(C104SR18) Quartz Micro Cuvette, 10 mm Path, 700 µL
Original price was: $293.00.$264.00Current price is: $264.00.
C104SR18 is a quartz micro cuvette with a 10 mm optical path, Four-Way Light geometry and a stoppered neck for covered sample handling. This version combines a 700 µL nominal capacity with a 2 mm sample-region width for fluorescence work that needs a wider measurement region than the 1 mm option. Supplied as 1 quartz cuvette with stopper.
Description
C104SR18 is a quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path, four optical sides and a stoppered neck. This version pairs a 700 µL nominal capacity with a 2 mm sample-region width, giving you a covered micro cell with more sample width than the narrowest variant in the same style. The included stopper makes it suitable for routine handling where you want the sample covered between filling and measurement.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 700 µL
- Opening Configuration
- Stoppered Neck
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 2 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| Material | Quartz |
| Closure Type | Stopper |
| Closure Included | Yes |
| Opening Configuration | Stoppered Neck |
| Detection Channel Width | 2 mm |
Choose this option
Choose C104SR18 when you need a 10 mm path in a stoppered micro cuvette and want a 2 mm sample region rather than the narrower 1 mm format. The Four-Way Light layout suits fluorescence setups with compatible beam geometry, and the 700 µL nominal capacity places this version between the smaller and larger stoppered options in the group. It is a useful selection when you want a moderate nominal volume without moving to the widest sample region.
What makes this option different
- 10 mm optical path for methods built around that path length.
- Four-Way Light geometry supports fluorescence measurements with side optical access.
- 2 mm sample-region width gives a wider measurement region than the 1 mm version.
- 700 µL nominal capacity offers a mid-range volume within these related stoppered micro cuvettes.
- Stoppered neck with stopper included for covered handling.
Using this cell
Fill the cuvette through the neck, then seat the stopper gently before placing it in the holder. During use, keep the optical faces free from fingerprints, droplets and dried film, and make sure the beam passes through a fully covered liquid region.
Use a consistent orientation for blank and sample runs. The 700 µL figure is the nominal cuvette capacity, not a minimum working volume or fill recommendation.
First-use check
Inspect the windows and neck area before first use, rinse with a method-suitable liquid, and confirm that the cuvette sits squarely in the holder. Run a blank at your working wavelength and verify that the filled sample region fully covers the beam in the chosen orientation.
Fit and optical alignment
Although the path length is 10 mm, instrument fit should still be checked for your holder and beam position. Z Height is not listed for this option, so compatibility with a specific fluorescence holder or micro-cell adapter should not be assumed from the family name alone.
The 2 mm sample-region width is part of the optical layout and should be considered together with your beam footprint. This matters most when your instrument uses a dedicated micro-cell holder or a tightly defined beam path.
Solvents and cleaning
This quartz cuvette is listed for use from 200 to 2500 nm. For general construction background, see Compare fabrication methods.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Detailed chemical limits for this exact SKU are not established here, so check sample and cleaning conditions before using aggressive solvents or extended contact times.
Included with this option
This option includes one quartz micro cuvette and its stopper.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions for changes to dimensions, path length, sample volume, optical windows, Z Height, closures or tolerances. Send your drawing or labelled sketch, holder or instrument details, sample conditions and target quantity through Discuss your requirements, and refer to part number C104SR18.