Site Navigation

(MQQCU014) Quartz Standard Cuvette, 5 mm path, 0.5 mm Optical Walls, Pack of 2

Weight100 g
SKU: MQQCU014

$118.00

In Stock

MQQCU014 is a JGS1 quartz standard cuvette with a 5 mm optical path, Two-Way Light layout and an open top with a flat lid for UV/Vis measurements from 200 to 2500 nm. Its 1750 µL nominal capacity and slim 12.5 × 6 mm body help when you need a narrower rectangular cell format.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQCU014 is a JGS1 quartz standard cuvette for UV/Vis spectroscopy with a 5 mm optical path and Two-Way Light layout. The open-top body lets you fill the cell directly, while the flat lid covers the opening during routine handling. With a 1750 µL nominal capacity and a slim rectangular body, this option suits methods that need a shorter path in a narrower cell format.

Path Length
5 mm
Sample Volume (Nominal)
1.75 mL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeStandard Cuvette
Measurement ModeUV/Vis Spectroscopy
Path Length5 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)1.75 mL
External Dimensions12.5 × 6 × 45 mm
Body Height45 mm
Base Dimensions12.5 × 6 mm
MaterialQuartz
Material GradeJGS1
Closure TypeFlat Lid
Closure IncludedYes
Opening ConfigurationOpen Top
Sales Unitpack of 2
Package Contents2 × Quartz Standard Cuvette; Accompanying closures

Choose this option

Choose MQQCU014 when your method calls for a 5 mm path and you want direct top access for filling and cleaning. The quartz body is specified for UV/Vis use from 200 to 2500 nm, and the supplied flat lids let you cover the opening after filling without changing the basic open-top handling style.

What makes this option different

  • 5 mm optical path: for methods specified for this short fixed transmission distance.
  • Two-Way Light layout: intended for transmission measurements through the main opposing optical faces.
  • Open top with flat lid: direct access for pipetting, rinsing and inspection before the cell is covered.
  • 1750 µL nominal capacity: a compact sample region for this cell geometry, while nominal volume is not the same as minimum working fill.
  • Fused integrated construction: the joined body is rinsed as an assembly through the open top; the flat lid can be lifted away for pipette access.
  • Slim 12.5 × 6 mm body, 45 mm height: useful dimensions to check against holder width, slot depth and vertical clearance.
  • Pack of 2: the listed price covers two quartz cuvettes with accompanying closures.

Using this cell

Fill the cell from the top opening and place the flat lid after filling when you want the chamber covered during routine handling. Keep the optical faces clean and orient the cell the same way for blank and sample readings.

Before measurement, check that the liquid fully covers the part of the chamber used by your instrument beam. Remove visible bubbles from the optical path and wipe the outside faces carefully so droplets or fingerprints do not affect the reading.

First-use check

  1. Inspect the optical faces, top opening and lids for chips, dust or handling marks.
  2. Place each cell in your holder and confirm stable seating and correct beam direction through the intended faces.
  3. Run a blank in the same orientation you plan to use for the sample.

Fit and optical alignment

The external body size is 12.5 × 6 × 45 mm, so this cuvette can be useful where a narrower rectangular body helps with holder fit or side clearance. The 5 mm path is the optical dimension through the measurement direction; the slim body dimensions are separate fit checks and should be matched to your holder or slot.

Z Height is not established for this SKU, so beam-center fit should be checked from your holder drawing or an existing cell reference if that dimension is critical. View the English selection reference.

English selection reference
Selection reference ↗

Solvents and cleaning

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods.

Chemical compatibility for the complete assembled cell is not established here, so check your actual sample and cleaning conditions if they involve organic solvents, aggressive solutions, elevated temperature or long contact time. Clean the optical faces gently with non-abrasive optical tissue.

Included with this option

2 quartz standard cuvettes and accompanying closures. The listed price is for the pack of 2.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for requirements involving path length, capacity, external dimensions, optical windows, Z Height, closures and tolerance needs. Send your drawing or holder details, sample conditions, required quantity and delivery target through our contact page, and we can review a suitable custom option.

Additional information

Weight100 g

Reviews

There are no reviews yet.

Be the first to review “(MQQCU014) Quartz Standard Cuvette, 5 mm path, 0.5 mm Optical Walls, Pack of 2”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare