(MQQCU021) Quartz Flow Cell, 10 mm path, 600 µL nominal capacity, 5.3 mm Bottom Hole
$527.00
MQQCU021 is a JGS1 quartz flow cell with a 10 mm path, Three-Way Light geometry and 600 µL nominal capacity. Its 20 mm Z Height, two top fluid ports and 5.3 mm bottom bore suit compact fluorescence-related flow setups that need defined beam position and a separate bottom locating feature. Sold as 1 piece.
Description
MQQCU021 is a JGS1 quartz flow cell with a 10 mm path, Three-Way Light geometry and 600 µL nominal capacity. It combines two top fluid ports with a 5.3 mm bottom bore in a compact 12.5 × 12.5 × 45 mm body, making it useful for fluorescence-related flow setups that need a defined 20 mm beam-center height and a separate bottom support or locating feature.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 600 µL
- Opening Configuration
- Two Threaded Fluid Ports with Bottom Bore
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Three-Way Light |
| Z Height | 20 mm |
| Optical Window Dimensions | 3.5 × 17.5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 600 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Two Threaded Fluid Ports with Bottom Bore |
| Port Layout | Top connection at the left in the referenced original; Top connection at the right in the referenced original |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose this cell when your setup needs a compact square flow cell with top-access plumbing and a known 20 mm Z Height. The extra optical access of the Three-Way Light layout can suit fluorescence-related measurement geometry, while the bottom bore gives a separate mechanical feature to match to your holder or fixture.
What makes this option different
- Three-Way Light geometry adds side optical access beyond a simple two-face transmission layout.
- 20 mm Z Height gives a defined beam-center position for holder alignment.
- Two top threaded fluid ports plus a 5.3 mm bottom bore separate the fluid connection area from the bottom locating or mounting feature.
- 600 µL nominal capacity in a 12.5 × 12.5 × 45 mm body keeps the cell compact while retaining a 10 mm path.
Using this cell
Connect the two top ports as required by your flow circuit, with the cell body supported during installation. Fill slowly so the optical region is fully wetted, and inspect for bubbles before taking a blank or sample reading.
The bottom bore is a separate physical feature from the two fluid ports. Match it to your holder or locating arrangement, but do not treat it as a third fluid connection when planning the liquid line.
First-use check
- Inspect the windows, port openings and bottom bore for damage or residue.
- Check holder seating and verify beam alignment using the 20 mm Z Height.
- Fill with your blank, remove visible bubbles and confirm stable positioning before sample measurement.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The bare body measures 12.5 × 12.5 × 45 mm, and the optical window size is 3.5 × 17.5 mm. Leave extra space above the cell for fittings, tubing and turning clearance, because the body dimensions do not include added connection hardware.
Use the 20 mm Z Height as the alignment reference from the base to the beam center. The bottom bore is identified as 5.3 mm, so holder depth and locating details should be checked separately from the optical path and port positions.

Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. It is generally suited to room-temperature water-based samples and buffer systems. Avoid organic samples and organic cleaning solvents unless suitability has been checked for the complete assembly.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaners, and clean the optical faces gently with non-abrasive optical tissue. Pressure limits and detailed chemical limits are not specified here, so review the complete operating conditions before use in demanding service.
Included with this option
1 Quartz Flow Cell. The listed price is for 1 piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch together with holder details, sample conditions and the critical dimensions for your setup through the contact page, and reference MQQCU021.
Design notes for this configuration: 600 µL Quartz Microflow Cell: Aligning the Window, Tubes and Base
Additional information
| Weight | 250 g |
|---|
You must be logged in to post a review.