(MQQFC080) Quartz Flow Cell, 2 mm Path, 500 µL, 0.5 mm Access Holes
$288.00
JGS1 quartz flow cell with a 2 mm optical path and 500 µL nominal capacity in a slim 36 × 4 × 13.5 mm body. Two 0.5 mm access holes sit near the end regions of the broad face; this is a small-hole interface rather than projecting tube connections. Standard 80 adhesive-bonded construction for room-temperature aqueous methods; one cell supplied.
Description
MQQFC080 is a compact JGS1 quartz flow cell for UV/Vis work with a 2 mm optical path and 500 µL nominal capacity. It uses a slim body-only geometry and two end access holes on the broad face, making it a practical choice when the cell itself must fit into a narrow optical space.
This option uses two opposing optical faces transmission and an adhesive-bonded quartz construction. The drawing also identifies 0.5 mm access holes and 1 mm wall thickness, which are relevant when you are planning how the cell will be connected and supported in your assembly.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 500 µL
- Opening Configuration
- End Access Holes
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 2 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 500 µL |
| External Dimensions | 36 × 4 × 13.5 mm |
| Cell Body Dimensions | 36 × 4 × 13.5 mm |
| External Dimensions Scope | Body Only |
| Body Height | 13.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Fabrication Method | Standard 80 |
| Opening Configuration | End Access Holes |
| Port Layout | Access hole near the left end of the broad face as drawn; Access hole near the right end of the broad face as drawn |
| Wall Thickness | 1 mm |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose MQQFC080 when your method needs a short 2 mm path in a notably slim flow-cell body. It is especially useful where holder space is limited and where the access-hole layout near the ends of the broad face fits your intended fluid routing better than a top-tube or side-tube arrangement.
What makes this option different
- 2 mm optical path for short-path UV/Vis measurements in a flow-cell format.
- 36 × 4 × 13.5 mm body-only dimensions give this model a slim optical section for compact installations.
- Two end access holes are positioned near the left and right ends of the broad face as drawn.
- 0.5 mm access-hole size and 1 mm wall thickness are useful details for connection and support planning.
Using this cell
The 0.5 mm access-hole diameter is separate from the 2 mm optical path and the drawing’s local 4 mm end-region spans. The hole size alone does not identify a mating tube, thread or sealing arrangement. Plan the interface and support with your fixture rather than assuming compatibility with a standard fitting.
Plan the fluid route before installation so the two access points can be connected without stressing the cell body. Fill gradually and check the optical region for trapped bubbles before recording a blank or background.
The 500 µL value is the nominal capacity of the cell, not a stated minimum working volume. In use, make sure the beam area is fully covered under your own mounting and filling conditions.
First-use check
- Inspect the optical faces and access-hole areas for chips, residue or handling damage.
- Install the cell and verify beam position with a suitable blank.
- After filling, confirm that the optical region is free of visible bubbles and exterior droplets.
Fit and optical alignment
View the English selection reference.
The stated 36 × 4 × 13.5 mm dimensions apply to the optical body only. Check holder clearance, beam position and the extra space needed for any connected tubing or fittings separately.
Z Height is not established for this SKU, so beam-centre alignment should be checked from your holder geometry rather than assumed from the body dimensions.

Solvents and cleaning
Standard 80 is an adhesive-bonded quartz construction typically chosen for room-temperature water-based samples and buffers.
Avoid organic samples and organic cleaning solvents with this construction. If your method uses aggressive chemicals, heat or long contact time, send the liquid, concentration, temperature and contact time so the full wetted assembly can be reviewed.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
1 Quartz Flow Cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz flow-cell requirements involving path length, body size, volume, optical layout, connection details and fabrication choice. Send your holder details or a labelled drawing together with sample conditions, required quantity and target date.
Send a product-selection enquiry with SKU MQQFC080 and your installation or fluid-routing details.