(MQQST001) Quartz Stoppered Cuvette, 3 mm path, 1.05 mL nominal capacity, Narrow Stoppered Sample Chamber
$281.00
MQQST001 is a JGS1 quartz stoppered cuvette for UV/Vis spectroscopy with a 3 mm optical path, Two-Way Light layout and 1.05 mL nominal capacity. Its narrow stoppered chamber format suits methods that need top access followed by fitted closure in a compact body. Supplied as one cell with an accompanying stopper.
Description
MQQST001 is a JGS1 quartz stoppered cuvette for UV/Vis spectroscopy with a 3 mm optical path, Two-Way Light configuration and 1.05 mL nominal capacity. The narrow 12.5 × 5.5 mm footprint combines short-path measurement with a neck opening for filling and a fitted stopper. The cell body is 35 mm high; the neck extends the uncapped height to 45 mm. This listed sale unit is 1 piece.
- Path Length
- 3 mm
- Sample Volume (Nominal)
- 1.05 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Stoppered Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 3 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.05 mL |
| Cell Body Dimensions | 12.5 × 5.5 × 35 mm |
| Overall Height without Closure | 45 mm |
| Body Height | 35 mm |
| Base Dimensions | 12.5 × 5.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Stoppered Cuvette |
Choose this option
Choose MQQST001 when your method uses a 3 mm transmission path and a stoppered sample chamber rather than an open-top cell. The 1.05 mL nominal capacity gives a practical guide to the chamber size, while the compact 12.5 × 5.5 mm base and 35 mm body height help when you need to check holder fit and clearance around the top opening.
What makes this option different
- Stopper closure format for filling from the top and then closing the sample chamber for handling and measurement.
- 3 mm optical path for UV/Vis methods set up for a shorter transmission length.
- Two-Way Light layout for transmission through opposing optical faces in one optical direction.
- 1.05 mL nominal capacity to help you plan filling volume for this chamber format.
- 12.5 × 5.5 mm base and 35 mm body height for checking holder footprint and vertical clearance.
- Integrated-forming construction with Molded 83 fabrication terminology for this option.
Using this cell
Fill the chamber from the top, then seat the stopper for your measurement routine if your method uses the closed configuration. Support the cell by its body rather than lifting it by the stopper. A fitted stopper covers the opening; no leak-tightness or pressure rating is specified. Keep the same orientation for blank and sample measurements, and remove visible bubbles before placing the cuvette in the beam.
The 1.05 mL value is the nominal capacity of the chamber, not a stated minimum working volume. If your method uses a low fill level, check that the filled sample still covers the illuminated region in your instrument.
First-use check
- Inspect the optical faces and chamber for chips, residue or handling marks.
- Test the fit in your holder before preparing a critical sample.
- Run a blank in the intended orientation and confirm that the filled sample covers the illuminated region.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
Check the holder slot and bottom support against the 12.5 × 5.5 mm base and 35 mm cell-body height. Allow 45 mm to the uncapped neck top, plus the space needed for a stopper and its removal. A height with a fitted stopper is not specified. The optical path is known, but Z Height is not stated for this option, so beam-height-sensitive instruments should be checked against your current cell or holder drawing before ordering.
If you are replacing an existing cuvette in a fixed holder, send the holder drawing or the dimensions of the cell you currently use so the fit can be reviewed before purchase.

Solvents and cleaning
Molded 83 is generally chosen for methods that may involve organic solvents or elevated-temperature use, but suitability still depends on the complete assembly and your actual conditions. This is a stoppered cell, so sample and cleaning compatibility should be considered for the full wetted setup rather than the quartz body alone when conditions are demanding.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning materials. Clean the optical faces gently with a non-abrasive tissue or other suitable lint-free material.
Included with this option
1 Quartz Stoppered Cuvette (MQQST001) with one accompanying stopper. The listed price is for one cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We also coordinate custom JGS1 quartz cuvette enquiries when you need a different path length, volume, outer dimensions, closure style or other modified geometry. Prototype batches typically involve 2–4 cells, with feasibility, final specification, quantity, price and production time confirmed for the project.
Send a product-selection enquiry with SKU MQQST001 and your drawing, holder details or application notes if you need a modified version.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.