(C032WS) Quartz Large-Window Cuvette, 3 mm Path, 8 mL
Original price was: $218.00.$197.00Current price is: $197.00.
C032WS is a JGS1 quartz large-window cuvette with a 3 mm optical path, a two-way light layout and 8 mL nominal capacity for UV/Vis measurements. Its open-top chamber gives direct access for filling and rinsing, and the 42 × 5 × 72 mm body is useful where holder width is limited.
Description
C032WS is a JGS1 quartz large-window cuvette for UV/Vis measurements with a 3 mm optical path and 8 mL nominal capacity. Its open-top design gives direct access to the sample chamber for filling, rinsing and visual checking, while the slim 5 mm body width helps when side clearance in the holder is tight.
This is a two-way light cell with a 42 × 5 × 72 mm body and 1 mm stated wall thickness. The combination of a short optical path, a tall open body and direct top access makes it a practical choice when you want a manually filled quartz cell and need to check the body size against the holder space.
- Path Length
- 3 mm
- Sample Volume (Nominal)
- 8 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Large-Window Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 3 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 8 mL |
| External Dimensions | 42 × 5 × 72 mm |
| Cell Body Dimensions | 42 × 5 × 72 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
| Wall Thickness | 1 mm |
Choose this option
Choose C032WS when your method needs a 3 mm transmission path in an open-top quartz cell rather than a closed or threaded format. The 8 mL nominal capacity suits routine manual loading, blank exchange and rinsing from above, and the narrow 5 mm body width is worth checking where holder slot width or side clearance is limited.
What makes this option different
- Open-top sample chamber for direct filling, emptying and rinsing from above.
- 3 mm optical path for UV/Vis transmission work in a large-window cuvette body.
- Two-way light layout for straightforward transmission measurements across the stated path.
- 8 mL nominal capacity in a tall, narrow body: check liquid coverage at the instrument beam height rather than treating capacity as a minimum working fill.
- JGS1 quartz material with a stated 200–2500 nm application range.
- Standard 80 adhesive-bonded construction: use for routine room-temperature aqueous work; choose rinse liquids that respect the bonded joints and avoid organic solvents.
Using this cell
Fill the cell from the open top and use a liquid level that fully covers the beam region used by your instrument. The open chamber makes it easy to pipette in sample, pour out contents and rinse between blank and sample runs.
Keep the same orientation for blank and sample readings, and remove visible bubbles before measurement. Handle the cuvette by the non-optical sides where possible, and avoid touching the transmission faces.
First-use check
Inspect the chamber and optical faces for dust, chips or packing residue before use. Rinse with a suitable liquid for your method, then run a blank and make sure the cell sits squarely in the holder and the filled sample covers the measurement region.
Fit and optical alignment
The stated 42 × 5 × 72 mm dimensions apply to the body. Check this body size against your holder slot, side clearance and vertical support, especially if the cell must sit in a narrow opening.
Z Height is not stated for this cuvette, so beam-center position should not be assumed from the outer dimensions alone. If your instrument uses a fixed beam height or a tightly defined holder position, confirm that requirement before ordering.
Solvents and cleaning
Standard 80 here is an adhesive-bonded quartz construction. It is commonly selected for routine water-based samples and buffers at room temperature. Avoid organic sample solvents and organic cleaning agents with this construction.
If your method involves organic solvents, ask about a more suitable Sintered or Molded alternative. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with an optical-safe, non-abrasive tissue.
Included with this option
The listed price is for 1 C032WS cuvette. Confirm any required closure or additional accessories before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to dimensions, optical path length, sample volume, optical windows, Z Height, closures, connections and tolerances. Send a dimensioned drawing or labelled sketch together with your holder or instrument details, the critical dimensions, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation. Discuss your requirements.
Design notes for this configuration: 3 mm Broad Quartz Cuvette: A Short Path Without a Small Chamber
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.