(MQQMC026) Quartz Ultra-Micro Cuvette, 10 mm path, 20 µL nominal capacity, Black-Wall Small-Volume Cell

Weight50 g
SKU: MQQMC026

$168.00

In Stock

MQQMC026 is a JGS1 quartz ultra-micro cuvette with a 10 mm optical path, 20 µL nominal capacity and 10 mm Z Height for UV/Vis work. Its open-top Two-Way Light design supports direct filling in a compact body. The listed price is for 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQMC026 is a JGS1 quartz ultra-micro cuvette for UV/Vis spectroscopy with a standard 10 mm optical path in a small-volume format. It combines a 20 µL nominal capacity, 10 mm Z Height and Two-Way Light geometry in a compact open-top body, so you can match sample access, beam height and holder fit in one selection. The listed price is for 1 piece.

Path Length
10 mm
Sample Volume (Nominal)
20 µL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeUltra-Micro Cuvette
Measurement ModeUV/Vis Spectroscopy
Path Length10 mm
Light Transmission ConfigurationTwo-Way Light
Z Height10 mm
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)20 µL
External Dimensions12.5 × 12.5 × 45 mm
Cell Body Dimensions12.5 × 12.5 × 45 mm
External Dimensions ScopeBody Only
Body Height45 mm
Base Dimensions12.5 × 12.5 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodStandard 80
Opening ConfigurationOpen Top
Pack Quantity1 Piece
Package Contents1 × Quartz Ultra-Micro Cuvette

Choose this option

Choose MQQMC026 when you need a 10 mm path in an ultra-micro quartz cell and your holder aligns to a 10 mm beam centre from the base. The open top suits direct pipetting, and the 20 µL nominal capacity helps plan small-volume sample preparation without moving to a larger body format.

What makes this option different

  • 10 mm optical path for methods that require this path length.
  • 20 µL nominal capacity for small-volume sample planning.
  • 10 mm Z Height from the cell bottom to the optical centre.
  • Two-Way Light geometry for measurement across one defined optical axis.
  • Open-top body for direct loading.
  • Standard 80 adhesive-bonded quartz construction.

Structure and dimensions

Product structure and the listed configuration.
Product structure and the listed configuration.Open image ↗

Using this cell

Fill from the open top and make sure the illuminated sample region is fully covered in the measurement position. Because 20 µL is the nominal capacity, not a minimum working volume, your actual fill should be set by beam coverage and liquid level in your method.

Keep the same orientation for blank and sample runs, and check that no droplets or residue remain on the outside optical faces before reading.

First-use check

  1. Inspect the optical faces and sample region for chips, residue or handling marks.
  2. Place the cell in the holder and verify that the beam aligns with the 10 mm optical centre.
  3. Run a blank in the same orientation you will use for the sample, then recheck for bubbles or exterior droplets.

Fit and optical alignment

View the English selection reference.

The stated 12.5 × 12.5 × 45 mm dimensions apply to the body only. Check holder seating and top access against the bare cell body, and confirm that your instrument beam meets the 10 mm optical centre from the base.

If your method depends on a particular beam footprint or aperture, review that fit before ordering. Body height, nominal capacity and Z Height describe different parts of the cell geometry and should be matched separately to your setup.

English selection reference
Selection reference ↗

Solvents and cleaning

Standard 80 is an adhesive-bonded quartz construction generally chosen for room-temperature water-based samples and buffer solutions. Avoid organic samples and organic cleaning solvents with this construction.

If your method involves organic solvents, aggressive liquids, heat or long soaking periods, check the exact sample and cleaning conditions before use. Do not use hydrofluoric acid on quartz, and avoid hot strong alkalis and abrasive cleaning materials. Wipe the optical faces gently with non-abrasive optical tissue.

Included with this option

1 Quartz Ultra-Micro Cuvette.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for changes involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication requirements. Send your drawing or holder details, critical dimensions, sample conditions and quantity for review.

Send a product-selection enquiry with SKU MQQMC026 and your application details.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQMC026) Quartz Ultra-Micro Cuvette, 10 mm path, 20 µL nominal capacity, Black-Wall Small-Volume Cell”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare