(MQQFL039) Quartz Fluorescence Cuvette, 2 mm Path, 700 µL, Neutral Solutions Only

Weight50 g
SKU: MQQFL039

$51.00

In Stock

Quartz fluorescence cuvette with a 2 mm optical path, 700 µL nominal capacity and optical access through four side faces. This open-top version is for neutral solutions only; it is supplied as one cuvette with a cover. Match the beam position and holder geometry to the cell before use.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFL039 is a quartz fluorescence cuvette with a 2 mm optical path, Four-Way Light access and a 700 µL nominal capacity. It suits UV/Vis and fluorescence methods that need a short-path open-top cell while keeping optical access on four sides around the sample region. This version is restricted to neutral solutions and is supplied as one cuvette with a cover and storage box.

Path Length
2 mm
Sample Volume (Nominal)
700 µL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeFluorescence Cuvette
Measurement ModeFluorescence Spectroscopy; UV/Vis Spectroscopy
Path Length2 mm
Light Transmission ConfigurationFour-Way Light
Sample Volume (Nominal)700 µL
MaterialQuartz
Closure TypeFlat Lid
Closure IncludedYes
Opening ConfigurationOpen Top
Pack Quantity1 Piece
Package Contents1 × Quartz Fluorescence Cuvette; Accompanying closure

Choose this option

Choose this cell when your method is built around a 2 mm path and four-sided optical access, and when your sample conditions stay within neutral-solution use. The open-top format supports direct filling and rinsing, and the accompanying closure lets you handle the cell in the supplied configuration for routine bench work.

What makes this option different

  • 2 mm optical path for methods set up around this short transmission distance.
  • Four-Way Light configuration for optical access on four sides around the sample chamber.
  • 700 µL nominal capacity for a compact chamber without implying a verified minimum working fill.
  • Restricted to neutral solutions for chemistry-specific use rather than general solvent use.

Structure and dimensions

2 mm quartz fluorescence cuvette with an open-top sample chamber.
2 mm quartz fluorescence cuvette with an open-top sample chamber.Open image ↗
Quartz fluorescence cell comparison showing 1, 2, 3 and 5 mm optical paths with their nominal capacities.
Quartz fluorescence cell comparison showing 1, 2, 3 and 5 mm optical paths with their nominal capacities.Open image ↗

Using this cell

Fill from the open top and use the accompanying closure as supplied. Keep the orientation the same between blank and sample measurements so the same optical faces and optical directions are used each time.

Make sure the sample level covers the active beam region, then remove bubbles and wipe away exterior droplets before measurement. The 700 µL figure is the nominal cell capacity, not a stated minimum working volume.

First-use check

  1. Inspect the quartz faces, top opening and closure-contact area before first use.
  2. Rinse with a suitable neutral blank and confirm stable seating in the holder.
  3. Run a blank in the same orientation you will use for the sample.

Fit and optical alignment

View the English selection reference.

Check the holder opening, seating depth and instrument beam position before ordering, especially if you are replacing a cell in a fixed mount. Z Height is not established for this SKU, so fit should be checked against your current cell or holder drawing rather than assumed from the 2 mm path alone.

Where the holder has limited clearance or a fixed beam center, reviewing the existing cell reference or holder dimensions is the safest approach.

English selection reference
Selection reference ↗

Solvents and cleaning

Use this version with neutral solutions, in line with the supplier restriction for this SKU. If your method involves organic solvents, aggressive reagents, heated samples or extended soaking, choose a different cell selected for those conditions rather than this listed option.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive optical tissue and a suitable mild cleaner for the permitted sample conditions.

Included with this option

1 quartz fluorescence cuvette with a cover and storage box. Gallery comparisons show other path lengths for reference; the listed sale unit is one 2 mm cell, not a multi-cell set.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

If you need a different path length, body format or chemistry suitability, please send your application details, current cell reference or holder drawing through our contact page. Custom JGS1 quartz projects are reviewed separately from this listed SKU.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFL039) Quartz Fluorescence Cuvette, 2 mm Path, 700 µL, Neutral Solutions Only”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare