(C104TE) Quartz Screw-Top Cuvette, 10 mm Path
Original price was: $171.00.$154.00Current price is: $154.00.
C104TE is a quartz screw-top cuvette for fluorescence spectroscopy with a 10 mm optical path and Four-Way Light layout. It provides side optical access around the sample in a closed cell format rather than an open-top chamber. Supplied as 1 cuvette.
Description
C104TE is a quartz screw-top cuvette for fluorescence spectroscopy with a 10 mm optical path and Four-Way Light configuration. It suits methods that need optical access from four sides around the sample while using a closed cell format instead of an open-top chamber. This sales option is supplied as 1 cuvette.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 3.5 mL |
| Material | Quartz |
| Closure Type | Screw Cap |
| Fabrication Method | Molded 83 |
Choose this option
Choose C104TE when your fluorescence setup uses a 10 mm path and benefits from side optical access on four faces of the cell. The screw-top format gives direct top filling followed by closed-sample handling during measurement, which can be useful when you do not want the sample region left open in use. Molded 83 fabrication also makes this a relevant option to consider for methods that may involve organic-solvent handling or heated measurement conditions, subject to the full assembly and actual chemicals used.
What makes this option different
- 10 mm optical path suits methods built around a 1 cm measurement length.
- Four-Way Light configuration provides optical access from four sides for supported fluorescence geometries.
- Screw-top cell format allows direct filling from the top before measurement in a closed cell arrangement.
- Molded 83 fabrication is a useful selection point when your workflow may involve organic solvents or heated use, with final suitability depending on the complete assembly and conditions.
- Single-cuvette sale unit preserves the current MQ offer as 1 cuvette rather than a supplier multi-pack.
Using this cell
Fill the cuvette so the liquid covers the beam area used by your instrument, then seat the screw closure arrangement before measurement. Keep the optical faces clean and free from droplets, residue and fingerprints, and check for bubbles before placing the cell in the holder.
If your method depends on orientation, use the same position for blank and sample runs. Hold the cell by non-optical surfaces during filling and loading.
First-use check
Inspect the optical faces and threaded opening for chips, dust or packing residue. Rinse with a suitable liquid for your method, then run a simple blank check to confirm that the sample region sits correctly in the beam and that the closure seats evenly.
Fit and optical alignment
Check the holder opening, compartment clearance and beam position before ordering, especially if your instrument has limited space above the cell. A screw-top cuvette needs top clearance around the closure area, which can matter in enclosed compartments and close-fitting holders.
Z Height is not listed for this item, and no customer-ready outer dimension set is established here. If your holder uses a fixed beam center or tight fit geometry, confirm the required clearance and beam height before purchase.
Solvents and cleaning
Molded 83 is the fabrication type recorded for this cuvette. This fabrication is commonly chosen for methods involving organic solvents or heated measurement conditions, but compatibility still depends on the complete assembly and your actual liquid, concentration, temperature and contact time.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Rinse promptly after use and wipe the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
Price is for 1 cuvette, C104TE. Package contents beyond the single-cuvette sale unit are not listed here.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch, together with instrument or holder details, critical dimensions, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; final feasibility, specifications, price and production time are confirmed in the project quotation. Discuss your requirements and quote part number C104TE.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.