Site Navigation

(MQQFL003) Quartz Flow Cell, 10 mm path, 400 µL nominal capacity, Two M6 Connections

Weight50 g
SKU: MQQFL003

$318.00

In Stock

JGS1 quartz flow cell for fluorescence setups with a 10 mm optical path, Three-Way Light access and a 400 µL nominal capacity. This version combines a 15 mm Z Height, a 4 × 10 mm window and two top M6 threaded fluid ports in a compact body. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFL003 is a JGS1 quartz flow cell for fluorescence spectroscopy with a 10 mm optical path, Three-Way Light access and two top M6 threaded fluid ports. Its 400 µL nominal capacity, 4 × 10 mm optical window and 15 mm Z Height give you a practical combination for checking beam position, connection format and sample volume together when planning a compact flow setup.

Path Length
10 mm
Sample Volume (Nominal)
400 µL
Opening Configuration
Two Threaded Fluid Ports

Selection Specifications

Product KindFlow Cell
Cell TypeFlow Cell
Measurement ModeFluorescence Spectroscopy
Path Length10 mm
Light Transmission ConfigurationThree-Way Light
Z Height15 mm
Optical Window Dimensions4 × 10 mm
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)400 µL
External Dimensions12.5 × 12.5 × 40 mm
Body Height40 mm
Base Dimensions12.5 × 12.5 mm
MaterialQuartz
Material GradeJGS1
Port Count2
Port ThreadM6
Fabrication MethodStandard 80
Opening ConfigurationTwo Threaded Fluid Ports
Port LayoutTop connection at the left in the referenced original; Top connection at the right in the referenced original
Pack Quantity1 Piece
Package Contents1 × Quartz Flow Cell

Choose this option

Choose this cell when your setup needs a defined 15 mm beam-center height and threaded top connections rather than plain tube ends. The 10 mm path and Three-Way Light layout suit fluorescence arrangements that need the main measurement path plus side optical access around the sample region, while the compact 12.5 × 12.5 × 40 mm body helps when holder space is limited.

What makes this option different

  • Three-Way Light layout adds side optical access around the 10 mm measurement path.
  • Two top M6 threaded fluid ports let you match the cell to threaded fittings and upward tubing runs.
  • 15 mm Z Height gives a defined beam-center reference from the cell bottom to the optical axis.
  • 400 µL nominal capacity with a 4 × 10 mm window balances flow-cell volume with a clearly specified optical region.

Using this cell

Support the cell body independently when installing it, rather than letting tubing or fittings carry the load. Fill the cell gradually and check the optical region for trapped bubbles before taking a blank or sample reading.

The 400 µL figure is the nominal cell capacity. It is not a stated minimum working volume, and it does not include the liquid volume in external tubing or fittings. Keep the same installed orientation between blank and sample measurements so the optical geometry remains consistent.

First-use check

  1. Inspect the window faces and threaded connection areas before installation.
  2. Check holder fit, beam height and fitting clearance before connecting the final fluid circuit.
  3. Fill slowly, remove visible bubbles from the optical region, and repeat the blank in the installed position.

Fit and optical alignment

View the English selection reference.
View the English dimensional reference.

Use the 15 mm Z Height to compare the instrument beam position with the cell axis, and check the 4 × 10 mm window against your beam footprint. The body is 12.5 × 12.5 × 40 mm, but you should also allow clearance above the cell for the two top M6 connections and the fittings you plan to install.

Pressure limits are not stated for this SKU, so do not set operating conditions from the threaded ports alone. Review the complete assembled fluid path before using the cell in a pressurized system.

English selection reference
Selection reference ↗

Solvents and cleaning

Standard 80 indicates an adhesive-bonded quartz construction. This style is generally chosen for routine room-temperature aqueous samples and buffers. Avoid organic samples and organic cleaning solvents with this cell.

Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials. Clean the optical faces gently, and choose a cleaning routine that is suitable for the full bonded assembly as well as the quartz body.

Included with this option

1 Quartz Flow Cell.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz flow cells for changes to path length, window size, Z Height, body dimensions and connection format. Use this contact page to send your drawing or fixture details, sample conditions, quantity and required delivery destination.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFL003) Quartz Flow Cell, 10 mm path, 400 µL nominal capacity, Two M6 Connections”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare