(C104CE7) Quartz Micro Cuvette, 10 mm / 3 mm (dual path) Path, 1.05 mL, Pack of 2
Original price was: $646.00.$582.00Current price is: $582.00.
C104CE7 is a JGS1 quartz micro cuvette for fluorescence measurements with a 10 mm main path, a 3 mm secondary path and Four-Way Light access. Its nominal capacity is 1.05 mL, and this sale option is supplied as a pack of 2 cuvettes with closure included.
Description
C104CE7 is a JGS1 quartz micro cuvette for fluorescence work that combines a 10 mm main optical path with a 3 mm secondary path in the same compact cell format. Four-Way Light access and a 3 mm sample-region width make it suitable for methods that use a defined multi-direction optical layout rather than a simple single-path cuvette. This option is sold as a pack of 2 cuvettes, with closure included.
- Path Length
- 10 mm / 3 mm (dual path)
- Sample Volume (Nominal)
- 1.05 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 10 mm / 3 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 3 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.05 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Detection Channel Width | 3 mm |
Choose this option
Choose C104CE7 when you need the stated dual-path micro cuvette geometry and want two cuvettes in the sale unit. The 10 mm and 3 mm optical paths give you two defined optical directions in one cell, while the 1.05 mL nominal capacity and compact body format suit routine fluorescence work where holder size and handling matter alongside the optical layout.
What makes this option different
- Dual optical path with a 10 mm main path and 3 mm secondary path.
- Four-Way Light layout for optical access from multiple sides.
- 1.05 mL nominal capacity with a 3 mm sample-region width.
- 12.5 × 12.5 × 45 mm uncapped cell body for holder and clearance checks.
- Pack of 2 cuvettes with closure included for this sale unit.
Using this cell
Fill the cell so the illuminated region is fully covered during measurement, and keep bubbles, droplets and residue away from the optical faces. If your method relies on the dual-path geometry, keep blank and sample in the same orientation so the beam continues to pass through the intended region.
The stated 1.05 mL is the nominal capacity of each cell, not a minimum working volume. Set the practical fill level according to your beam position, sample behavior and measurement orientation.
First-use check
- Inspect both cuvettes and their optical faces for chips, marks or residue.
- Test each cell in the holder before preparing samples.
- Run a blank and confirm the intended orientation, clearance and beam position.
Fit and optical alignment
The confirmed 12.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body. Use them to review holder seating and compartment space, but leave additional room if your setup includes the fitted closure because the full capped envelope is not established here.
Z Height is not established for this option. If your instrument or holder depends on a fixed beam-center height, check alignment against your actual setup rather than assuming direct compatibility from the body dimensions or the 3 mm sample-region width.
Solvents and cleaning
This cuvette uses Molded 83 fabrication. This construction is commonly selected for methods that may involve organic solvents or temperature-controlled work, but suitability still depends on the complete assembled cell and your actual chemical conditions.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive optical tissue and use a cleaning routine that also suits the included closure.
Included with this option
2 cuvettes per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz cuvettes for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication. Send a dimensioned drawing or labelled sketch together with your holder information, critical dimensions, sample conditions and target quantity. Modified versions and prototype batches are quoted separately from the listed SKU. Discuss your requirements and quote C104CE7.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.