(MQQFC134) Quartz Flow Cell, 10 mm Path, 4 mL, Open Top and Four Side Ports
$377.00
JGS1 quartz flow cell with a 10 mm optical path, 4 mL nominal capacity and an open-top chamber. Four side tubes provide two connection sizes: two at 7 mm OD / 5 mm ID and two at 5 mm OD / 3 mm ID, each projecting 5 mm beyond the 12 × 12 × 50 mm body. Standard 80 adhesive-bonded construction for room-temperature aqueous methods; one cell supplied.
Description
MQQFC134 combines a 10 mm optical path with direct access through an open top and four lateral fluid connections. Its two tube sizes let you plan different connection points around a single sample chamber while retaining two opposing optical faces for transmission measurement.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 4 mL
- Opening Configuration
- Open Top with Four Side Connections
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 4 mL |
| External Dimensions | 12 × 12 × 50 mm |
| Cell Body Dimensions | 12 × 12 × 50 mm |
| External Dimensions Scope | Body Only |
| Body Height | 50 mm |
| Base Dimensions | 12 × 12 mm |
| Internal Dimensions | 10 × 10 × 49 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 4 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top with Four Side Connections |
| Port Layout | Left face, upper large tube as drawn; Left face, middle large tube as drawn; Left face, lower small tube as drawn; Opposite face, lower small tube as drawn |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose this format when your setup needs access to the chamber from above as well as several lateral connection points. The open top makes filling, inspection and rinsing accessible; the projecting glass tubes need support and clearance in your holder and tubing layout.
What makes this option different
- Four fluid ports in two sizes: two larger tubes are 7 mm OD / 5 mm ID and two smaller tubes are 5 mm OD / 3 mm ID. Each projects 5 mm beyond the body. Match your tubing and adapters to the individual port rather than treating all four as identical.
- Two optical faces: the optical path is 10 mm. The four fluid ports do not imply four optical windows or separate internal liquid circuits.
- Open-top chamber: direct sample access suits filling and visual inspection. This configuration does not provide an enclosed, pressure-rated flow system.
- Compact square body: the 12 × 12 mm footprint and 50 mm body height describe the cell body, excluding its lateral projections and any tubing you attach.
Using this cell
Support the body before fitting tubing so that connection forces do not load the glass side tubes. Plan the routing and function of each port for your own circuit; the connection arrangement alone does not assign inlet and outlet roles. Establish a working fill that covers the beam without bubbles. The stated 4 mL is nominal capacity, not a minimum working-volume specification.
First-use check
- Inspect the optical faces, open chamber and four glass tubes for damage or residue.
- Check holder seating and tubing clearance with the cell supported; fit connections without twisting or bending the glass tubes.
- Use a suitable blank at your measurement wavelength, remove bubbles from the optical region and use the same seating and orientation for blank and sample.
Fit and optical alignment
The body is 12 × 12 × 50 mm and the internal chamber is specified as 10 × 10 × 49 mm. Allow additional space for all four 5 mm tube projections, adapters and tubing bends. Check beam position against your instrument and holder; tube-centre offsets in a drawing are not a specified Z Height.
View the English selection reference.

Solvents and cleaning
Standard 80 is an adhesive-bonded quartz construction for routine room-temperature aqueous samples and buffers. Avoid organic sample solvents and organic cleaning agents on this bonded assembly. For an organic-solvent or heated method, review a suitable alternative construction before ordering.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Wipe exterior optical faces gently with non-abrasive optical tissue; check any tubing and adapter materials against your sample and cleaning conditions.
Included with this option
One quartz flow cell in the open-top, four-side-port configuration shown. The listed price is for one cell; no separate cap, tubing or adapters are stated as included.
Availability and ordering
Order this specification directly, or contact us to confirm current availability and dispatch timing for your quantity. For a required delivery date, check timing before checkout; preparation and production are separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects involving body dimensions, optical path, sample volume, windows, connections and fabrication requirements. Modified designs and prototype batches are quoted separately from this SKU. Send your drawing or labelled sketch, holder details, sample conditions and quantity through the contact page, and include MQQFC134.
Design notes for this configuration: Open-Top Quartz Flow Cell: Planning Direct Access beside the Tube Connections
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.