Site Navigation

(MQQMC025) Quartz Micro Cuvette, 30 mm path, 2.6 mL nominal capacity, 2.5 mm Slit

Weight80 g
SKU: MQQMC025

$156.00

In Stock

MQQMC025 combines a 30 mm optical path with a 2.5 mm sample slit and 2.6 mL nominal capacity in an open-top JGS1 quartz body. The 32 × 12 × 45 mm format differs from a 10 mm square-body cell. Standard 80 adhesive-bonded construction for room-temperature aqueous samples; sold as one cell.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQMC025 is a JGS1 quartz Micro Cuvette for UV/Vis spectroscopy with a 30 mm optical path, Two-Way Light layout and 2.6 mL nominal capacity. Its open-top body gives direct access for filling, while the 2.5 mm slit and 32 × 12 × 45 mm body make this a specific geometry choice for holders and beam setups that suit the format.

Path Length
30 mm
Sample Volume (Nominal)
2.6 mL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeMicro Cuvette
Measurement ModeUV/Vis Spectroscopy
Path Length30 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)2.6 mL
External Dimensions32 × 12 × 45 mm
Cell Body Dimensions12 × 32 × 45 mm
Body Height45 mm
Base Dimensions32 × 12 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodStandard 80
Opening ConfigurationOpen Top
Pack Quantity1 Piece
Package Contents1 × Quartz Micro Cuvette

Choose this option

Choose MQQMC025 when your method needs a 30 mm path in a compact quartz micro cell and you want direct top access to the sample chamber. This option is especially useful when you already know your holder can accept the narrow rectangular body and your beam position matches the optical region of this format.

What makes this option different

  • 30 mm optical path for methods that need a longer straight-through measurement path.
  • Open-top body for direct pipette access during filling and cleaning.
  • 2.5 mm sample slit identifies the narrow sample-region geometry separately from the 30 mm optical path.
  • 32 × 12 × 45 mm body to check against holder space and seating.
  • 2.6 mL nominal capacity in a compact micro-cuvette format.

Structure and dimensions

Open-top cell with a narrow sample region; 30 mm optical path.
Open-top cell with a narrow sample region; 30 mm optical path.Open image ↗

Using this cell

Fill from the open top and keep the measurement orientation consistent between blank and sample. Before reading, check for bubbles in the optical region and wipe off any droplets or fingerprints on the outside optical faces.

This is an open-top cell, so handling during filling and transfer matters. If your method uses a small fill volume, remember that nominal capacity is not the same as minimum working volume.

First-use check

  1. Inspect the optical faces and sample chamber for chips, residue or handling marks.
  2. Place the cell in the holder and verify that it seats securely without strain.
  3. Run a blank in the intended orientation and confirm that the beam passes through the optical region cleanly.

Fit and optical alignment

View the English selection reference.

The body measures 32 × 12 × 45 mm, with a 32 × 12 mm base. These are the listed dimensions, rather than a rounded 32.5 × 12.5 mm footprint. Check holder clearance, support surfaces and beam position carefully, especially if your instrument expects a specific beam-center height.

The 2.5 mm slit is not a pipette-opening size or a guaranteed clear optical aperture. Z Height is not listed for this option, so instrument fit should be checked from your holder and beam geometry rather than assumed from body height alone.

English selection reference
Selection reference ↗

Solvents and cleaning

Avoid organic samples and organic cleaning solvents with this adhesive-bonded cell.

This cell uses Standard 80 adhesive-bonded quartz construction. It is generally suited to room-temperature water-based samples and buffer solutions.

For an organic-solvent method, ask about an appropriate alternative construction rather than using this adhesive-bonded cell. Other aggressive liquids, elevated temperature and prolonged contact also need a review of the complete assembly. Keep hydrofluoric acid away from quartz, avoid hot strong alkalis, and clean with non-abrasive materials only.

Included with this option

1 Quartz Micro Cuvette.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We can discuss related JGS1 quartz versions for changes to path length, body dimensions, capacity, openings or other fit-critical details. If you need a different holder fit, please send the instrument or holder information, key dimensions, beam requirements and sample conditions through our contact page. Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation.

Additional information

Weight80 g

Reviews

There are no reviews yet.

Be the first to review “(MQQMC025) Quartz Micro Cuvette, 30 mm path, 2.6 mL nominal capacity, 2.5 mm Slit”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare