(MQQMC059) Quartz Ultra-Micro Cuvette, 10 mm path, 100 µL nominal capacity, Black-Wall Cell, 20 mm Z Height
$156.00
MQQMC059 is a JGS1 quartz ultra-micro cuvette for UV/Vis measurements, combining a 10 mm path with 100 µL nominal capacity in a black-wall, angled open-top body. Its 20 mm Z Height and 2 × 5 mm window are the key fit points for beam placement and sample handling. Sold as 1 quartz ultra-micro cuvette.
Description
MQQMC059 combines a 10 mm optical path with a 100 µL nominal capacity in a black-wall JGS1 quartz ultra-micro cuvette for UV/Vis work. Its angled open top leaves direct access for filling from above, while the 2 × 5 mm window and 20 mm Z Height make the optical region more important than outside footprint alone when you check holder fit. This option suits methods that need a small-volume cell with a defined transmission path and direct top access.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 100 µL
- Opening Configuration
- Angled Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Z Height | 20 mm |
| Optical Window Dimensions | 2 × 5 mm |
| Sample Volume (Nominal) | 100 µL |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Angled Open Top |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Ultra-Micro Cuvette |
Choose this option
Choose MQQMC059 when you need a 10 mm path and 100 µL nominal capacity in a compact ultra-micro format, and your instrument aligns to a 20 mm beam centre height. The angled open top supports careful filling and inspection from above, and the 2 × 5 mm window is useful when your beam geometry suits a narrow but taller optical region.
What makes this option different
- 10 mm optical path with 100 µL nominal capacity for small-volume UV/Vis work without changing to a shorter path.
- 2 × 5 mm window for a narrow but taller optical region than smaller-window versions in the same family.
- 20 mm Z Height from the base to the optical centre for holder and beam-position matching.
- Angled open top for direct filling and visual inspection from above.
- Two-Way Light configuration for the defined transmission path used in routine UV/Vis measurement.
- Standard 80 adhesive-bonded construction for room-temperature water-based samples and buffers.
Structure and dimensions

Using this cell
Fill from the open top so the liquid fully covers the optical region, then inspect the sample area for bubbles before measurement. Use the same orientation and filling routine for blank and sample to keep the optical path and liquid coverage consistent.
The 100 µL value is the nominal capacity of the cell, not a minimum working volume. In practice, the fill you need depends on how your beam sits within the 2 × 5 mm window in your own instrument.
First-use check
- Inspect the window area and top opening for residue, chips or visible damage.
- Seat the cell in the holder and confirm beam alignment at the 20 mm optical centre height.
- Run a blank using your intended filling routine and check for stable positioning and bubble-free coverage.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The critical fit point here is the optical region at 20 mm above the base. A holder may accept the body shape, but the beam still needs to pass correctly through the 2 × 5 mm window, and you need enough clearance above the angled opening for pipetting.
This listing covers one open-top cell. It does not establish a supplied cap, a pressure rating or a general solvent list for all use conditions.

Solvents and cleaning
This cell uses adhesive-bonded quartz construction and Standard 80 fabrication. It is generally used for room-temperature water-based samples and buffers. Avoid organic samples and organic cleaning solvents with this assembled cell.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaners, and clean the optical faces gently with suitable non-abrasive optical tissue.
Included with this option
1 Quartz Ultra-Micro Cuvette. The listed price is for one cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, window size, Z Height, opening arrangement or body geometry, send your drawing or holder details for review. We can discuss custom JGS1 quartz versions for dimensions, optical path, sample volume, windows, Z Height, closures, fabrication and tolerance requirements.
Send a product-selection enquiry with SKU MQQMC059, your instrument or holder details, sample conditions, required quantity and delivery destination.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.







Reviews