(MQQST008) Quartz Stoppered Cuvette, 8 mm path, 680 µL nominal capacity, Raised-Base Chamber
Description
MQQST008 is a JGS1 quartz stoppered cuvette for UV/Vis measurements with an 8 mm optical path, Four-Way Light access and a 680 µL nominal capacity. The 8 × 8 mm internal chamber and 5 mm top opening make it easier to judge how you will fill, cover and align the sample region before choosing this format. Its 10 × 10 mm base and 45 mm body height also give you a defined outer envelope to compare with your holder.
- Path Length
- 8 mm
- Sample Volume (Nominal)
- 680 µL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Stoppered Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 8 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 680 µL |
| External Dimensions | 10 × 10 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 10 × 10 mm |
| Internal Dimensions | 8 × 8 × 10.75 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Stoppered Cuvette; Accompanying closure |
Choose this option
Choose MQQST008 when your method uses an 8 mm path and you want a stoppered cell with direct top filling rather than an open chamber. The 680 µL nominal capacity and 8 × 8 mm internal chamber suit methods that need a defined small sample region, while the four-side optical access supports UV/Vis beam arrangements that use the specified transmission faces.
What makes this option different
- 8 mm optical path suits methods specified for this absorption length.
- 5 mm top opening with stopper format gives direct access from above for filling and rinsing, while also requiring enough clearance for insertion and removal.
- Four-Way Light configuration provides optical access through four side faces for the stated UV/Vis use.
- 680 µL nominal capacity pairs with a compact sample region rather than a large-volume chamber.
- 8 × 8 × 10.75 mm internal chamber helps you assess sample space and liquid coverage in the measurement region.
- Raised sample chamber sits above the lower support section. Align the beam with that chamber rather than with the full 45 mm body height.
Using this cell
Load through the 5 mm top opening, allowing liquid to reach the raised chamber without trapped bubbles. Seat the supplied stopper gently after filling and support the cell by its body during transfer. The closure covers the opening; no pressure or leak-tightness rating is specified. Keep the same orientation for blank and sample measurements so the beam passes through the same faces each time.
Fill high enough for your method to cover the illuminated region, then remove visible bubbles from the chamber and fingerprints from the outer optical faces. The 680 µL figure is the nominal capacity of the cell, not a stated minimum working volume.
First-use check
Inspect the chamber and optical faces for chips, residue or transit damage. Before routine measurements, test seating in your holder and run a blank to check beam alignment and liquid coverage with your intended measurement setup.
Fit and optical alignment
The outer body is listed as 10 × 10 × 45 mm, with a 10 × 10 mm base. That gives you a starting point for checking holder opening, insertion depth and vertical clearance around the stopper area.
The chamber measures 8 × 8 × 10.75 mm. The 11.25 mm lower segment and 23 mm upper segment shown in the drawing are component dimensions, not a stated beam-center height. Z Height is not established for this SKU, so do not assume a particular beam-center position from the overall height alone. If your instrument has a fixed optical axis or a tight holder, compare the holder geometry with the selection reference before ordering.
View the English selection reference.

Solvents and cleaning
This cuvette uses quartz material with a fused-integrated construction style, so sample choice and cleaning routine should be judged for the assembled cell rather than from quartz alone. If your work involves aggressive solvents, elevated temperature or long contact time, check the suitability of the complete assembly before use.
For general fabrication background, see cuvette fabrication methods. Keep hydrofluoric acid away from quartz, avoid hot strong alkalis, and clean optical faces gently with non-abrasive optical tissue or another suitable soft wipe.
Included with this option
1 Quartz Stoppered Cuvette with accompanying closure. The listed price is for one cell.
Availability and ordering
Order this listed specification directly, or ask about current availability and dispatch. If your delivery date is important, ask before checkout; preparation or production time is separate from transit and customs clearance.
Discuss a custom version
If you need a different path length, chamber size, outer envelope or closure arrangement, send a drawing or describe the change you need. Include any holder limits, beam position requirements and sample conditions that matter to your application.
We coordinate custom JGS1 quartz production. Prototype batches typically involve 2–4 cells; feasibility, final specifications, quantity, price and production time are confirmed in the project quotation.
Additional information
| Weight | 120 g |
|---|
You must be logged in to post a review.









Reviews