(MQQMC040) Quartz Micro Cuvette, 30 mm Path, 5.25 mL, Internal Sloping Floor
$317.00
MQQMC040 is an open-top JGS1 quartz micro cuvette with a 30 mm optical path, 5.25 mL nominal capacity and centered 5 mm side slits. Its internal twin-sloping floor distinguishes the chamber from a flat-floor cell. Standard 80 adhesive-bonded construction for room-temperature aqueous work; sold as one cell.
Description
MQQMC040 is a JGS1 quartz Micro Cuvette for UV/Vis spectroscopy with a 30 mm optical path in a compact body. The open-top format gives direct access for filling, while the centered 5 mm slit and internal twin-sloping floor define a specific sample region and measurement orientation. Supplied as one cell, it is best chosen when your holder and beam position suit this geometry rather than a general rectangular chamber.
- Path Length
- 30 mm
- Sample Volume (Nominal)
- 5.25 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 30 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 5.25 mL |
| External Dimensions | 12.5 × 32.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 32.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 32.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Micro Cuvette |
Choose this option
Choose MQQMC040 when you need a long 30 mm path in a micro cuvette body and your method is built around this slit-style sample region. The open top is straightforward for pipette filling, and the internal twin-sloping floor is part of how liquid presents in the cell, so this option is most useful when you can keep a consistent measurement orientation for blank and sample.
What makes this option different
- 30 mm optical path for UV/Vis methods that require this longer path length in a micro-format cell.
- Centered 5 mm side slits distinguish the optical-access geometry from the 30 mm measurement path.
- Internal twin-sloping floor gives the chamber its shaped lower region. It does not establish a minimum fill or complete-drainage specification.
- Open-top Two-Way Light body for direct top access and transmission through two optical faces.
Using this cell
Fill the cell from the top opening and keep the same orientation for all readings. With this slit-style geometry, the practical check is whether your actual fill level covers the illuminated region during measurement; the listed 5.25 mL is nominal capacity, not a minimum working fill. Check the liquid over the beam rather than relying on the lowest point of the shaped floor.
Before placing the cell in the instrument, inspect the sample region for bubbles, suspended particles and droplets on the outer optical faces. Handle the cuvette by the frosted sides where possible to keep the transmitting faces clean.
First-use check
- Inspect the optical faces and slit region for chips, residue or transit contamination.
- Place the cell in the holder and confirm that it seats securely in the intended orientation.
- Run a blank and verify that the filled sample region sits fully in the beam path.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The body dimensions are 32.5 × 12.5 × 45 mm. These dimensions describe the cell body only, so if your setup uses a cover, clamp or other fixture above the opening, check top clearance separately.
The 5 mm slit is not a second optical path or a guaranteed clear optical aperture. Z Height is not listed for this model. If your instrument or holder depends on a defined beam-center height, check that requirement before ordering rather than assuming fit from the outer body size alone.

Solvents and cleaning
This cuvette uses Standard 80 adhesive-bonded quartz construction. It is generally suited to room-temperature water-based samples and buffer solutions.
Avoid organic samples and organic cleaning solvents with this assembly. Keep hydrofluoric acid away from quartz, avoid hot strong alkalis, and use non-abrasive cleaning materials on the optical faces. If your method involves aggressive chemicals, elevated temperature or long soaking times, please check the exact sample and cleaning conditions with us before use.
Included with this option
1 Quartz Micro Cuvette.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving path length, body size, openings, optical windows, Z Height and other geometry details. Send your drawing or holder information, critical dimensions, sample conditions and required quantity for review.
Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation. For this SKU, you can also contact us here with your application details.
Additional information
| Weight | 60 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.