(C104CR28) Quartz Micro Cuvette, 10 mm Path, 700 µL
Original price was: $138.00.$125.00Current price is: $125.00.
C104CR28 is a quartz micro cuvette with a 10 mm optical path, Four-Way Light access and 700 µL nominal capacity for fluorescence spectroscopy. This option combines an open-top body with a 2 mm sample-region channel, which is useful when your method needs direct top filling and a narrower illuminated sample region within a compact square cuvette format. Supplied as 1 cuvette per price unit, with a closure included.
Description
C104CR28 is a quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path in a compact 12.5 × 12.5 mm body format. Its Four-Way Light layout gives optical access from the sides as well as along the main path, while the open top makes filling and inspection straightforward. The 700 µL nominal capacity and 2 mm sample-region channel make this option useful when you want a narrower sample presentation than wider-channel versions in the same general format.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 700 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top (Cell Body) |
| Detection Channel Width | 2 mm |
Choose this option
Choose C104CR28 when you need a square micro cuvette with direct top access, a 10 mm path and side optical access for fluorescence work. The 2 mm sample-region channel is the detail to check if your method depends on how the sample sits in the illuminated region, and the 700 µL nominal capacity suits this specific narrow-channel body without moving up to a larger cuvette format.
What makes this option different
- 10 mm optical path in a quartz micro cuvette body.
- Four-Way Light configuration for optical access from four sides.
- Open-top cell body for direct filling, viewing and cleaning access from above.
- 700 µL nominal capacity matched to this compact micro-cuvette format.
- 2 mm sample-region channel for a narrower sample presentation in the beam region.
- Uncapped body dimensions of 12.5 × 12.5 × 45 mm for holder and clearance checks.
- Supplied as 1 cuvette per price unit, with a closure included.
Using this cell
Fill the cell from the top opening and add the included closure after loading the sample. During use, keep the optical faces and the top edge clean and free from droplets so the beam passes through a clear, fully covered liquid region.
The 700 µL figure is the nominal capacity of the cell, not a minimum working volume. If you plan to use less than a full fill, check the liquid level in your own holder and measurement position rather than assuming beam coverage from the nominal capacity alone.
The supplier describes this version as a powder-fused construction research type. In practical use, that makes the top opening and cleaning method more important than a simple grade label: load carefully, avoid chipping the opening, and choose cleaning steps that suit a precision quartz laboratory cell rather than abrasive general glassware handling.
First-use check
Before first use, inspect the cuvette for chips, dust, fingerprints or residue on the optical faces and around the opening. Run a blank in the intended orientation to confirm stable seating, practical fill level and clean optical alignment in your own instrument.
Fit and optical alignment
The listed 12.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body. Use those dimensions to check holder fit, seating depth and side clearance, but leave extra vertical space for the included closure because the overall closed height is not listed here.
Z Height is not listed for this SKU. If your instrument depends on a defined beam-center height, verify that with your holder and beam position before purchase. The 2 mm sample-region channel should also be checked against your beam footprint so the illuminated area sits where you expect inside the sample region.
Solvents and cleaning
This quartz micro cuvette is intended for fluorescence work and uses a powder-fused construction style in an open-top research format. That combination is well suited to routine laboratory handling where you need direct access for filling and rinsing, but it is still important to match the sample and cleaning method to the complete wetted assembly rather than assuming unrestricted chemical use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue. For background on MQ cuvette fabrication types, see https://machinedquartz.com/fabrication-method-of-cuvettes/.
Included with this option
Supplied as 1 micro cuvette with a lid and box.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to dimensions, optical path length, sample volume, optical windows, Z Height, closures and related geometry. Send a dimensioned drawing or labelled sketch together with holder details, sample chemistry and target quantity. Discuss your requirements and quote part number C104CR28.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.