
250 mL Quartz Flask with an Internal Dip Tube: Following the Sample Route
CUSTOM DESIGN GUIDE · MQM370
The MQM370 reference shows a nominal 250 mL quartz flask with a side connection continuing into an internal dip tube toward the base. The internal endpoint is its most useful distinction from a plain conical flask. A proposed sample route needs to account for both the outer connection and that inner tube.

Use and purpose · Specifications · In practice · Custom example · Buy or enquire
Follow the side connection into the vessel
The outside sidearm is only one end of the route. Inside, the tube extends down toward the base, placing its opening in a different region from a sidearm that ends near the upper wall. That distinction matters when planning where a line meets the contents.
For a proposed liquid-transfer or sampling arrangement, the tube endpoint can be shown relative to the working level and vessel base. For a proposed gas line, the same relationship determines where the line approaches the liquid. These are design examples, not assigned operating duties for the listed flask.
MQM370 configuration
The main opening and side line need different access
The main opening is approached from above, while a connected line occupies space beside the conical body. A complete layout shows the mating upper part, side connector and the support carrying the vessel.
The internal tube also occupies part of the sample space. Its position belongs in the vessel section alongside any inserted component. An outer view alone can miss that relationship, especially when a tool or accessory enters through the main opening.
Capacity is only one part of the selection
The nominal 250 mL value identifies the reference vessel. The useful working level follows the proposed process and the internal endpoint. A request based only on a larger or smaller capacity leaves the important tube relationship undefined.
The product is listed as a filtering flask, but the family name does not establish a vacuum or pressure rating. The connected system needs its own operating specification. The geometry can be described first without turning the visible sidearm into an unsupported performance claim.
A custom example: place the tube opening at the required sample level
ILLUSTRATIVE DESIGN EXAMPLE
Suppose the vessel format suits a station, but the sample route needs to meet the contents at a different height. A proposed version can retain the main body and define the internal endpoint and outside line direction together. The section then shows the working liquid level, bottom clearance and any upper accessory.
Order the listed configuration or discuss a change
View MQM370 and current pricing. For a custom version, send a labelled sketch that separates the features to retain from the changes you want.
For a version based on MQM370, show the main mating opening, side-line approach and desired internal endpoint. Include the working level, sample and operating conditions, support outline, quantity, destination and requested date.





Recent Comments