(MQQMC058) Black-Wall Quartz Ultra-Micro Cuvette, 10 mm Path, 50 µL, Z Height 20 mm
$156.00
MQQMC058 is a JGS1 quartz ultra-micro cuvette for UV/Vis measurements, combining a 10 mm path with 50 µL nominal capacity in a black-wall, angled open-top format. Its 20 mm Z Height and 2 × 2.5 mm window are the key fit points for beam placement and filling technique. Sold as 1 piece.
Description
MQQMC058 combines a 10 mm optical path with a 50 µL nominal capacity in a black-wall JGS1 quartz ultra-micro cuvette for UV/Vis work. Its angled open top gives direct access from above, while the 20 mm Z Height and 2 × 2.5 mm window make beam placement and filling routine important parts of selection. This is a good fit when you need a small sample region but still want a full 10 mm path.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 50 µL
- Opening Configuration
- Angled Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Z Height | 20 mm |
| Optical Window Dimensions | 2 × 2.5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 50 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| MQ Grade | Standard 80 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Angled Open Top |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQMC058 when your method needs a 10 mm UV/Vis path in a very small-volume format and your holder aligns to a 20 mm beam centre height. The angled open top is useful for careful top filling and visual inspection, and the compact window size suits setups where the beam is well controlled at the sample region.
View the English selection reference. Also available in the product gallery.
What makes this option different
- 10 mm optical path with 50 µL nominal capacity for small-volume UV/Vis methods that still use a standard path length.
- Angled open top for direct filling and inspection from above, without a built-in closure.
- 20 mm Z Height from the base to the optical centre, which must match your holder geometry.
- 2 × 2.5 mm window that calls for a suitably placed beam and careful bubble control.
- Two-Way Light configuration for the defined transmission path used in UV/Vis measurement.
- Standard 80 adhesive-bonded construction for room-temperature water-based samples and buffers.
Using this cell
Fill from the open top so the liquid fully covers the illuminated region before measurement. With a small optical window and a 50 µL nominal capacity, filling technique matters: use a steady routine, inspect for trapped bubbles, and keep blank and sample orientation consistent.
This open-top format gives direct access for pipetting and checking the sample region. If your procedure depends on a cap, sealing or pressure handling, this listing does not establish those features for the supplied item.
First-use check
- Inspect the window area and top opening for residue, chips or visible damage.
- Seat the cell in the holder and confirm beam alignment at the 20 mm optical centre height.
- Run a blank with your intended filling routine and check for stable positioning and bubble-free coverage.
Fit and optical alignment
The body dimensions are 12.5 × 12.5 × 45 mm for the body only. That footprint may fit a holder, but correct use also depends on the beam meeting the 2 × 2.5 mm optical region at 20 mm above the base.
The angled top needs enough clearance for pipetting from above. The 50 µL value is the nominal capacity, not a minimum working volume, so confirm in your own setup that the fill level fully covers the beam path.

Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. It is generally used for room-temperature water-based samples and buffers. Avoid organic samples and organic cleaning solvents with this assembled cell.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces gently with suitable non-abrasive tissue.
Included with this option
1 ultra-micro cuvette. The listed price is for one cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different window size, Z Height, path length, body geometry or opening arrangement, send your holder or instrument details with a marked drawing or sketch. We can review custom JGS1 quartz options for dimensions, optical path, sample volume, windows, Z Height, closures, fabrication and tolerances.
Send a product-selection enquiry with SKU MQQMC058, your application details, sample conditions, required quantity and delivery destination.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.