(C1002CS) Quartz Standard Cuvette, 100 mm Path, 35 mL
Original price was: $48.00.$44.00Current price is: $44.00.
C1002CS combines a 100 mm optical path with a 35 mL nominal chamber for UV/Vis methods that require a long liquid path. Direct open-top access makes filling and visual checks straightforward, while the accompanying PTFE cover fits over the opening during routine handling. This ordinary option is intended for neutral samples.
Description
C1002CS is a JGS1 quartz standard cuvette for UV/Vis measurements that require a 100 mm optical path in a rectangular cell. Its 35 mL nominal capacity suits a long liquid sample region, while the open top gives direct access for filling, inspection and rinsing. A PTFE cover is included, and the listed 12.5 × 102.5 × 45 mm dimensions apply to the uncapped cell body.
- Path Length
- 100 mm
- Sample Volume (Nominal)
- 35 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 100 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 35 mL |
| External Dimensions | 12.5 × 102.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 102.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Material | PTFE |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C1002CS when your method is written for a 100 mm path length and your holder can accommodate the longer cuvette body. The open-top format is practical when you need direct access to load and inspect the sample, and the PTFE cover can be placed over the opening during routine handling. This option is intended for neutral samples.
What makes this option different
- 100 mm optical path for methods that use a long fixed path length in a standard rectangular cuvette.
- Two-Way Light layout for straight through-beam UV/Vis measurements across opposing optical faces.
- 35 mL nominal capacity matched to this long-path cell format; nominal capacity is not the same as minimum working fill.
- Open-top access for direct filling, sample inspection and rinsing from above.
- PTFE cover included to cover the opening during ordinary handling, without turning the cell into a sealed or pressure-rated assembly.
- Uncapped body dimensions of 12.5 × 102.5 × 45 mm for checking holder length and top clearance.
Using this cell
Fill the cell from the top and make sure the liquid level fully covers the beam during measurement. If bubbles are present in the optical path, let them clear before reading. Handle the cell by the non-optical surfaces to keep the light path clean.
The PTFE cover is useful when you want to cover the opening between filling and measurement or during ordinary bench handling. It is a cover for the open top, not a pressure closure or a stated leak-tight assembly.
First-use check
- Inspect the optical faces for dust, residue or transport marks.
- Test the dry fit in your holder before filling.
- Run a blank with the liquid used in your method.
- Check that the filled sample level fully covers the beam in the measurement position.
Fit and optical alignment
The recorded external dimensions describe the uncapped body only. In practice, the 100 mm path length means you should check both holder clearance for the body length and the vertical space above the opening if you plan to use the cover in place.
Z Height is not established for this SKU. If your instrument or holder depends on a defined beam-center height, confirm that requirement separately rather than relying on the outer body size alone.
Solvents and cleaning
This ordinary option is intended for neutral samples. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods.
For general fabrication guidance, see Compare fabrication methods. Clean with a gentle, non-abrasive routine that matches your sample chemistry.
Included with this option
The selected C1002CS option includes a PTFE cover. Please check the current sale quantity for this listing if you need a specific number of cells.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz requirements related to dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication. Send a dimensioned drawing or labelled sketch, together with your holder or instrument details, critical dimensions, sample chemistry and target quantity. Prototype batches typically involve 2–4 cells, with feasibility, price and production time confirmed for the project. Discuss your requirements.
Additional information
| Weight | 100 g |
|---|