optical alignment
Check the holder footprint, beam position and access to the 5 mm slit against the actual cell configuration. Leave space to lift the flat lid and introduce a pipette without contacting an optical wall. A shared 10 mm path with another cuvette does not establish that the external holder dimensions are interchangeable.
View the English selection reference.

Solvents and cleaning
Standard 80 identifies the adhesive-bonded construction used for this glass cell. Keep use to room-temperature neutral aqueous samples and choose cleaning conditions for the complete bonded assembly. Avoid organic sample solvents and organic cleaning agents on this construction.
Do not use hydrofluoric acid. Avoid hot strong alkalis, abrasive cleaning and sudden temperature changes. Rinse with an appropriate cleaning method, remove residue before taking the next blank and wipe exterior optical faces gently with non-abrasive optical tissue.
Included with this option
Two glass micro cuvettes, with the supplied flat lids and protective packaging. The price is per two-cell pack. Two cells supplied together do not constitute a stated optical-matching certificate.
Availability and ordering
Contact us to confirm current availability and dispatch timing for your quantity. For a required delivery date, check timing before checkout; preparation and production are separate from carrier transit and customs clearance.
Discuss a custom version
We can review requirements for a different path, sample region, optical access, body geometry or closure. Material, construction, feasibility and any prototype batch are confirmed for the quoted project. Send your drawing, holder details, sample conditions and quantity through the contact page, and include MQQMC080.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.