(C0.52CF1) Quartz Standard Cuvette, 0.5 mm Path, 170 µL
Original price was: $237.00.$214.00Current price is: $214.00.
C0.52CF1 is a quartz standard cuvette with a 0.5 mm optical path, 170 µL nominal capacity and an open-top body with no closure. This combination suits short-path work where you want direct pipette access to the sample region and a compact 3 × 12.5 × 45 mm body for holder-fit checks.
Description
C0.52CF1 is a quartz standard cuvette built around a 0.5 mm optical path and a 170 µL nominal volume. Its open-top, no-closure format gives direct access to the sample chamber for filling, rinsing and visual inspection, while the 3 × 12.5 × 45 mm body helps you check holder space before ordering. This is a useful choice when your method needs a very short path in a simple top-access cell rather than a capped or connected assembly.
- Path Length
- 0.5 mm
- Sample Volume (Nominal)
- 170 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 0.5 mm |
| Sample Volume (Nominal) | 170 µL |
| External Dimensions | 3 × 12.5 × 45 mm |
| Cell Body Dimensions | 3 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Closure Type | No Closure |
| Closure Included | No |
| Fabrication Method | Molded 0.01 |
| Opening Configuration | Open Top |
Choose this option
Choose C0.52CF1 when the key requirement is a 0.5 mm path with unrestricted top access. The open body is convenient for pipetting small fills and checking the liquid directly in the chamber, and the 170 µL nominal capacity keeps this short-path format within a compact standard-style cuvette body. Because there is no closure, it is best suited to methods that do not require a sealed top during use.
What makes this option different
- 0.5 mm optical path for methods that specifically call for a very short transmission path.
- 170 µL nominal capacity in this exact path/body combination, which helps when your method uses a small sample region but still needs a standard cuvette form.
- Open-top access for direct pipetting, rinsing and visual checking of the liquid level before measurement.
- No closure supplied, so the top remains unobstructed and you do not need to allow for lid handling during filling.
- Molded 0.01 fabrication, a useful option when your selection is being made not only by path length but also by the fabrication route used for this exact cell version.
- 3 × 12.5 × 45 mm body dimensions for checking holder slot fit and surrounding clearance.
Using this cell
Fill the cell from the top and make sure the liquid covers the beam region used by your instrument. Because the cell has a short path and a small nominal volume, filling should be done carefully to avoid trapped bubbles in the optical area.
The open top makes this cell easy to rinse between samples and easy to inspect before a reading. It is better suited to bench handling and direct loading than to applications that need a covered, leak-resistant or pressure-handled top.
First-use check
- Inspect the optical faces and inner chamber for dust or shipping residue.
- Place the empty cell in the holder to confirm stable seating.
- Run a blank after filling to confirm that the beam passes cleanly through the intended sample region.
Fit and optical alignment
The stated 3 × 12.5 × 45 mm dimensions apply to the body only. Use them to check holder seating, slot width and physical clearance around the cuvette position.
Z Height is not stated for this SKU. If your instrument has a fixed beam-center height or a holder designed around a defined beam position, check that requirement directly rather than assuming fit from overall body height.
Solvents and cleaning
Molded 0.01 is the option to consider when your method calls for closely specified optical-path precision. For the 0.5 mm path on this cell, agree the required tolerance and measurement conditions for the order.
For practical use, that means fabrication choice may be part of your selection when you are standardising not only the geometry of the cuvette but also the build type used in your method or purchasing specification.
Chemical limits for this exact SKU are not established here. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and clean the optical faces gently with non-abrasive optical tissue and a suitable liquid for your method.
Included with this option
The selected item is the C0.52CF1 open-top cuvette body without a closure. Package quantity is not stated here and should be checked on the selected sales option if piece count matters for your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; feasibility, final specifications, quantity, MOQ, price and production time are confirmed in the project quotation. Discuss your requirements and quote part number C0.52CF1.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.