(MQQIR001) Quartz Standard Cuvette, 20 mm path, 7 mL nominal capacity, JGS3 Infrared Cell
Description
MQQIR001 is a JGS3 quartz Standard Cuvette for infrared transmission work with a 20 mm optical path and 7 mL nominal capacity. Its open-top body lets you load liquid directly from above, and the supplied flat lid covers the opening after filling. This option is useful when you need a straightforward IR cell that combines top access, a longer transmission path and a holder-sized rectangular body.
- Path Length
- 20 mm
- Sample Volume (Nominal)
- 7 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | Infrared Spectroscopy |
| Path Length | 20 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 260 nm |
| Sample Volume (Nominal) | 7 mL |
| External Dimensions | 22.5 × 12.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 22.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS3 |
| Closure Type | Flat Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Standard Cuvette; Accompanying closure |
Choose this option
Choose MQQIR001 when your method needs a 20 mm transmission path in a quartz cell intended for infrared spectroscopy, and when routine top filling matters in daily use. The open top is practical for pipetting, rinsing and visual checking during loading, while the flat lid lets you cover the filled cell without changing to a different assembly. Its 7 mL nominal capacity and rectangular 22.5 × 12.5 mm base are also relevant when you are matching both sample amount and holder space.
What makes this option different
- Open top with flat lid gives direct access to the sample chamber for filling and inspection, then lets you cover the opening for the measurement setup.
- 20 mm optical path suits transmission methods built around a longer liquid path than short-path routine cells, so path length should be selected to match your method rather than treated as a general replacement size.
- 7 mL nominal capacity indicates a full cell volume appropriate to this body format; it helps you plan sample preparation, but it is not a minimum working volume.
- Two-Way Light geometry supports transmission through the intended optical direction of the cell, so the holder and beam should align with that path.
- Fused-integrated construction means the cell body is supplied as a joined finished assembly rather than as a demountable plate-and-spacer style cell, which suits routine fill, cover and measure handling.
- 22.5 × 12.5 × 45 mm body size is important when checking holder clearance, clamp seating and chamber space in instruments that use fixed cuvette holders.
Using this cell
Fill the cell from the top and place the flat lid after loading. This arrangement is convenient when you want direct access during pipetting or rinsing, but still want the opening covered once the sample is in place.
Use a consistent orientation for blank and sample runs. The stated 7 mL is the nominal capacity of the cell, not a working-fill guarantee, so make sure the liquid level covers the beam region used by your instrument.
First-use check
- Inspect the chamber, optical faces and lid for chips, residue or handling marks.
- Place the empty cell in your holder and confirm stable seating and clearance before filling.
- Run a background or blank in the same orientation you plan to use for sample measurements.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
Check the 22.5 × 12.5 mm base and 45 mm body height against your holder, clamp and instrument chamber before ordering. The cell is a transmission format with Two-Way Light access, so it should be seated in the orientation that matches your instrument beam.
Z Height is not established for this exact SKU. If your instrument uses a fixed beam height or has limited vertical adjustment, verify beam position against the sample region before purchase.

Solvents and cleaning
The reviewed evidence does not establish a full chemical compatibility range for this exact assembly. If your method involves specific solvents, concentration, temperature or long contact time, check suitability before use.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning materials. Clean the optical faces gently with suitable non-abrasive laboratory wipes.
Compare fabrication options if your application needs a different construction approach for sample chemistry, cleaning routine or tolerance requirements.
Included with this option
1 quartz cuvette and an accompanying closure.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, body size, closure style or other geometry, send your holder details or a labeled drawing through the contact page. Custom projects are reviewed case by case for feasibility, specification, quantity, price and production time.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.