(MQQFL003) Quartz Flow Cell, 10 mm path, 400 µL nominal capacity, Two M6 Connections
Description
MQQFL003 is a JGS1 quartz flow cell for fluorescence spectroscopy with a 10 mm optical path, Three-Way Light access and two top M6 threaded fluid ports. Its 400 µL nominal capacity, 4 × 10 mm optical window and 15 mm Z Height give you a practical combination for checking beam position, connection format and sample volume together when planning a compact flow setup.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 400 µL
- Opening Configuration
- Two Threaded Fluid Ports
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Three-Way Light |
| Z Height | 15 mm |
| Optical Window Dimensions | 4 × 10 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 400 µL |
| External Dimensions | 12.5 × 12.5 × 40 mm |
| Body Height | 40 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Port Thread | M6 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Two Threaded Fluid Ports |
| Port Layout | Top connection at the left in the referenced original; Top connection at the right in the referenced original |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose this cell when your setup needs a defined 15 mm beam-center height and threaded top connections rather than plain tube ends. The 10 mm path and Three-Way Light layout suit fluorescence arrangements that need the main measurement path plus side optical access around the sample region, while the compact 12.5 × 12.5 × 40 mm body helps when holder space is limited.
What makes this option different
- Three-Way Light layout adds side optical access around the 10 mm measurement path.
- Two top M6 threaded fluid ports let you match the cell to threaded fittings and upward tubing runs.
- 15 mm Z Height gives a defined beam-center reference from the cell bottom to the optical axis.
- 400 µL nominal capacity with a 4 × 10 mm window balances flow-cell volume with a clearly specified optical region.
Using this cell
Support the cell body independently when installing it, rather than letting tubing or fittings carry the load. Fill the cell gradually and check the optical region for trapped bubbles before taking a blank or sample reading.
The 400 µL figure is the nominal cell capacity. It is not a stated minimum working volume, and it does not include the liquid volume in external tubing or fittings. Keep the same installed orientation between blank and sample measurements so the optical geometry remains consistent.
First-use check
- Inspect the window faces and threaded connection areas before installation.
- Check holder fit, beam height and fitting clearance before connecting the final fluid circuit.
- Fill slowly, remove visible bubbles from the optical region, and repeat the blank in the installed position.
Fit and optical alignment
View the English selection reference.
View the English dimensional reference.
Use the 15 mm Z Height to compare the instrument beam position with the cell axis, and check the 4 × 10 mm window against your beam footprint. The body is 12.5 × 12.5 × 40 mm, but you should also allow clearance above the cell for the two top M6 connections and the fittings you plan to install.
Pressure limits are not stated for this SKU, so do not set operating conditions from the threaded ports alone. Review the complete assembled fluid path before using the cell in a pressurized system.

Solvents and cleaning
Standard 80 indicates an adhesive-bonded quartz construction. This style is generally chosen for routine room-temperature aqueous samples and buffers. Avoid organic samples and organic cleaning solvents with this cell.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials. Clean the optical faces gently, and choose a cleaning routine that is suitable for the full bonded assembly as well as the quartz body.
Included with this option
1 Quartz Flow Cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz flow cells for changes to path length, window size, Z Height, body dimensions and connection format. Use this contact page to send your drawing or fixture details, sample conditions, quantity and required delivery destination.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.









Reviews
There are no reviews yet.