(C012SS2) Quartz Stoppered Cuvette, 1 mm Path, 350 µL
Original price was: $228.00.$206.00Current price is: $206.00.
C012SS2 is a quartz stoppered cuvette with a 1 mm optical path, Two-Way Light geometry and 350 µL nominal capacity. The narrow path and compact stoppered body suit transmission methods that need a short path in a covered sample cell. Supplied as 1 cuvette with stopper included.
Description
C012SS2 is a quartz stoppered cuvette built around a 1 mm optical path in a compact body. Its 350 µL nominal capacity and covered top make it useful when your method calls for a short transmission distance and you want to fill the cell, seat the stopper and handle the sample in a small-format cuvette. This option is supplied as 1 cuvette with stopper included.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Stoppered Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 1 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 3.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 3.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Base Dimensions | 12.5 × 3.5 mm |
| Material | Quartz |
| Closure Type | Stopper |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
Choose this option
Choose C012SS2 when the key requirement is a short-path quartz cell in a stoppered format rather than an open-top chamber. The 1 mm path is the main selection point for concentrated or strongly absorbing samples that are measured by straight transmission, while the 350 µL nominal capacity keeps the sample region compact. The stopper covers the opening after filling, which is useful for routine handling and measurement where you do not want the sample region left open.
What makes this option different
- 1 mm optical path for methods that specify a short transmission distance.
- 350 µL nominal capacity in a compact sample chamber.
- Stoppered access so the sample is filled from the top and then covered with the supplied stopper.
- Two-Way Light layout for transmission through two opposite optical faces.
- 12.5 × 3.5 × 45 mm uncapped body for checking holder width, depth and vertical clearance around the cell body.
Using this cell
Fill from the top and make sure the liquid level covers the beam region used by your instrument before inserting the stopper. Remove visible bubbles and keep the same cell orientation for blank and sample measurements so the optical path is used consistently.
Handle the cuvette by the non-optical surfaces where possible. Insert the stopper gently into a clean opening; this is a covered sample cell, not a pressure-rated assembly.
First-use check
- Inspect the optical faces and stopper seating area for chips, residue or particles.
- Rinse with a cleaning liquid suitable for your method.
- Test-fit the uncapped cell body in your holder without forcing it.
- Run a blank in the same orientation you plan to use for the sample.
Fit and optical alignment
The uncapped cell body is 12.5 × 3.5 × 45 mm, with the stopper excluded from that height. The slim 3.5 mm body is the main fit detail if your holder or surrounding hardware has limited side clearance.
This is a Two-Way Light cuvette, so it is intended for a beam passing straight through two opposite optical faces. Z Height is not stated for this SKU, so if your instrument depends on a fixed beam-center height, check that requirement separately rather than relying on the external body size alone.
Solvents and cleaning
This cuvette is listed with Molded 83 fabrication. In MQ selection terms, that fabrication is commonly chosen for methods that may involve organic solvents or temperature-controlled use, but the exact chemical limits for this assembled cuvette-and-stopper combination are not stated here. If your sample or cleaning routine is aggressive or involves long contact time, check suitability for the complete assembly.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch, together with holder information, sample conditions and target quantity. For custom enquiries, please contact us and quote part number C012SS2.
Additional information
| Weight | 30 g |
|---|---|
| Dimensions | 0.35 × 1.25 × 4.5 mm |
You must be logged in to post a review.