Site Navigation

(MQQPA020) Quartz Particle Analysis Cell, 44/4 mm paths, Sloping-Side Particle Cell

Weight50 g
SKU: MQQPA020

$1,428.00

In Stock

JGS1 quartz particle analysis cell with a 44 mm primary path, a 4 mm secondary path and Four-Way Light access in one body. Its open sample chamber and sloping-side form suit particle-analysis setups built around this specific cell geometry. The listed price is for 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQPA020 is a JGS1 quartz particle analysis cell with a 44 mm primary path, a 4 mm secondary path and Four-Way Light geometry. Its open-top format gives direct access to the sample chamber, while the sloping-side body helps identify it as a specific particle-analysis cell rather than a general rectangular cuvette. This sale is for 1 quartz cell.

Path Length
44 mm / 4 mm (dual path)
Cell Type
Particle Analysis Cell
Opening Configuration
Open Sample Cell

Selection Specifications

Product KindSpecialized Cell
Cell TypeParticle Analysis Cell
Measurement ModeParticle Analysis
Path Length44 mm / 4 mm (dual path)
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
External Dimensions56 × 11 × 75 mm
Body Height75 mm
Base Dimensions56 × 11 mm
Internal Dimensions44 × 4 × 75 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodMolded 83
Opening ConfigurationOpen Sample Cell
Pack Quantity1 Piece
Package Contents1 × Quartz Particle Analysis Cell

Choose this option

Choose MQQPA020 when your method uses this 44/4 mm dual-path arrangement and a four-side optical layout in a particle-analysis setup. The open chamber is useful when you need straightforward filling and rinsing, and the sloping-side body should be matched to the holder shape used by your instrument or fixture.

What makes this option different

  • 44 mm and 4 mm optical paths in one cell body for methods built around two defined light directions.
  • Four-Way Light configuration for optical access on four sides in compatible particle-analysis layouts.
  • Open Sample Cell format for direct sample loading and cleaning without a built-in closure.
  • Sloping-side body geometry that should be checked against the holder instead of being treated as a standard square cuvette profile.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Fill the sample chamber from the open top and place the cell in the same orientation for blanks, backgrounds and sample runs. In particle-analysis work, keep the optical faces and sample region free from dust, residue and visible bubbles before measurement.

If you are replacing another cell style, rerun your blank or background with this exact geometry in place. Consistent orientation matters because the cell provides more than one defined optical direction.

First-use check

  1. Inspect the optical faces and open sample chamber for chips, dust or handling residue.
  2. Place the cell in the holder and verify seating and alignment with a suitable blank or background.
  3. After filling, remove exterior droplets and visible bubbles before measurement.

Fit and optical alignment

View the English selection reference.

The body dimensions are 56 × 11 × 75 mm, and the stated internal dimensions are 44 × 4 × 75 mm. Check holder clearance, support surfaces and beam position against this body shape before ordering, especially if your current fixture was designed around another particle cell profile.

Z Height is not stated for this option. Where beam-center height is critical, match the cell against your holder drawing or existing cell reference before purchase.

English selection reference
Selection reference ↗

Solvents and cleaning

Molded 83 quartz is commonly selected for methods involving organic solvents or heated measurement conditions. For this open quartz cell, choose your sample and cleaning routine around the actual liquids and contact conditions used in the method.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning materials. Clean the optical faces gently with non-abrasive laboratory tissue and a suitable cleaning liquid for quartz.

Included with this option

1 Quartz Particle Analysis Cell. The listed price is for 1 piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz projects for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a drawing or labelled sketch together with your holder details, sample conditions and target quantity.

Send a product-selection enquiry with SKU MQQPA020 if you need a different geometry or want us to review fit before ordering.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQPA020) Quartz Particle Analysis Cell, 44/4 mm paths, Sloping-Side Particle Cell”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare