(C304WS) Quartz Flow Cell, 10 mm / 30 mm (dual path) Path, 10.5 mL
Original price was: $802.00.$722.00Current price is: $722.00.
C304WS is a JGS1 quartz flow cell with 10 mm and 30 mm stated optical paths, Four-Way Light access and a 10.5 mL nominal capacity. Two opposed quartz fluid tubes with 5 mm OD and 3 mm ID help you plan the cell body and line connection together. Sold as 1 piece.
Description
C304WS is a JGS1 quartz flow cell for fluorescence work that uses a larger flow chamber and two stated optical path directions in one body. Its 10 mm / 30 mm dual-path layout, Four-Way Light geometry and 10.5 mL nominal capacity make it useful when you need multi-side optical access and a straight opposed-tube connection arrangement in the same assembly.
- Path Length
- 10 mm / 30 mm (dual path)
- Sample Volume (Nominal)
- 10.5 mL
- Opening Configuration
- Two Opposed Fluid Tubes
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm / 30 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 10.5 mL |
| External Dimensions | 76 × 12.5 × 32.5 mm |
| Cell Body Dimensions | 35 × 12.5 × 32.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 5 mm |
| Tube Inner Diameter (ID) | 3 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | Two Opposed Fluid Tubes |
| Wall Thickness | 1.25 mm |
Choose this option
Choose C304WS when your setup needs this dual-path flow-cell format rather than a single-path body. The combination of a larger nominal chamber, four optical sides and opposed end tubes suits installations where the cell must fit into both the optical layout and the liquid-handling layout at the same time.
What makes this option different
- 10 mm / 30 mm dual path gives two stated optical path directions within one cell body.
- Four-Way Light geometry provides optical access from multiple sides for fluorescence arrangements.
- 10.5 mL nominal capacity supports methods built around a larger filled cell volume.
- Two opposed quartz tubes, 5 mm OD / 3 mm ID provide a defined straight-through connection layout.
Using this cell
Support the cell by the main body during installation and connect the two opposed tubes without twisting or side-loading them. Fill gradually and check the illuminated region before measurement so that bubbles or incomplete wetting do not remain in the optical area.
The 10.5 mL figure is the nominal cell volume. It is not a stated minimum working volume, and it does not describe the total volume of any attached tubing or the rest of the fluid circuit.
No pressure limit is stated for this SKU. If your method involves pressurized flow, please review the full connection and operating conditions before use.
First-use check
- Inspect the optical faces and both tube ends for chips, dust or handling residue.
- Place the cell in the intended holder and confirm that the body and tube span have enough clearance.
- Fill with a suitable blank, remove visible bubbles from the illuminated region and then run the measurement in the same orientation.
Fit and optical alignment
The overall span is 76 × 12.5 × 32.5 mm, while the optical body itself is 35 × 12.5 × 32.5 mm. This matters when you are checking holder space, because the body fit and the full installed length with projecting tubes are different.
Z Height is not listed for this cell. If your holder or fluorometer requires a defined beam-center height, check that separately rather than using the overall height as a substitute.
The two end tubes are shown as opposed connections, but no inlet or outlet role is assigned. Plan flow direction according to your own tubing layout and fixture design.
Solvents and cleaning
This cell is listed as Molded 83. This fabrication type is commonly chosen for methods involving organic solvents and temperature-related applications, but suitability still depends on the complete wetted assembly and your actual liquid conditions.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning materials, and clean the optical faces gently with non-abrasive optical tissue or another suitable lint-free material.
Included with this option
1 flow cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects for changes to path length, chamber volume, body dimensions, optical access and connection geometry. Send your drawing or labelled sketch, holder or instrument details, sample conditions and quantity if you need a different configuration from the listed SKU.
Send a product-selection enquiry and quote part number C304WS.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.









Reviews