(MQQSC022) Quartz Screw-Top Cuvette, 1 mm path, 260 µL nominal capacity, Angled Screw Neck

Weight50 g
SKU: MQQSC022

$419.00

In Stock

Quartz screw-top cuvette for UV/Vis work with a 1 mm optical path, Two-Way Light layout and an angled M6 threaded neck. Its 260 µL nominal capacity and slim 12.5 × 4.25 mm body suit installations that need a narrow rectangular optical section with top access through a threaded neck. Sold individually as 1 cuvette.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQSC022 is a JGS1 quartz screw-top cuvette for UV/Vis measurements with a 1 mm optical path, Two-Way Light transmission and an angled single threaded neck. This layout is useful when you need a narrow rectangular optical body but do not want the opening directly above the centerline of the cell. The 260 µL nominal capacity and slim 12.5 × 4.25 mm body help when holder space is limited around the optical section.

Path Length
1 mm
Sample Volume (Nominal)
260 µL
Opening Configuration
Single Threaded Neck

Selection Specifications

Product KindCuvette
Cell TypeScrew-Top Cuvette
Measurement ModeUV/Vis Spectroscopy
Path Length1 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)260 µL
External Dimensions12.5 × 4.25 × 38 mm
Body Height38 mm
Base Dimensions12.5 × 4.25 mm
MaterialQuartz
Material GradeJGS1
Closure TypeScrew Cap
Port ThreadM6
Fabrication MethodMolded 83
Opening ConfigurationSingle Threaded Neck
Closure ThreadM6
Pack Quantity1 Piece
Package Contents1 × Quartz Screw-Top Cuvette

Choose this option

Choose this option when your method uses a 1 mm path and your fixture is designed for a narrow rectangular cuvette body rather than a wider standard format. The angled M6 neck is the main selection feature here: it changes how you fill, close and access the cell above the optical body, so it should be checked against nearby clamps, covers and surrounding hardware.

What makes this option different

  • 1 mm optical path for methods that require a short transmission distance.
  • Two-Way Light configuration with two opposing optical faces for the measurement beam.
  • Angled single threaded neck with M6 closure thread, affecting top access and handling position.
  • Slim 12.5 × 4.25 mm body with 38 mm body height to the shoulder for compact holder layouts.

Using this cell

Fill and orient the cuvette so the 1 mm path is used consistently for both blank and sample measurements. Make sure the liquid fully covers the illuminated region, and remove visible bubbles before measurement.

Handle the cell by the non-optical surfaces where possible. Keep the two transmitting faces clean and free of dried residue, droplets and fingerprints, especially for work at lower UV wavelengths.

First-use check

  1. Inspect the optical faces and sample chamber for chips, residue or handling marks.
  2. Test holder fit and beam position with a suitable blank before running samples.
  3. Check that the angled neck area can be reached for filling and closure handling without disturbing the cuvette position.

Fit and optical alignment

View the English selection reference. Also available in the product gallery.

The optical body dimensions are 12.5 × 4.25 × 38 mm. Here, 38 mm is the body height to the shoulder, not a full assembled height with a cap, so check upper-neck clearance separately if your holder surrounds the top of the cell.

Z Height is not established for this SKU. If your spectrometer or holder depends on a specific beam-center height, verify that point before ordering rather than assuming fit from the body size alone.

The neck uses an M6 closure thread. If your setup requires a matching cap, confirm that it is included with your order.

English selection reference
Selection reference ↗

Solvents and cleaning

Molded 83 is the fabrication used for this cuvette. This type is commonly chosen for organic-solvent methods, but the exact chemical limits for this SKU are not established here, so suitability should be checked for your actual sample and cleaning conditions when exposure is aggressive, heated or prolonged.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning materials. Clean the optical faces gently with suitable non-abrasive tissue and a compatible cleaning liquid.

Included with this option

1 Quartz Screw-Top Cuvette. The listed price is for one cell.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a product-selection enquiry with SKU MQQSC022, your holder or instrument details, sample conditions and required quantity.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQSC022) Quartz Screw-Top Cuvette, 1 mm path, 260 µL nominal capacity, Angled Screw Neck”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare