(C052CF1) Quartz Standard Cuvette, 5 mm Path, 1.75 mL

Weight30 g
SKU: C052CF1

Original price was: $95.00.Current price is: $86.00.

In Stock

C052CF1 is a JGS1 quartz standard cuvette with a 5 mm optical path for UV/Vis transmission measurements. Its Two-Way Light layout, 1.75 mL nominal capacity and PTFE lid suit routine top filling and covered handling, while the stated 12.5 × 7.5 × 45 mm dimensions apply to the uncapped cell body.

In Stock
Add to Wishlist
Add to Wishlist
SKU: C052CF1 Categories: , , Brand:
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

C052CF1 is a JGS1 quartz standard cuvette for UV/Vis work with a 5 mm optical path and a rectangular open-top body. Its Two-Way Light layout supports straightforward transmission measurements, and the 1.75 mL nominal capacity gives you a clear scale for preparing and filling the sample region. A PTFE lid is included, while the published 12.5 × 7.5 × 45 mm dimensions apply to the uncapped cell body only.

Path Length
5 mm
Sample Volume (Nominal)
1.75 mL
Closure Type
Lid

Selection Specifications

Product KindCuvette
Cell TypeStandard Cuvette
Measurement ModeUV/Vis Spectroscopy
Path Length5 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)1.75 mL
External Dimensions12.5 × 7.5 × 45 mm
Uncapped Cell Dimensions12.5 × 7.5 × 45 mm
External Dimensions ScopeUncapped Cell
MaterialQuartz
Material GradeJGS1
Closure TypeLid
Closure MaterialPTFE
Closure IncludedYes
Fabrication MethodMolded 0.01

Choose this option

Choose C052CF1 when your method calls for a 5 mm path in a compact rectangular quartz cell with direct top access. The open body and separate lid make filling, covering and routine handling simple, and the uncapped body dimensions help when holder space is limited or overhead clearance needs to be considered separately.

What makes this option different

  • 5 mm optical path: suited to methods built around this transmission distance rather than a longer standard path.
  • Two-Way Light layout: use the opposing optical faces as the transmission axis and keep the same orientation for blank and sample.
  • 1.75 mL nominal capacity: large enough for routine filling while still keeping the sample region at a defined compact scale.
  • PTFE lid: covers the opening after filling, so you should allow clearance above the cell for placement and removal.
  • Uncapped body dimensions stated separately: the listed 12.5 × 7.5 × 45 mm size helps you check body fit without assuming lid clearance is included.
  • Molded 0.01 designation: relevant when your order depends on a closely specified optical path and the required tolerance needs to be agreed for the application.

Using this cell

Fill the cell from the top and place the lid after sample preparation if your procedure calls for the opening to be covered during handling. Hold the cuvette by the non-optical sides and keep the transmission faces clean and dry before measurement.

Use a consistent orientation for blank and sample readings. The 1.75 mL figure is the nominal capacity of the cell, not a minimum working volume, so the liquid level still needs to cover the actual beam region during measurement.

First-use check

  1. Inspect the quartz body and lid for visible chips, residue or distortion.
  2. Rinse with a suitable liquid for your method before first use.
  3. Place the uncapped body in the holder and confirm that it seats correctly.
  4. Fill the cell, remove visible bubbles and verify that the sample covers the measurement region.

Fit and optical alignment

The published external dimensions are 12.5 × 7.5 × 45 mm for the uncapped body. Use those dimensions to check fit in holders, clamps or accessory spaces that limit body width, depth or insertion height.

Z Height is not available for this SKU. If your instrument or holder depends on a specific beam-center height, check that point before ordering. If there is a cover, top clamp or other structure above the cell position, leave extra room for the PTFE lid because it is outside the stated body dimensions.

Solvents and cleaning

Molded 0.01 is the option to consider when your method calls for closely specified optical-path precision. For the 5 mm path on this cell, agree the required tolerance and measurement conditions for the order.

This quartz cuvette is intended for UV/Vis use, but the chemical limits for the complete body-and-lid assembly are not established here. If your samples or cleaning routine involve aggressive solvents or reagents, check suitability for the full assembly under your actual concentration, temperature and contact-time conditions before use.

Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with suitable laboratory materials. For general fabrication background, see https://machinedquartz.com/fabrication-method-of-cuvettes/.

Included with this option

This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application through https://machinedquartz.com/contact/. Please also include your application details and part number C052CF1. Prototype batches typically involve 2–4 cells; the final quantity, feasibility, specifications, price and production time are confirmed in the project quotation.

Additional information

Weight30 g

Reviews

There are no reviews yet.

Be the first to review “(C052CF1) Quartz Standard Cuvette, 5 mm Path, 1.75 mL”

You may also like…

10%
Quartz 50mm Standard Cuvette, 17.5ml, Two-way Light, PTFE Cap, Pack of Two, C502CE2

Quartz 50mm Standard Cuvette, 17.5ml, Two-way Light, PTFE Cap, Pack of Two, C502CE2

100 g
In Stock
Original price was: $409.00.Current price is: $369.00.
Add to Wishlist
Add to Wishlist
10%
(C202CE) Quartz Standard Cuvette, 20 mm Path, 7 mL

(C202CE) Quartz Standard Cuvette, 20 mm Path, 7 mL

100 g
In Stock
Original price was: $181.00.Current price is: $163.00.
Add to Wishlist
Add to Wishlist
10%
(C502CL) Quartz Large-Window Cuvette, 10 mm Path

(C502CL) Quartz Large-Window Cuvette, 10 mm Path

100 g
In Stock
Original price was: $142.00.Current price is: $128.00.
Add to Wishlist
Add to Wishlist
10%
Quartz 20mm Standard Cuvette, 7ml, Molded 83, Two-way Light, PTFE Cap, Pack of Two, C202CE5

Quartz 20mm Standard Cuvette, 7ml, Molded 83, Two-way Light, PTFE Cap, Pack of Two, C202CE5

100 g
In Stock
Original price was: $181.00.Current price is: $163.00.
Add to Wishlist
Add to Wishlist
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare