(MQQFC139) Quartz Flow Cell, 10 mm Path, 200 µL, Straight and Bent Tubes
$275.00
JGS1 quartz flow cell with a 10 mm optical path and 200 µL nominal capacity. One straight tube and one bent tube provide different exit directions around the compact sample region; both tubes are 3 mm OD / 1 mm ID. Two opposing optical faces support transmission measurement. Molded 83 fabrication; one cell supplied.
Description
MQQFC139 combines a 10 mm optical path with a 200 µL nominal sample region and a mixed straight-and-bent connection layout. The two quartz tubes leave the body in different directions, making tube routing a key part of selecting this compact flow-cell format.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 200 µL
- Opening Configuration
- One Straight and One Bent Tube
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 200 µL |
| Body Height | 12.5 mm |
| Internal Dimensions | 9 × 2.5 × 10 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 3 mm |
| Tube Inner Diameter (ID) | 1 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | One Straight and One Bent Tube |
| Port Layout | Straight horizontal tube at the left of the body as drawn; Bent tube rising at the right of the body as drawn |
| Wall Thickness | 1.25 mm |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose this cell when a straight connection on one side and a bent connection on the other fit your holder or nearby hardware better than two opposed straight tubes. Check the bend and the clearance for connected tubing as carefully as the optical path.
What makes this option different
- One straight and one bent quartz tube: the asymmetric routing provides two different exit directions. Tube shape does not assign inlet and outlet roles.
- 3 mm OD / 1 mm ID connections: these are dimensions of the cell’s glass tubes. Select tubing or adapters for the appropriate connection method and support them without loading the glass bend.
- Two opposing optical faces: the 10 mm measurement path passes through the sample region. The pale non-measurement surfaces shown in the photographs are retained as supplied, rather than presented as extra optical windows.
- 200 µL nominal capacity: this describes the cell’s stated sample capacity. Connecting lines add their own volume, and nominal capacity is not a minimum working-fill specification.
Using this cell
Support the body while attaching or removing tubing. Avoid twisting or bending the projecting tubes, especially at the curved section. Fill and flush so that the measurement region is covered without bubbles, then establish a stable blank in the same seating and orientation used for samples.
First-use check
- Inspect the optical faces, straight tube, bent section and tube ends for damage or residue.
- Check holder support and clearance with the planned tubing arrangement before filling.
- Flush with a suitable blank, remove bubbles and verify stable transmission before measuring the sample.
Fit and optical alignment
The dimensioned view marks a 12.5 mm body height, a 31 mm span and a 9 × 2.5 × 10 mm internal region. The marked span does not define the complete installed envelope or the height of the bent tube. Leave additional clearance for both connections, adapters and tubing bends; check beam-centre alignment in your own holder.
View the English selection reference.

Solvents and cleaning
This JGS1 cell uses Molded 83 fabrication. Check sample and cleaning conditions for the complete cell and every wetted tubing or adapter material. For organic solvents or heated cleaning, confirm suitability for the chemical, concentration, temperature and contact time rather than treating the fabrication designation as a complete-assembly limit.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaners. Clean exterior optical faces gently with non-abrasive optical tissue and avoid mechanical force on the projecting glass tubes.
Included with this option
One quartz flow cell with the straight and bent connections shown. The listed price is per cell; mating tubing, adapters and supports are not stated as included.
Availability and ordering
Contact us to confirm current availability and dispatch timing for your quantity. For a required delivery date, check timing before checkout; preparation and production are separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects involving tube direction, connection size, optical path or cell geometry. Modified designs and prototype batches are quoted separately from this SKU. Send a labelled sketch, available installation space, sample conditions and quantity through the contact page, and include MQQFC139.
Design notes for this configuration: 10 mm Quartz Flow Cell: Why One Straight and One Bent Tube?
Additional information
| Weight | 150 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.