(MQQMC009) Quartz Micro Cuvette, 10 mm path, 1.75 mL nominal capacity, 5 mm Sample Slit
$101.00
MQQMC009 combines a 10 mm optical path, 1.75 mL nominal capacity and 5 mm sample slit with an open top and a side access feature. This JGS1 quartz design provides the access geometry shown for this model, in Standard 80 adhesive-bonded construction for room-temperature aqueous work. Sold as one cell.
Description
MQQMC009 is a JGS1 quartz micro cuvette for UV/Vis measurements, combining a 10 mm optical path with a 1.75 mL nominal capacity in a compact square body. Its open-top format and side access feature make it useful when you need direct top filling but also need the side-entry arrangement shown for this model. The cell uses a Two-Way Light layout and a 5 mm sample slit.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.75 mL
- Opening Configuration
- Open Top with Side Access Feature
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top with Side Access Feature |
| Bottom Thickness | 4 mm |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Micro Cuvette |
Choose this option
Choose MQQMC009 when your method uses a 10 mm path and you want an upright micro cuvette with both top access and a defined side access feature. That combination can be helpful when your filling, sampling or handling routine depends on reaching the sample region from more than one direction, while still keeping the familiar square-body cuvette format for holder-based UV/Vis work.
What makes this option different
- 10 mm optical path in a micro cuvette format for methods built around this standard path length.
- Open top with side access feature for applications that need this specific sample-entry geometry.
- 5 mm sample slit as part of the stated sample-region layout for this SKU.
- Two-Way Light configuration for transmission through one opposing face pair.
Structure and dimensions

Using this cell
Fill the cell from the top and keep the optical direction consistent between blank and sample runs. If your procedure uses the side access feature during preparation or sampling, work carefully to keep the optical region fully covered and free of trapped bubbles before measurement.
The 1.75 mL figure is the nominal capacity of the cell. It is not a minimum working volume, so the practical fill level still depends on your beam position and measurement setup.
First-use check
- Inspect the optical faces, top opening and side access area for chips, particles or residue.
- Place the cell in your holder and confirm the intended optical orientation.
- Fill with a suitable blank and make sure the illuminated region is fully covered without bubbles.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The body dimensions are 12.5 × 12.5 × 45 mm, and these dimensions apply to the body only. Check holder clearance, top access space and the side-entry clearance in your instrument or fixture before ordering.
The 5 mm slit describes the sample region. The R1 annotation on the access drawing is a radius, not a 1 mm tubing bore or a specified needle gauge. Needle fit, septum use and pressure operation are not rated for this option. Z Height is not specified, and the 4 mm bottom thickness is not beam-height data. If your instrument has a fixed beam centre or a tight aperture, check the actual beam position against your holder arrangement before purchase.

Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. It is generally chosen for room-temperature water-based samples and buffer solutions.
Avoid organic samples and organic cleaning solvents with this adhesive-bonded cell. Keep hydrofluoric acid away from quartz, and avoid hot strong alkalis and abrasive cleaners. Clean the optical faces gently with non-abrasive optical tissue or a similar suitable lab wipe.
Included with this option
1 Quartz Micro Cuvette. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to dimensions, path length, volume, optical windows, Z Height, opening style and tolerances. Send a product-selection enquiry with SKU MQQMC009 if you need a different access geometry or holder fit.
For a modified JGS1 quartz version, send a labelled drawing, holder and beam details, sample and cleaning conditions, and target quantity. Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation.
Additional information
| Weight | 180 g |
|---|