(MQQFC138) Quartz Micro Flow Cell, 0.5 mm Path, 136 µL, Bulged Tube Ends

Weight50 g
SKU: MQQFC138

$708.00

In Stock

JGS1 quartz micro flow cell with a 0.5 mm optical path and 136 µL nominal capacity. Two tubes project from the same broad face; each is 3 mm OD / 2 mm ID with a local 3.5 mm OD bulge. The low-profile body measures 40 × 14.5 × 3 mm, excluding the tubes. Molded 83 construction; one cell supplied.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC138 is a low-profile quartz micro flow cell with a 0.5 mm optical path and two projecting connections on the same broad face. The small nominal sample capacity and locally bulged tube ends distinguish it from a plain plate cell or a cell with straight opposite-end connections.

Path Length
0.5 mm
Sample Volume (Nominal)
136 µL
Opening Configuration
Two Tubes on One Face

Selection Specifications

Product KindFlow Cell
Cell TypeFlow Cell
Measurement ModeUV/Vis Spectroscopy
Path Length0.5 mm
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)136 µL
External Dimensions40 × 14.5 × 3 mm
Cell Body Dimensions40 × 14.5 × 3 mm
External Dimensions ScopeBody Only
Internal Dimensions34 × 10 × 0.5 mm
MaterialQuartz
Material GradeJGS1
Port Count2
Tube Outer Diameter (OD)3 mm
Tube Inner Diameter (ID)2 mm
Fabrication MethodMolded 83
Opening ConfigurationTwo Tubes on One Face
Port LayoutOne broad face near end A, shown on the left; Same broad face near end B, shown on the right
Pack Quantity1 Piece
Package Contents1 × Quartz Flow Cell

Choose this option

Choose this option when your method calls for a 0.5 mm measurement path and the stated 136 µL nominal sample capacity. Check the flat body support and space above both projecting tube ends as separate installation requirements.

What makes this option different

  • 0.5 mm optical path: this identifies the short measurement distance, rather than the 3 mm overall body thickness.
  • 136 µL nominal capacity: use the stated capacity for selection, and establish the actual priming volume of your complete liquid circuit. It is not a minimum working-fill specification.
  • Two connections on one broad face: both tubes need clearance on the same side of the plate-like body, with external tubing supported independently.
  • 3 mm OD / 2 mm ID tubes: the local bulged region is 3.5 mm OD. That bulge is a profile dimension rather than an M3.5 thread designation.
  • 40 × 14.5 × 3 mm body: the drawing separately marks an 11 mm upright tube leg. The 11 mm annotation is not a complete installed height or a Z Height.

Using this cell

Keep handling and connection loads off the projecting tubes. Flush with a suitable blank, inspect the narrow sample region for bubbles and use a consistent orientation for reference and sample measurements. External tubing adds volume and must be considered when priming or changing samples.

First-use check

  1. Inspect the optical faces, body and connection edges for damage or residue.
  2. Check holder support, beam direction and connection clearance before completing the liquid circuit.
  3. Flush with a suitable blank, remove bubbles and establish a stable reference before measuring the sample.

Fit and optical alignment

Support the 40 × 14.5 × 3 mm body without twisting it and leave clearance for both projecting tubes, their local 3.5 mm bulges and your tubing bends. Use the stated 0.5 mm optical path for alignment. Do not substitute the marked 11 mm tube leg for a base-to-beam-centre height.

View the English selection reference.

English selection reference
Selection reference ↗

Solvents and cleaning

Molded 83: Molded 83 identifies the integrated-forming construction mapped for this option. Select sample and cleaning conditions for the complete wetted assembly, including connections and any tubing you add. Construction alone does not establish a pressure rating or compatibility with every solvent.

Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Wipe exterior optical faces gently with non-abrasive optical tissue, and keep handling loads off projecting connections.

Included with this option

One quartz micro flow cell with the two fixed projecting tubes shown. The listed price is per cell; external tubing and a holder are not stated as included.

Availability and ordering

Contact us to confirm current availability and dispatch timing for your quantity. For a required delivery date, check timing before checkout; preparation and production are separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz projects involving optical paths, sample regions, optical access, connection geometry and mounting dimensions. Modified designs and prototype batches are quoted separately. Send your drawing, holder details, sample conditions and quantity through the contact page, and include MQQFC138.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC138) Quartz Micro Flow Cell, 0.5 mm Path, 136 µL, Bulged Tube Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare