(MQQMC019) Quartz Micro Cuvette, 0.4/10 mm paths, 140 µL nominal capacity, 0.4 mm Narrow Sample Region
$239.00
JGS1 quartz Micro Cuvette for fluorescence spectroscopy with a 0.4 mm optical path, 10 mm secondary path and Four-Way Light geometry. Its 140 µL nominal capacity and open-top format suit direct filling where the method depends on a narrow sample region with optical access from multiple sides. The listed price is for 1 piece.
Description
MQQMC019 is a JGS1 quartz Micro Cuvette for fluorescence spectroscopy with a 0.4 mm optical path, a 10 mm secondary path and Four-Way Light geometry. Its 140 µL nominal capacity and open-top body make it useful when the sample region is narrow but the optical arrangement needs access from more than one direction. This listing is sold as 1 piece.
- Path Length
- 0.4 mm / 10 mm (dual path)
- Sample Volume (Nominal)
- 140 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 0.4 mm / 10 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 140 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Micro Cuvette |
Choose this option
Choose MQQMC019 when your method is built around this exact 0.4/10 mm geometry rather than a single-path cell. The short 0.4 mm path and Four-Way Light layout are the main reasons to select it: they shape how the sample sits in the beam and how the cell is oriented in fluorescence work.
What makes this option different
- 0.4 mm optical path provides a very short transmission direction through the sample region.
- 10 mm secondary path makes this a dual-path geometry that should be matched to your measurement arrangement.
- Four-Way Light layout gives optical access from four sides for compatible fluorescence beam geometry.
- Open-top, 140 µL nominal capacity allows direct filling in a compact micro-volume format.
Structure and dimensions

Using this cell
Fill the cell carefully from the top and keep the measurement orientation consistent between blank and sample. In this kind of narrow-volume geometry, bubbles, droplets and small filling differences are more likely to affect the reading, so it helps to inspect the sample region before each run.
If your method depends on the 0.4 mm path, keep that optical direction the same throughout your sequence. Clean, dry outer faces are important for both the transmission direction and the side optical access used in a compatible fluorescence setup.
First-use check
- Inspect the optical faces and sample region for dust, residue or chips.
- Place the cuvette in the holder and verify beam access in the intended orientation with a suitable blank.
- Confirm that your actual fill level covers the required beam position in your chosen measurement direction.
Fit and optical alignment
The body dimensions are 12.5 × 12.5 × 45 mm, and they apply to the body only. Use them to check holder clearance and loading space, especially if your setup is tighter than a standard square cuvette position.
Z Height is not established for this SKU. The nominal capacity should also not be treated as a minimum working volume, so if your instrument depends on a specific beam height or a very specific fill level, review that point before ordering.
View the English selection reference.

Solvents and cleaning
This cuvette uses Standard 80 adhesive-bonded quartz construction. This type is usually selected for room-temperature water-based samples and buffer solutions.
Avoid organic samples and organic cleaning solvents with this construction. Do not use hydrofluoric acid with quartz, avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces gently with suitable non-abrasive lab wipes.
Included with this option
1 Quartz Micro Cuvette. The listed price is for one cuvette.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes involving optical path length, sample volume, outer dimensions, optical windows, Z Height, closure details and fabrication requirements. Send your drawing or holder information, the critical dimensions and tolerances, the measurement wavelength range, sample conditions and target quantity.
Contact us with SKU MQQMC019 if you need a modified version for a specific holder or optical arrangement.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.