(MQQCM001) Fused-Integrated Quartz Colorimetric Cuvette, 10 mm Path, 13 mL

Weight50 g
SKU: MQQCM001

$252.00

In Stock

Fused-integrated JGS1 quartz colorimetric cuvette with a 10 mm optical path and 13 mL nominal capacity. Two opposing optical faces provide straight-through transmission; the open top gives direct access for filling and rinsing. Body size: 31 × 14 × 62 mm. One cell supplied.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQCM001 is a JGS1 quartz colorimetric cuvette with a 10 mm optical path, Two-Way Light transmission and a 13 mL nominal capacity for UV/Vis spectroscopy. Its open-top chamber provides direct filling access, with listed internal dimensions of 27 × 10 × 60 mm.

The external size is 31 × 14 × 62 mm, and the cell is sold as one piece. This cell uses the supplier-described fused-integrated construction.

Path Length
10 mm
Sample Volume (Nominal)
13 mL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeColorimetric Cuvette
Measurement ModeUV/Vis Spectroscopy
Path Length10 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)13 mL
External Dimensions31 × 14 × 62 mm
Body Height62 mm
Base Dimensions31 × 14 mm
Internal Dimensions27 × 10 × 60 mm
MaterialQuartz
Material GradeJGS1
Opening ConfigurationOpen Top
Pack Quantity1 Piece
Package Contents1 × Quartz Colorimetric Cuvette

Choose this option

Choose MQQCM001 when your method uses a 10 mm path and you need a larger open quartz chamber for direct filling, rinsing or visual inspection. Match the 31 × 14 mm footprint and 62 mm height to your holder, leaving room above the open chamber for sample handling.

What makes this option different

  • 10 mm optical path for standard UV/Vis transmission work.
  • Two-Way Light transmission: align the opposing optical faces with the beam and keep the same orientation for blank and sample.
  • 13 mL nominal capacity with a larger chamber for methods that use more sample volume.
  • Open-top chamber for direct filling, emptying and visual access to the sample region.
  • 31 × 14 × 62 mm external size with 27 × 10 × 60 mm internal dimensions for setups that need a larger body and chamber.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Fill from the open top and keep the same optical direction for blank and sample measurements. Before reading, make sure the liquid level covers the illuminated region in your instrument and remove visible bubbles from the optical path.

The open-top chamber gives direct access for pipetting, pouring and rinsing. If your method needs covered operation, splash control or evaporation management, check the closure arrangement and working clearance for your setup.

First-use check

  1. Inspect the optical faces and chamber edges for residue or handling damage before first use.
  2. Test holder fit and beam position with a suitable blank before running samples.
  3. After filling, remove bubbles and wipe the outside optical faces dry before measurement.

Fit and optical alignment

View the English selection reference. Also available in the product gallery.

Check the 31 × 14 × 62 mm external size against your holder slot and surrounding clearance before ordering. The optical path is 10 mm, but Z Height is not available in the current evidence, so instruments with a fixed beam-height requirement should be checked against your current cell or holder details before purchase.

English selection reference
Selection reference ↗

Solvents and cleaning

This option is identified as fused-integrated quartz construction, but no fabrication grade is established here. Use a cleaning and sample routine suitable for quartz, and if your method involves aggressive chemicals, organic solvents, elevated temperature or long soaking times, please check suitability before ordering.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaners. Rinse promptly after use and clean the optical faces gently with non-abrasive optical tissue.

Included with this option

1 MQQCM001 cuvette. The listed price is for one cell.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for requirements involving path length, chamber size, external envelope, openings and tolerances. If you need this chamber style in a different body size or for a holder with defined beam geometry, send a drawing or labelled sketch with the critical dimensions.

Send a product-selection enquiry with SKU MQQCM001, your holder or existing cell details, sample conditions, quantity and delivery destination.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQCM001) Fused-Integrated Quartz Colorimetric Cuvette, 10 mm Path, 13 mL”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare