(MQQMC018) Quartz Fluorescence Cuvette, 6/36 mm paths, Locating-Rail Geometry

Weight120 g
SKU: MQQMC018

$480.00

In Stock

JGS1 quartz fluorescence cuvette with dual 6 mm and 36 mm optical paths, Four-Way Light access and an open-top body with locating-rail geometry. This Standard 80 adhesive-bonded format suits fluorescence work that needs repeatable orientation in a compatible holder. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQMC018 is a JGS1 quartz fluorescence cuvette with dual 6 mm and 36 mm optical paths in one open-top body. Its Four-Way Light layout and locating-rail geometry make it useful for fluorescence setups where optical direction and repeatable seating both matter during routine use.

Path Length
6 mm / 36 mm (dual path)
Cell Type
Fluorescence Cuvette
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeFluorescence Cuvette
Measurement ModeFluorescence Spectroscopy
Path Length6 mm / 36 mm (dual path)
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
External Dimensions40 × 10 × 90 mm
External Dimensions ScopeBody Only
Body Height90 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodStandard 80
Opening ConfigurationOpen Top
Wall Thickness2 mm
Pack Quantity1 Piece
Package Contents1 × Quartz Fluorescence Cuvette

Choose this option

Choose MQQMC018 when your method uses two defined optical directions in the same cell and your holder can make use of the locating-rail geometry. The open top keeps filling and rinsing direct, while the longer 90 mm body and shaped exterior are selected for fit and orientation rather than as a general-purpose square cuvette.

What makes this option different

  • Dual 6 mm and 36 mm paths provide two defined optical directions in one cuvette body.
  • Four-Way Light configuration allows optical access from four sides around the sample region.
  • Locating-rail geometry helps position the cell in a compatible holder with repeatable orientation.
  • Open-top JGS1 quartz body allows direct filling from above.
  • Standard 80 adhesive-bonded construction is typically chosen for room-temperature water-based samples and buffer solutions.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Fill the cuvette from the open top and keep the same orientation for blank and sample measurements. With dual optical directions in the same body, consistent seating matters because changing orientation changes the path used by the instrument.

Before measurement, make sure the illuminated region is fully covered by sample and remove bubbles from the optical area. Wipe the outside faces dry before placing the cell in the holder.

First-use check

  1. Inspect the optical faces and top opening for chips, residue or handling marks.
  2. Test the fit in your holder and confirm the beam passes through the intended optical direction.
  3. Run a blank in the same orientation you will use for the sample.

Fit and optical alignment

View the English selection reference. Also available in the product gallery.

The body dimensions are 40 × 10 × 90 mm, stated for the body only, and the wall thickness is 2 mm. Check holder clearance, seating geometry and side access carefully. The locating rail is part of the body shape, but it does not by itself establish compatibility with a particular instrument holder.

Z Height is not established for this option. If your instrument has a fixed beam position, compare the holder opening and beam height before ordering rather than relying on the exterior outline alone.

English selection reference
Selection reference ↗

Solvents and cleaning

This cuvette uses Standard 80 adhesive-bonded construction. It is generally selected for room-temperature water-based samples and buffer solutions. Avoid organic samples and organic cleaning solvents with this construction.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning materials. If your method involves aggressive chemicals, elevated temperature or long contact time, check the exact sample and cleaning conditions before ordering.

Included with this option

1 Quartz Fluorescence Cuvette.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for changes to path length, body dimensions, optical windows, Z Height, opening style and other geometry details. Send a drawing or sketch with the dimensions that matter to your holder and optical setup, together with sample conditions and quantity, and we can review a suitable custom option.

Send a product-selection enquiry with SKU MQQMC018 and your holder or application details.

Additional information

Weight120 g

Reviews

There are no reviews yet.

Be the first to review “(MQQMC018) Quartz Fluorescence Cuvette, 6/36 mm paths, Locating-Rail Geometry”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare