Site Navigation

(MQQLW004) JGS1 Quartz Large-Window Cuvette, 3 mm Path, 1.9 mL

Weight50 g
SKU: MQQLW004

$359.00

In Stock

MQQLW004 is a JGS1 quartz large-window cuvette with a 3 mm optical path, Two-Way Light layout and 1.9 mL nominal capacity for UV/Vis spectroscopy. Its open-top 24 × 5.5 × 40 mm body suits holders designed for a broad, slim cuvette shape rather than a standard square cell. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQLW004 is a JGS1 quartz large-window cuvette for UV/Vis spectroscopy with a 3 mm optical path and 1.9 mL nominal capacity. Its broad, slim body gives you a different fit from a square cuvette, so it is useful when your holder and beam layout are built around this cell shape. The open top keeps filling and visual checking straightforward at the bench.

View the English selection reference.

Path Length
3 mm
Sample Volume (Nominal)
1.9 mL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeLarge-Window Cuvette
Measurement ModeUV/Vis Spectroscopy
Path Length3 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)1.9 mL
External Dimensions24 × 5.5 × 40 mm
Cell Body Dimensions24 × 5.5 × 40 mm
External Dimensions ScopeBody Only
Body Height40 mm
MaterialQuartz
Material GradeJGS1
MQ GradeMolded 83
Fabrication MethodMolded 83
Opening ConfigurationOpen Top
Pack Quantity1 Piece

Choose this option

Choose MQQLW004 when your method uses a 3 mm path and your holder accepts a broad, slim large-window body. The 1.9 mL nominal capacity is suited to routine liquid loading, while the open-top format keeps manual filling, rinsing and visual inspection simple.

What makes this option different

  • 3 mm optical path for methods specified around a shorter absorbance path.
  • Large-window, Two-Way Light body for transmission through the stated optical direction in a slim format.
  • Open-top access for direct filling, checking and cleaning.
  • 1.9 mL nominal capacity in a 24 × 5.5 × 40 mm body-only format.
  • Molded 83 fabrication in JGS1 quartz for UV/Vis use.

Using this cell

Fill the cell from the open top and make sure the illuminated sample region is fully covered during measurement. Remove bubbles before reading, and keep the same orientation for blank and sample so the optical path stays consistent.

The stated 1.9 mL is a nominal capacity, not a minimum working volume. If your instrument uses a fixed beam height or your method works close to the lowest practical fill level, establish that fill condition in your own holder before routine use.

First-use check

  1. Inspect the optical faces and top opening for chips, residue or handling marks.
  2. Place the cell in the holder and confirm that it sits securely without twisting or side pressure.
  3. Run a blank at the intended fill level and check that the beam passes cleanly through the filled region.

Fit and optical alignment

This cuvette has a 24 × 5.5 × 40 mm body-only size, so holder clearance should be checked against that actual body geometry. The dimensions describe the bare optical body and do not establish compatibility with a particular clamp or instrument compartment.

Z Height is not stated for this SKU. If your instrument has a fixed beam center or tight holder clearance, check the beam position and support details before ordering.

English selection reference
Selection reference ↗

Solvents and cleaning

This cuvette uses Molded 83 fabrication in JGS1 quartz. This fabrication is commonly selected for methods involving organic solvents and applications where temperature can matter, but practical suitability still depends on the actual sample, concentration, temperature, exposure time and cleaning routine used with this open-top assembly.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with suitable non-abrasive materials. The listed wavelength range for this SKU is 200–2500 nm.

Included with this option

1 large-window cuvette. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We can review custom JGS1 quartz versions for changes to dimensions, optical path, capacity, optical windows, Z Height, opening style and fabrication requirements. Send a labelled drawing or holder details together with the required path, critical dimensions, sample conditions and target quantity. Contact us with SKU MQQLW004 if you need a modified version for a specific holder or optical layout.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQLW004) JGS1 Quartz Large-Window Cuvette, 3 mm Path, 1.9 mL”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare