Site Navigation

(MQQFL077) Quartz Screw-Top Cuvette, 8 mm path, 500 µL nominal capacity, Raised-Base Sample Chamber

Weight150 g
SKU: MQQFL077

$419.00

In Stock

MQQFL077 is a JGS1 quartz screw-top cuvette for fluorescence work with an 8 mm optical path, Four-Way Light layout and 500 µL nominal capacity. Its compact 10 × 10 mm body section, 8 × 8 × 8 mm internal chamber and M6 threaded top suit closed-top sample handling with side optical access. Sold as 1 piece with the accompanying closure.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFL077 is a JGS1 quartz screw-top cuvette for fluorescence spectroscopy with an 8 mm optical path, Four-Way Light geometry and 500 µL nominal capacity. It combines a compact 10 × 10 mm optical body with an 8 × 8 × 8 mm internal chamber and a threaded top, so you can work in a closed-top format without giving up side optical access around the sample region. Sold as one piece with the accompanying closure.

Path Length
8 mm
Sample Volume (Nominal)
500 µL
Opening Configuration
Single Threaded Neck

Selection Specifications

Product KindCuvette
Cell TypeScrew-Top Cuvette
Measurement ModeFluorescence Spectroscopy
Path Length8 mm
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)500 µL
External Dimensions10 × 10 × 20 mm
Body Height20 mm
Overall Height with Closure49 mm
Base Dimensions10 × 10 mm
Internal Dimensions8 × 8 × 8 mm
MaterialQuartz
Material GradeJGS1
Closure TypeScrew Cap
Port ThreadM6
Fabrication MethodMolded 83
Opening ConfigurationSingle Threaded Neck
Closure ThreadM6
Pack Quantity1 Piece
Package Contents1 × Quartz Screw-Top Cuvette; Accompanying closure

Choose this option

Choose MQQFL077 when you need a compact fluorescence cuvette with a defined 8 mm path and a screw-cap opening rather than an open chamber. The small chamber size helps when your method is built around sub-millilitre filling, and the Four-Way Light layout supports fluorescence arrangements that use side illumination or side collection with access around the sample region.

What makes this option different

  • 8 mm optical path for methods designed around that transmission length.
  • Four-Way Light layout with side optical access suited to fluorescence geometry.
  • 500 µL nominal capacity with an 8 × 8 × 8 mm internal chamber.
  • M6 single threaded neck in a compact screw-top format.
  • 10 × 10 × 20 mm bare optical body with 49 mm overall height when capped.

Using this cell

Fill through the threaded top opening, then seat the closure before measurement. Keep the cell orientation consistent between blank and sample, especially if your optical arrangement uses specific side faces for excitation or collection.

The stated 500 µL is the nominal chamber capacity, not a minimum working volume. Fill high enough to cover the illuminated region in your setup, and remove bubbles before taking readings.

First-use check

  1. Inspect the optical faces and threaded opening for chips, dust or handling marks.
  2. Test the cuvette in the intended holder with a blank to confirm seating and cap clearance.
  3. After filling, remove bubbles and wipe the outside faces before the first reading.

Fit and optical alignment

View the English selection reference. Also available in the product gallery.

The 10 × 10 × 20 mm dimensions describe the bare optical body only. For installation, also allow for the threaded neck and the full capped height of 49 mm, and make sure your holder leaves enough room to fit and remove the cap comfortably.

Z Height is not stated for this SKU. If your instrument depends on a defined beam-center height, check that requirement against your holder or optical bench before ordering.

English selection reference
Selection reference ↗

Solvents and cleaning

Molded 83 is used on MQ for quartz cuvettes commonly selected for organic-solvent methods and applications that may involve elevated temperature. Suitability still depends on the complete assembled cell, including the closure and your actual sample and cleaning conditions.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive optical tissue and use a cleaning routine that is suitable for the full assembly.

Included with this option

1 Quartz Screw-Top Cuvette and the accompanying closure. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for changes to path length, chamber size, body envelope, optical access, closure details and tolerance requirements. If holder fit or beam position is important, send a drawing or labelled sketch with the dimensions that matter for your setup.

Send a product-selection enquiry with SKU MQQFL077, your holder details, sample conditions and quantity.

Additional information

Weight150 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFL077) Quartz Screw-Top Cuvette, 8 mm path, 500 µL nominal capacity, Raised-Base Sample Chamber”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare