Site Navigation

(MQQFC133) Quartz Flow Cell, 10 mm Path, 4 mL, Extended Threads and PTFE Fittings

Weight100 g
SKU: MQQFC133

$408.00

In Stock

JGS1 quartz flow cell with a 10 mm optical path, 4 mL nominal capacity and four-sided optical access. Two extended threaded end blocks accept detachable PTFE fittings with 5 mm OD / 2 mm ID stubs. The quartz body is 56 × 12.5 × 12.5 mm; the shown assembled axial span is 92 mm. One cell in the detachable-fitting configuration shown.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC133 is a JGS1 quartz flow cell for fluorescence setups that need a 10 mm optical path and optical access from four sides. Its 4 mL nominal capacity, 10 × 10 × 40 mm internal channel and detachable PTFE fittings make it a practical choice when you want to plan the sample region, tubing route and holder clearance together.

The cell body uses opposed extended threaded ports, while the PTFE fittings are detachable rather than fixed to the quartz body. That can be useful when your installation needs a defined optical body size but you want flexibility in how the tubing is connected around it.

Path Length
10 mm
Sample Volume (Nominal)
4 mL
Opening Configuration
Two Opposed Extended Threaded Ports

Selection Specifications

Product KindFlow Cell
Cell TypeFlow Cell
Measurement ModeFluorescence Spectroscopy
Path Length10 mm
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)4 mL
External Dimensions12.5 × 12.5 × 56 mm
Cell Body Dimensions56 × 12.5 × 12.5 mm
External Dimensions ScopeBody Only
Base Dimensions12.5 × 12.5 mm
Internal Dimensions10 × 10 × 40 mm
MaterialQuartz
Material GradeJGS1
Port Count2
Tube Outer Diameter (OD)5 mm
Tube Inner Diameter (ID)2 mm
Opening ConfigurationTwo Opposed Extended Threaded Ports
Fitting MaterialPTFE
Detachable FittingsYes
Port LayoutExtended threaded end A, shown on the left; Opposite extended threaded end B, shown on the right
Pack Quantity1 Piece
Package Contents1 × Quartz Flow Cell

Choose this option

Choose MQQFC133 when your method uses a flowing sample and you need a straight 10 mm path through a long square sample channel. The four-sided optical access geometry supports fluorescence layouts with side optical access, and the opposed extended ports keep the fluid connections arranged inline at both ends of the cell.

What makes this option different

  • 10 mm optical path with four-sided optical access: suited to fluorescence layouts that use optical access on more than one side.
  • 10 × 10 × 40 mm internal channel: a long square sample region paired with 4 mL nominal capacity.
  • Two opposed extended threaded ports: connections are arranged at opposite ends of the quartz body.
  • Detachable PTFE fittings: fitting material is PTFE, with 5 mm outer diameter and 2 mm inner diameter connection dimensions shown.

Using this cell

The drawing marks an 8 mm extended threaded section. That is a length, not an M8 nominal thread designation. The 5 mm OD / 2 mm ID figures describe the PTFE fitting stubs, not a prescribed mating hose size. Check the connection method and support the quartz body while removing or refitting connectors.

Install the cell so the selected optical faces line up with your illumination and detection geometry, then connect the tubing with the quartz body properly supported. Fill the channel slowly and clear bubbles from the optical region before establishing the blank or background.

The 4 mL value is the nominal cell volume, not a minimum working volume. Pressure limits are not established here, so operating conditions should be reviewed for the complete assembled flow path.

First-use check

  1. Inspect the optical faces, internal channel and connection points before use.
  2. Check that the body is supported without loading the detachable fittings.
  3. Run a blank after filling and repeat it once bubbles and exterior droplets have been removed.

Fit and optical alignment

View the English selection reference.

The bare quartz body is 56 × 12.5 × 12.5 mm. The source drawing also shows a 92 mm assembled axial length, so your holder space should be checked for both the optical body and the full installed assembly with fittings.

Z Height is not established for this SKU. If your holder or instrument depends on a defined beam-center height, that point should be checked before ordering. Leave additional room for tubing approach and bend radius beyond the body length.

English selection reference
Selection reference ↗

Solvents and cleaning

The quartz body and removable PTFE fittings form separate wetted components. Select sample and cleaning conditions for the complete flow path, including any seals, tubing and adapters used in your setup. The green ring colour alone does not identify its elastomer material or chemical limits.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive materials, and review chemical exposure for the full assembly if your method involves aggressive liquids, heat or long contact time.

Included with this option

One quartz flow cell in the detachable-PTFE-fitting configuration shown. The listed price is for one cell; external tubing and supports are not stated as included.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We can review custom JGS1 quartz flow cells for changes to path length, channel size, external envelope, port arrangement and connection details. Please send your drawing or labelled sketch, holder information, sample conditions and required quantity.

Send a product enquiry and include SKU MQQFC133 with your application details.

Additional information

Weight100 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC133) Quartz Flow Cell, 10 mm Path, 4 mL, Extended Threads and PTFE Fittings”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar