(MQQFL042) Quartz Fluorescence Cuvette, 5 mm path, Short-Path Fluorescence Cell
Description
MQQFL042 is a quartz fluorescence cuvette for UV/Vis and fluorescence measurements that use a 5 mm optical path and four-way optical access around the sample region. The open-top chamber gives direct access for filling, rinsing and sample changes, and the 1750 µL nominal capacity provides a practical working size for routine handling. This option is supplied as one cell with an accompanying closure.
- Path Length
- 5 mm
- Sample Volume (Nominal)
- 1.75 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy; UV/Vis Spectroscopy |
| Path Length | 5 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 1.75 mL |
| Material | Quartz |
| Closure Included | Yes |
| Opening Configuration | Open Top |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Fluorescence Cuvette; Accompanying closure |
Choose this option
Choose MQQFL042 when your setup needs a 5 mm path and optical access from more than one pair of faces. It suits methods where cell orientation matters and where top access helps with pipetting, blank preparation and cleaning between runs.
What makes this option different
- 5 mm optical path for methods built around this short-path quartz cell format.
- Four-Way Light configuration supports optical access on four sides of the sample region.
- 1750 µL nominal capacity gives a practical chamber size for routine filling and handling.
- Open-top body with accompanying closure keeps loading and rinsing straightforward.
Structure and dimensions

Using this cell
Fill the cell from the top and keep the same orientation in the holder for blank and sample measurements. In fluorescence work, stable positioning matters because rotating the cell can change the optical geometry used by the instrument.
Use enough sample to cover the illuminated region and remove bubbles before measurement. The 1750 µL figure is a nominal cell capacity, not a minimum working volume.
First-use check
- Inspect the optical faces and sample chamber before first use.
- Place the cell in the holder with a blank and confirm stable seating and repeatable positioning.
- After filling, remove bubbles and exterior droplets before collecting data.
Fit and optical alignment
View the English selection reference.
Check the holder clearance and beam position before ordering if your instrument has a fixed holder or beam-height requirement. A Four-Way Light cell gives multi-side optical access, but Z Height is not established for this SKU, so a specific instrument match should not be assumed from path length alone.

Solvents and cleaning
Choose the sample and cleaning routine for the complete cell assembly. If your method uses organic solvents, aggressive chemicals, elevated temperature or long contact time, review suitability for the full assembly before use.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaners, and clean the optical faces gently with non-abrasive optical tissue.
Included with this option
1 quartz fluorescence cuvette and 1 accompanying closure. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, external size, optical layout, holder fit or opening style, please send your existing cell reference or holder drawing through the contact page. Custom projects are reviewed separately from this listed SKU.