(MQQST002) Quartz Stoppered Cuvette, 3 mm path, 1.05 mL nominal capacity, Narrow Stoppered Sample Chamber, Pack of 2
$562.00
MQQST002 is a JGS1 quartz stoppered cuvette for UV/Vis spectroscopy with a 3 mm optical path, Two-Way Light layout and 1.05 mL nominal capacity. Its narrow stoppered chamber format suits methods that need top filling followed by fitted closure in a compact body. The listed sale unit is a pack of 2 cuvettes with accompanying closures.
Description
MQQST002 is a JGS1 quartz stoppered cuvette for UV/Vis spectroscopy with a 3 mm optical path, Two-Way Light configuration and 1.05 mL nominal capacity. It is a useful choice when your method needs a stoppered sample chamber rather than an open-top cell, and when the holder space around the body and top access is limited. The listed sale unit is a pack of 2 cuvettes with accompanying closures.
- Path Length
- 3 mm
- Sample Volume (Nominal)
- 1.05 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Stoppered Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 3 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.05 mL |
| Cell Body Dimensions | 12.5 × 5.5 × 35 mm |
| Overall Height without Closure | 45 mm |
| Body Height | 35 mm |
| Base Dimensions | 12.5 × 5.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Sales Unit | pack of 2 |
| Package Contents | 2 × Quartz Stoppered Cuvette; Accompanying closures |
Choose this option
Choose MQQST002 when your method uses a 3 mm transmission path and you want a stoppered quartz cell for top filling followed by closed handling. The 1.05 mL nominal capacity helps you plan sample preparation for this chamber size, while the 12.5 × 5.5 mm base and 35 mm body height are useful when you need to check a compact holder layout before ordering.
What makes this option different
- Stopper closure format for loading from the top and then closing the chamber for routine handling and measurement.
- 3 mm optical path for UV/Vis methods that use a shorter transmission length.
- Two-Way Light layout for transmission through opposing optical faces in one optical direction.
- 1.05 mL nominal capacity to guide filling for this chamber format.
- 12.5 × 5.5 mm base and 35 mm body height for checking holder footprint and vertical clearance.
- Integrated-forming construction with Molded 83 fabrication terminology for this option.
- Pack of 2 cuvettes with accompanying closures in the selected sale unit.
Using this cell
Fill the cuvette from the top so the liquid covers the illuminated region, then seat the stopper for your measurement routine. Keep the same orientation for blank and sample runs, and remove visible bubbles before placing the cuvette in the holder.
The 1.05 mL figure is a nominal chamber capacity, not a stated minimum working volume. If your method runs close to a low fill level, check the beam position in your instrument before routine use.
First-use check
- Inspect the optical faces and chamber for chips, residue or transport marks before use.
- Test holder fit and beam alignment with a suitable blank in the measurement position you will use.
- After filling, remove bubbles and wipe the exterior optical faces before running the blank and sample sequence.
Fit and optical alignment
View the English selection reference. The product gallery also shows the cell format for planning holder fit and sample access.
The body height is 35 mm, with a 12.5 × 5.5 mm base footprint. These dimensions are useful for checking holder width, depth and vertical clearance, especially where the stopper and loading space above the cell matter. Z Height is not specified for this option, so beam-center fit should be checked against your instrument or existing cell before ordering for beam-sensitive setups.

Solvents and cleaning
This cuvette is listed as Molded 83. For solvent suitability, consider the complete wetted assembly, including the stopper, rather than the quartz body alone. If your method uses aggressive chemicals, elevated temperature or long contact time, check the exact sample and cleaning conditions before ordering.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with a non-abrasive tissue or other suitable laboratory wiping material.
Included with this option
Supplied as 2 MQQST002 quartz stoppered cuvettes with accompanying closures. The listed price is for the pack of 2.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes involving path length, body dimensions, sample capacity, closure style and other installation-related details. If you need a different fit, send your holder drawing or existing cell reference together with the critical dimensions, sample conditions and required quantity.
Send a product-selection enquiry with SKU MQQST002 and your application details.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.













Reviews
There are no reviews yet.