(MQQFC049) Quartz Rectangular Sample Cell, 40 mm Path, 70 mL, Open at Both Ends
Description
MQQFC049 is a JGS1 quartz rectangular sample cell for setups that need a 40 mm optical path in a large open-ended chamber. The Four-Way Light layout and 70 mL nominal capacity make it useful when you need optical access from more than one side and want to build the cell body into your own holder, end support or sample-handling arrangement.
This is a cell body rather than a ready-connected flow assembly. With both ends open, you can plan filling, draining and end closure around your own fixture instead of working around a fixed cap or port design.
- Path Length
- 40 mm
- Sample Volume (Nominal)
- 70 mL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 40 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 70 mL |
| External Dimensions | 44 × 44 × 44 mm |
| Body Height | 44 mm |
| Base Dimensions | 44 × 44 mm |
| Internal Dimensions | 40 × 40 × 44 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFC049 when your method needs a stated 40 mm path together with a large rectangular chamber and access through both ends. It is a practical option for custom transmission or observation setups where the mounting, sealing and liquid-handling details will be defined by the hardware around the cell.
View the English selection reference. Also available in the product gallery. Group photographs illustrate other options in the series.
What makes this option different
- 40 mm optical path for methods built around this path length.
- Open at both ends for custom end support, sealing or sample transfer arrangements.
- Four-Way Light configuration for optical layouts that use access from more than one side.
- 70 mL nominal capacity in a large rectangular chamber for full-volume filling or other fixture-defined operating methods.
Structure and dimensions

Using this cell
Install the cell so the beam passes across the 40 mm path, and keep the same orientation for blank and sample. If you are working with liquids, set the filling, sealing and bubble-removal steps in the finished assembly before routine use, because the cell body itself does not include built-in closures or fluid connections.
The 70 mL figure is the nominal chamber capacity. It should not be treated as a minimum working volume, and any partial-fill, circulation or retained-liquid condition needs to be established in the completed holder or flow arrangement.
First-use check
- Inspect the optical faces, end edges and contact areas for chips, residue or handling damage.
- Check that the holder supports the body securely without twisting or point loading.
- Run a blank in the intended orientation and confirm that filling and bubble control are stable before measurement.
Fit and optical alignment
Use the 44 × 44 mm outer footprint and 44 mm body height to check holder clearance and support space. The internal 40 × 40 × 44 mm dimensions describe the chamber space only; they do not define the size of your holder opening, end seal or mounting contact area.
Z Height is not stated for this SKU, so beam-center fit should be checked in the actual fixture rather than assumed from the outer body size alone. Support the body evenly and avoid concentrated clamping force across the transmitting faces or end edges.

Solvents and cleaning
This cell is made from JGS1 quartz with a supplier-described powder-fused construction. For general fabrication background, see MQ Cuvette Fabrication Glossary.
Chemical limits for the complete working assembly are not established here, so solvent choice and cleaning method should be checked for the full mounted arrangement, including any seals or fittings you add. Keep hydrofluoric acid away from quartz, avoid hot strong alkalis and abrasive cleaning methods, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
1 rectangular sample cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different end arrangement, holder fit or optical layout, send your drawing or labelled sketch with the critical dimensions, path requirement, sample conditions and target quantity. For fit review, it is helpful to include holder details, beam position information, sealing approach and any liquid-handling requirements.
Send a product-selection enquiry with SKU MQQFC049 and your application details.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.