Quartz 1mm Standard Cuvette, 350ul, Molded 0.01, Two-way Light, Closure Included, C012CF1
Original price was: $190.00.$171.00Current price is: $171.00.
C012CF1 is a JGS1 quartz standard cuvette with a 1 mm optical path, Two-Way Light layout and 350 µL nominal capacity. Its open-top body gives direct access for filling, and a closure is included for the selected cell. Sold as C012CF1 in the current selected specification.
Description
C012CF1 is a JGS1 quartz standard cuvette for methods that need a short 1 mm optical path in a slim rectangular cell. It combines a Two-Way Light layout with a 350 µL nominal capacity and an open-top body, so you can fill the sample directly and then place the included closure as needed for your handling routine. The uncapped cell body is 12.5 × 3.5 × 45 mm, which is useful to check where holder width or top clearance is limited.
Choose this option
Choose C012CF1 when your method needs a 1 mm transmission path in quartz and you want direct top access to the sample chamber rather than a permanently closed or threaded format. The 350 µL nominal capacity suits small prepared volumes, while the included closure supports covered handling after filling. This option uses Molded 0.01 fabrication, which is the relevant version to review when your sample and cleaning routine call for this specific fabrication choice.
What makes this option different
- 1 mm optical path for short-path transmission measurements in a standard cuvette form.
- Two-Way Light layout for a beam passing through two opposing optical faces.
- Open-top cell body for direct filling and visual access to the sample chamber before placing the closure.
- 350 µL nominal capacity, useful when your prepared sample volume is limited but you still need a full standard-cell body format.
- Molded 0.01 fabrication, often chosen when the project calls for this fabrication type rather than an adhesive-bonded option; sample and cleaning liquids should still be reviewed for the full assembled cell.
- Uncapped body dimensions of 12.5 × 3.5 × 45 mm for checking holder width and top-side clearance separately from the closure.
Using this cell
Fill the sample through the open top and place the closure after loading if your handling method calls for the cell to be covered. Handle the cuvette by the non-optical sides and keep the optical faces clean before measurement.
The stated 350 µL figure is the nominal capacity of this cell. It is not a minimum working volume, and no minimum fill height is established here, so methods that depend on a specific beam height or very tight fill margin should be checked against the instrument setup.
First-use check
- Inspect the optical faces and rim for chips, residue or handling marks.
- Test-fit the uncapped cell body in your holder without forcing it.
- Rinse with a suitable process liquid, then dry or condition the cell according to your method before use.
Fit and optical alignment
This cuvette has a slim rectangular body with uncapped dimensions of 12.5 × 3.5 × 45 mm. Check the holder slot and the available clearance above the cell, because the listed height applies to the bare body and does not include the closure.
Z Height is not established for this SKU. If your instrument or holder requires a specific beam-center height, confirm that requirement before ordering rather than assuming fit from the general cell shape.
Solvents and cleaning
For a method with a defined optical path tolerance, specify that tolerance and its measurement conditions when selecting the Molded 0.01 option. The final requirement is agreed for the order.
C012CF1 is a JGS1 quartz cuvette with Molded 0.01 fabrication. For customer selection, that means the fabrication type is part of this exact SKU choice and should be considered together with your sample chemistry and your cleaning routine, especially if you are comparing it with other fabrication options for the same general cell style.
Specific chemical limits for this exact SKU are not established here. Review the full sample-contact and cleaning conditions for the assembled cell, including the closure used in your process. Do not use hydrofluoric acid with quartz, and avoid hot strong alkalis or abrasive cleaning methods.
Included with this option
Supplied as C012CF1 with a closure included. Other package contents and the exact sale quantity are not specified here.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a related quartz cuvette with a different path length, body size, nominal volume or closure arrangement, send a drawing or labelled sketch with the dimensions that matter to your setup. If holder fit or beam position is important, include your instrument or accessory details so the geometry can be reviewed before quotation.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.