Site Navigation

(MQQFL041) Quartz Fluorescence Cuvette, 5 mm Path, 1750 µL, Neutral Solutions Only

Weight50 g
SKU: MQQFL041

$39.00

In Stock

Quartz fluorescence cuvette with a 5 mm optical path, 1750 µL nominal capacity and optical access through four side faces. This open-top version is for neutral solutions only; it is supplied as one cuvette with a cover. Match the beam position and holder geometry to the cell before use.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFL041 is a quartz fluorescence cuvette for UV/Vis and fluorescence measurements that use a 5 mm optical path and optical access on four sides of the sample region. The open-top body makes filling and rinsing straightforward, and the 1750 µL nominal capacity gives a practical chamber size for routine handling. This version is restricted to neutral solutions and is supplied as one cell with a cover and storage box.

Path Length
5 mm
Sample Volume (Nominal)
1.75 mL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeFluorescence Cuvette
Measurement ModeFluorescence Spectroscopy; UV/Vis Spectroscopy
Path Length5 mm
Light Transmission ConfigurationFour-Way Light
Sample Volume (Nominal)1.75 mL
MaterialQuartz
Closure IncludedYes
Opening ConfigurationOpen Top
Pack Quantity1 Piece
Package Contents1 × Quartz Fluorescence Cuvette; Accompanying closure

Choose this option

Choose MQQFL041 when your method needs a 5 mm path in a four-way optical layout and you want direct top access for filling, blank preparation and cleaning. It suits workflows where the cell stays in a defined orientation while illumination or signal collection is arranged around the sample chamber.

What makes this option different

  • 5 mm optical path for methods set up around this short transmission distance.
  • Four-Way Light configuration supports optical access from four sides of the sample region.
  • 1750 µL nominal capacity provides a larger chamber than very small short-path cells.
  • Open-top body with accompanying closure allows direct filling and routine handling.

Structure and dimensions

5 mm quartz fluorescence cuvette with an open-top sample chamber.
5 mm quartz fluorescence cuvette with an open-top sample chamber.Open image ↗
Quartz fluorescence cell comparison showing 1, 2, 3 and 5 mm optical paths with their nominal capacities.
Quartz fluorescence cell comparison showing 1, 2, 3 and 5 mm optical paths with their nominal capacities.Open image ↗

Using this cell

Fill from the top and use enough sample to cover the illuminated region used by your setup. For fluorescence work, keep the cell orientation the same for blank, standard and sample so the optical geometry does not shift between runs.

Remove bubbles from the optical region before measurement, and wipe exterior faces carefully so droplets do not affect the reading. The 1750 µL figure is a nominal cell capacity, not a minimum working volume.

First-use check

  1. Inspect the optical faces and sample chamber for chips, residue or handling marks.
  2. Seat the cell in the holder and run a blank to confirm stable positioning.
  3. Check that the fill level covers the illuminated region without bubbles in the optical path.

Fit and optical alignment

View the English selection reference.

Check the holder clearance and beam position against your instrument before ordering. A Four-Way Light cell supports multi-side optical access, but Z Height is not established for this SKU, so beam-height-critical instruments should be checked against your current cell or holder drawing.

English selection reference
Selection reference ↗

Solvents and cleaning

This version is restricted to neutral solutions. Use it for neutral samples and matching cleaning routines only.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning materials, and clean the optical faces gently with non-abrasive optical tissue.

Included with this option

1 quartz fluorescence cuvette with a cover and storage box. Gallery comparisons show other path lengths for reference; the listed sale unit is one 5 mm cell, not a multi-cell set.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

For a different path length, optical layout, holder fit or opening style, please send your holder details or a dimensioned sketch through the contact page. Custom projects are reviewed separately from this listed SKU.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFL041) Quartz Fluorescence Cuvette, 5 mm Path, 1750 µL, Neutral Solutions Only”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare