(MQQMC014) Quartz Ultra-Micro Cuvette, 3 mm path, 45 µL nominal capacity, Black Walls, 8.5 mm Z Height
$533.00
MQQMC014 is a JGS1 quartz Ultra-Micro Cuvette for fluorescence spectroscopy with a 3 mm path, 45 µL nominal capacity and Three-Way Light access. Its stopper-style opening, 3 × 5 mm window area and 8.5 mm Z Height suit small-sample fluorescence setups that need side optical access. Sold as 1 piece with accompanying closure.
Description
MQQMC014 is a JGS1 quartz Ultra-Micro Cuvette for fluorescence spectroscopy with a 3 mm optical path and 45 µL nominal capacity. This option combines Three-Way Light access, an 8.5 mm Z Height and a stopper-style opening in a compact body, making it useful when your setup needs side optical access and a small sample region rather than a full-size cuvette chamber.
- Path Length
- 3 mm
- Sample Volume (Nominal)
- 45 µL
- Opening Configuration
- Stoppered Opening
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 3 mm |
| Light Transmission Configuration | Three-Way Light |
| Z Height | 8.5 mm |
| Optical Window Dimensions | 3 × 5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 45 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Fabrication Method | Standard 80 |
| Opening Configuration | Stoppered Opening |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Ultra-Micro Cuvette; Accompanying closure |
Choose this option
Choose MQQMC014 when your method uses fluorescence geometry with optical access from more than one side and a short 3 mm path. The stopper-style opening suits loading and covering a small chamber, while the 45 µL nominal capacity and 3 × 5 mm window area help you plan sample scale and beam placement in a compact format.
What makes this option different
- Three-Way Light configuration provides optical access from three sides for suitable fluorescence arrangements.
- 3 mm path with 45 µL nominal capacity suits short-path measurements in a very small chamber.
- Stopper-style opening gives a covered opening rather than a fully open rim during routine handling.
- 3 × 5 mm window area should be matched to your beam geometry and viewing arrangement.
- 8.5 mm Z Height matters when your holder has a defined beam-center position from the cell base.
- Standard 80 adhesive-bonded construction is commonly chosen for routine aqueous samples and buffer solutions.
Using this cell
Fill the cuvette so the illuminated sample region is fully covered in your actual measurement position. Because this is a very small chamber, load the blank and the sample in the same orientation and check carefully for bubbles before placing the cell in the instrument.
The opening is designed for a stopper-style closure. The accompanying closure is included with this option, but closure material and sealing or pressure capability are not specified here.
First-use check
- Inspect the optical faces and the sample chamber for chips, residue or handling marks before use.
- Place the cell in the holder with a suitable blank and confirm that the beam passes through the intended window area.
- After filling, remove bubbles and exterior droplets, then repeat the blank in the same orientation.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
Check the uncapped body size of 12.5 × 12.5 × 45 mm against your holder clearance, and match the 8.5 mm Z Height to the beam position of your instrument. The stated dimensions apply to the uncapped cell body rather than the overall height with the closure in place.
The nominal capacity is not a minimum working volume. If your fluorescence setup is sensitive to fill height or beam coverage, verify those points with your own holder and optical geometry before routine use.

Solvents and cleaning
Standard 80 is an adhesive-bonded quartz construction. MQ recommends routine aqueous samples and buffers at room temperature for this construction. Avoid organic samples and organic cleaning solvents; if your method needs them or involves heated treatment, ask about a suitable Sintered or Molded alternative before ordering.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive optical tissue and a liquid appropriate for the complete assembly.
Included with this option
1 MQQMC014 cuvette with its accompanying closure. The listed price is for one cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving path length, sample volume, external size, optical windows, Z Height, closure details and tolerances. If your holder or fluorescence geometry is specific, send a drawing or labelled sketch with the critical dimensions and beam position.
Send a product-selection enquiry with SKU MQQMC014, your holder details, sample conditions, quantity and delivery destination.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.










Reviews