(MQQMC015) Quartz Demountable Cuvette, 0.4 mm path, 11 µL nominal capacity, 6 mm Diameter Recess, 15 mm Center
$239.00
MQQMC015 is a JGS1 quartz demountable cuvette with a 0.4 mm optical path, 11 µL nominal capacity and a 6 mm diameter circular sample recess. The removable cover plate and 15 mm center height suit setups that need direct sample placement and a defined beam position. The listed price is for one cell set.
Description
MQQMC015 is a JGS1 quartz demountable cuvette with a removable cover plate, a 0.4 mm optical path and an 11 µL nominal capacity. The 6 mm diameter circular recess gives direct access to the sample area before the cover is seated, which is useful for fluorescence work and solid or powder sample measurement. Its 15 mm center height also gives you a defined reference point for holder and beam alignment.
- Path Length
- 0.4 mm
- Sample Volume (Nominal)
- 11 µL
- Closure Type
- Removable Cover Plate
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Demountable Cuvette |
| Measurement Mode | Fluorescence Spectroscopy; Solid/Powder Sample Measurement |
| Path Length | 0.4 mm |
| Z Height | 15 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 11 µL |
| External Dimensions | 9.5 × 1.5 × 25 mm |
| Cell Body Dimensions | 9.5 × 1.5 × 25 mm |
| Body Height | 25 mm |
| Base Dimensions | 9.5 × 1.5 mm |
| Internal Dimensions | 6 × 0.4 mm |
| Inner Diameter (ID) | 6 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Removable Cover Plate |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Demountable Cuvette; Accompanying closure |
Choose this option
Choose MQQMC015 when your method needs a very short fixed sample layer in a demountable format rather than a filled chamber. The shallow circular recess supports direct placement of a small liquid amount or prepared sample material, and the included cover plate lets you close the sample region after loading while keeping the sample area visible during preparation.
What makes this option different
- 0.4 mm optical path formed by the sample recess depth for short-path measurements.
- 6 mm diameter circular recess for direct loading and inspection before measurement.
- 15 mm center height for checking beam position in your holder or fixture.
- Removable cover plate included as part of the supplied cell set.
Structure and dimensions

Using this cell
Place the sample in the circular recess, then seat the cover plate carefully so the sample layer is formed across the recess without trapped particles or bubbles. This layout is useful when you want to see the sample area during loading instead of filling through a narrow opening.
Support both the body and the cover during handling and cleaning. Because this is a demountable design, it should be used in a suitable fixture that keeps the parts aligned during measurement; the removable cover is not a pressure seal.
First-use check
- Inspect the body plate, recess and cover plate surfaces for dust, chips or residue before assembly.
- Place the set in the holder or fixture and verify alignment at the 15 mm center height.
- Run a blank or background check after seating the cover, then repeat after loading the sample to confirm consistent positioning.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The stated 9.5 × 1.5 × 25 mm dimensions apply to the body plate. The cover plate is listed separately at 25 × 9.5 × 1.2 mm, so check your fixture for the assembled stack, clamping method and side clearance rather than relying on body dimensions alone.
The beam-center height is 15 mm from the cell bottom to the optical center. Check that your holder supports this center height and that the recess area aligns with the actual beam position used in your instrument.

Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. It is best suited to routine room-temperature aqueous samples and buffers. Avoid organic samples and organic cleaning solvents with this bonded assembly. If your method involves organic solvents or heated treatment, ask about a suitable Sintered or Molded alternative before ordering.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the body and cover gently, and avoid cleaning routines that may stress bonded areas or scratch the mating surfaces.
Included with this option
1 MQQMC015 demountable cuvette set with body and removable cover plate. The listed price is for one cell set.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz demountable cells for changes to path length, recess geometry, center height, external dimensions and fabrication. If you need this format to match an existing fluorescence holder or a solid-sample fixture, send a dimensioned drawing or labelled sketch and mark the dimensions and tolerances that matter to your setup.
Send a product-selection enquiry with SKU MQQMC015, your holder details, sample type, chemical conditions, quantity and delivery destination.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.










Reviews
There are no reviews yet.